Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 10:19 PM
PIN: 16241000250000
Property Address: 1253 S KEDZIE AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 100
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 72 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# ADDITIONAL INFORMATION: POST OWNER/MGMT INFO,OWNER INFORMATION,NOTHING POSTED 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL VARIOUS LOCATIONS -WASHEDOUT MORTAR 1253 S KEDZIE AVE PERIODIC FAILED View
REPLACE D&H PORCH ENTIRE PORCH GETTING ROTTED, UNKNOWN FOUNDATION STATUS.4X4 UP RIGHT COLUMNS,MISSING BOLTS ON STRINGERS,BEAM TO COLUMNS,STAIRS ARE WEAK .!! RAILINGS LOOSE , MISSING PICKETS. 1253 S KEDZIE AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR ADDITIONAL INFORMATION: SUBMIT PLANS FOR,PORCH DECK 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM UNKNOWN FOUNDATION STATUS. JOISTS ARE UNDERSIZED 2X8 SPANNED AT 10 FEET 6 INCHES,4X4 COLUMNS SUPPORTING MID LANDING ARE OVER NOTCHED,STRINGERS ARE INADEQUATELY SUPPORTED AT UP RIGHTS, RAILINGS ARE ONLY 38 INCHES HIGH. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR FLOOR ADDITIONAL INFORMATION: FLOOR,MISSING TILES,LOOSE TILES,DETERIORATED FLOOR SUPPORT,UNEVEN FLOOR 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING ADDITIONAL INFORMATION: HOLES AND CRACKS,CEILING HAS WATER DAMAGE,CEILING BUCKLED 1253 S KEDZIE AVE PERIODIC FAILED View
INSTALL DEAD BOLT LOCK MISSING KNOB 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM ADDITIONAL INFORMATION: INTERIOR STAIR SYSTEM,BROKEN STRINGERS,TREAD(S) LOOSE,TREADS) MISSING,TREADS) SPLITTING 1253 S KEDZIE AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR ADDITIONAL INFORMATION: OBTAIN PERMIT FOR,PORCH DECK REPAIR,ALL NECESSARY REPAIRS 1253 S KEDZIE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION ADDITIONAL INFORMATION: ARRANGE INSPECTION,INTERIOR 1253 S KEDZIE AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# OWNER'S I.D. IS NOT POSTED. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL WEST - WASHED OUT MORTAR JOINTS SOUTH AT GRADE LOOSE,BULGING MORTAR,SPALLED BRICKS. 1253 S KEDZIE AVE PERIODIC FAILED View
PARAPET PARAPET WALLS,SOUTH AND NORTHWEST CORNER-WASHED OUT MORTAR,OPEN JOINTS,WEEDS PROSTUDING OUT OF THE GAPS. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR WINDOW SILLS WINDOWS SILLS WEST WASHED OUT MORTAR,OPEN JOINTS 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR CORNICE CORNICE,WEST WASHED OUT MORTAR,OPEN JOINTS 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR LINTELS STONE LINTEL,ABOVE WINDOWS AT (3) SHIFTING OUTWARD ABOVE THR PUBLIC WAY.PERMIT REQUIRED FOR REPAIRS. 1253 S KEDZIE AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS WINDOW [ANES SOUTH AT (3) BROKEN. 1253 S KEDZIE AVE PERIODIC FAILED View
CUT OR REMOVE HIGH WEEDS SOUTH AND REAR HIGH WEEDS. 1253 S KEDZIE AVE PERIODIC FAILED View
PROVIDE GUTTER & DOWNSPOUT EAST MISSING DOWNSPOUT. 1253 S KEDZIE AVE PERIODIC FAILED View
PRV CAST IRON COVER FOR BASIN CENTER PORCH AREA WAY MISSING CATCH BASIN COVER,CONCEALED WITH PLYWOOD. 1253 S KEDZIE AVE PERIODIC FAILED View
REPLACE D&H PORCH CENTER PORCH ROTTED 4X4 COLUMN,TWISTED,LARGE GAPS AT SPLICE,STRINGERS ARE PULLING AWAY AT COLUMN CONNECTIONS.STAIRS ARE EXCESSIVELY PITCHED.ROTTED RAILS,BROKEN AND MISSING PICKETS.WORN,ROTTED TREADS AND RISERS.IMPROPER CONNECTIONS MOST MEMBERS ARE ONLY TOE NAILED TOGETHER WITH SEPERATION AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET SOUTH ENTRY DOOR TO CENTER PORCH OUT OF PLUMB,DOES NOT OPEN. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM EAST PORCH ENCLOSED FROM GRADE TO 1 UNABLE TO VIEW STRUCTURAL MEMBERS.COLUMNS ARE PULLING AWAY FROM THE BEAMS,GAPS ARE FILLED WITH CHAULK.FACE BEAMS ARE RIM JOISTS ARE ONLY TOE NAILED AT COLUMN CONNECTIONS,NAILS ARE PROTRIDING OUT.2ND MID-LANDING IS ONLY SUPPORTED BY A 4X4 POSTS,ONLY TOE NAILED INTO THE FACE BEAM.COLUMNS FRON (3) TO ROOF ARE STACKED AT FACE BEAM LEVEL LOOSE TREADS,NAILS ARE PROTRUDING OUT.BROKEN AND MISSING PICKETS.IMPROPER CONNECTIONS - MOST MEMBERS ARE ONLY TOE NAILED TOGETHER.PLANS AND PERMIT REQUIRED FOR REPAIRS. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM SOUTH INTERIOR STAIRWAY- MISSING HANDRAIL FROM GRADE TO 1. BROKEN GUARDRAIL AT (3).BROKEN AND MISSING PICKETS.BROKEN DECK BOARDS AT (2).ONLY PERMIT REQUIRED FOR REPAIRS. 1253 S KEDZIE AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE VIEWING DEVICES APARTMENTS- 1R AND3R AT FRONT ENTRANCES - MISSING. 1253 S KEDZIE AVE PERIODIC FAILED View
