The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 136 E 120TH PL | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS | 136 E 120TH PL | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | EXTERIOR WOOD TRIM / PEELING PAINT. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH TREADS LOOSE, RISER CRACKED, DECKBOARD WEAK, PORCH COVERED WITH SIDING, UNABLE TO CHECK JOIST LEDGER, HANDRIAL LOOSE REPAIR. PERMIT NEEDED. | 136 E 120TH PL | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | FRONT UNDERSIDE OF WOOD BROKEN AND DAMAGED WOOD PANEL. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTHEAST BASEMENT GLASS BLOCK WINDOW - BROKEN SECTIONS. | 136 E 120TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND 1ST FLOOR UNITS - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. | 136 E 120TH PL | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | NORTHEAST PORCH ENTRY DOOR AT GRADE - DOUBLE KEY LOCK. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH WALL - STEP CRACKS AND WASHED OUT MORTAR. EAST WALL - SPALLING BRICKS . | 136 E 120TH PL | COMPLAINT | FAILED | View |
PARAPET | EAST AND WEST PARAPETS - WASHED OUT MORTAR , LOOSE , MISSING , AND SPALLING BRICKS. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR COPING | SOUTH COPING - WASHED OUT MORTAR. | 136 E 120TH PL | COMPLAINT | FAILED | View |
CHIMNEY | 2 WEST CHIMNEYS - WASHED OUT MORTAR. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH STAIRWAY - GRADE TO 1ST - BROKEN AND FRACTURED CONCRETE AT LANDING. BRICK WING WALLS AND RETAINING WALL - LOOSE AND SHIFTING BRICKS WITH WASHED OUT MORTAR. | 136 E 120TH PL | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 2ND FLOOR APARTMENT - LIVINGROOM AND KITCHEN CEILINGS - FLAKING PAINT / REAR PORCH - WATER STAINS ON CEILING. | 136 E 120TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT AND REAR STAIRWAYS AT 2ND - SMOKE DETECTORS - MISSING | 136 E 120TH PL | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING | 136 E 120TH PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES ROTTED | 136 E 120TH PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION WALL OPEN JOINTS CINDER BLOCKS AND BROKEN CONCRETE | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | SOUTH PORCH ROOF ROTTED AND COLLAPSING DECKING ROTTED WOOD SPLIT TREADS RISERS RAILS 4X4 POST WOOD SPLIT SUBMIT PLANS AND PERMITS FOR REPAIRS DANGEROUS AND HAZARDOUS | 136 E 120TH PL | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | BUILDING YARD AREA HIGH WEEDS | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH EXTERIOR DOORS VENEER PEELING | 136 E 120TH PL | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH ELEVATION BURGLAR BARS | 136 E 120TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ NO RESPONSE TO CHECK DETECTOR AND CONDITIONS. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | SOUTH ELEVATION / CMU RETAINING WALL -20 X4 FT HIGH LEANING OUT AND CRACKED.PERMIT REQUIRED FOR REPAIRS TO RETAINING WALL . | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION / WOODEN FENCE - 50X3FT WEAK AND LEANING OUT . | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / 2ND FL SIDING - LOOSE AND MISSING. | 136 E 120TH PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 136 E 120TH PL | COMPLAINT | FAILED | View |
DEMO DEBRIS | FRONT PORCH - STORING HOT WTER TANK. EAST SIDE OF BUILDING - DEMO DEBRIS STORED. | 136 E 120TH PL | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | SOUTH AT ENTRY DOORS / LIGHTS - MISSING WITH WEXPOSED WIRES. | 136 E 120TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT AT 2ND FLOOR FOR BATHROOM MISSING DRYWALL. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION / SIDING - DAMAGED WITH MISSING TRIM. | 136 E 120TH PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS / WINDOW FRAMES - ROTTING WOOD WITH UNFINSHED TRIM WORK. SOME STORM WINDOWS - LOOSE AND ABOUT TO FALL TO GRAOUND. | 136 E 120TH PL | COMPLAINT | FAILED | View |
REPAIR GUTTER | EAST ELEVATION / GUTTERS - DAMAGED AND MISSING. | 136 E 120TH PL | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS / SCREENS - MISSING. | 136 E 120TH PL | COMPLAINT | FAILED | View |