CLOSE BOX OPENINGS CIRCUIT BREAKER BOX STORE FRONT AT REAR BROKEN ACCESSPANEL,EXPOSED WIRING. 1253 S KEDZIE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR APARTMENTS - MINORS HOME ALONE,UNVERIFIED DETECTORS AND CONDITIONS.UNVERIFIED CONDITIONS IN THE BASEMENT. 1253 S KEDZIE AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING IS NOT REGISTERED FOR 2009. 1253 S KEDZIE AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# OWNER'S I.D. IS NOT POSTED. 1253 S KEDZIE AVE PERIODIC FAILED View
PROVIDE GUTTER & DOWNSPOUT EAST MISSING DOWNSPOUT. 1253 S KEDZIE AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE VIEWING DEVICES APARTMENTS- 1R AND3R AT FRONT ENTRANCES - MISSING. 1253 S KEDZIE AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR APARTMENTS - MINORS HOME ALONE,UNVERIFIED DETECTORS AND CONDITIONS.UNVERIFIED CONDITIONS IN THE BASEMENT. 1253 S KEDZIE AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING IS NOT REGISTERED FOR 2009. 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR SCREENS WINDOW SCREENS,ALL ELEVATIONS TORN AND MISSING. 1253 S KEDZIE AVE PERIODIC FAILED View
UNAPPROVED HEATING DEVICE 2ND FLR REAR USING COOKING STOVE FOR HEAT. 1253 S KEDZIE AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 2ND FLR REAR WALL UNIT HEATER HAS DISCONNECTED WIRES AND IS NOT IN SERVICE AT TIME OF INSPECTION. 1253 S KEDZIE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2ND FLR REAR SMOKE DETECTOR MISSING. 1253 S KEDZIE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS ALL ELEVATIONS 2ND & 3RD FLOOR BROKEN WINDOWS OVER PUBLIC WALKWAY, LOOSE GLASS - DANGEROUS AND HAZARDOUS. 1253 S KEDZIE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH & SOUTH WALLS HAS LOOSE/MISSING MORTAR. 1253 S KEDZIE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER POSTING. 1253 S KEDZIE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR EXIT BLOCKED BY DEBRIS/GARBAGE. ENCLOSED PORCH HAS JUNK AND DEBRIS ON STAIRS. 1253 S KEDZIE AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE USING A PROPANE HEATER FOR HEAT. 1253 S KEDZIE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING REAR CEILING BEHIND MEAT COUNTER CONSTRUCTED WITH 2X4 FRAMING IS FALLING DOWN. EAST WALL HAS MISSING DRYWALL SECTIONS. BATH WALLS ALL ELEVATIONS HAS BROKEN/MISSING DRYWALL. 1253 S KEDZIE AVE COMPLAINT FAILED View
REPLACE D&H PORCH EAST ELEVATION HAS A 3 STORY WOOD FRAMED PORCH. GRADE - 3RD FLOOR HAS MISSING GUARD/HANDRAILS, MISSING JOIST HANGERS, TREADS AT GRADE ARE LOOSE AND NOT WIDE ENOUGH, HEADERS ARE NOT ANCHORED TO BUILDING, HEADERS MISSING SUPPORT BRACKETS, MISSING PICKETS. PLANS/PERMITS REQUIRED TO FIX OR REPLACE PORCH SYSTEM. 1253 S KEDZIE AVE COMPLAINT FAILED View
REPAIR FLOOR BROKEN/MISSING FLOOR TILES THROUGHOUT 1ST FLOOR MERCANTILE SPACE. 1253 S KEDZIE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR. 1253 S KEDZIE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR. 1253 S KEDZIE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMITS FOR STRUCTURAL REPAIRS ATTEMPTED UNDER 1ST FLOOR STORE AND TO REPAIR OR REPLACE 3 STORY DANGEROUS FRAME PORCH AT REAR. 1253 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE HOT WATER TO FIXTURES NO COLD WATER TO TOILET 1ST FLOOR STORE. WATER SHUT OFF BY WATER DEPARTMENT. 1253 S KEDZIE AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER 1ST FLOOR STORE. NO WATER OR GAS SERVICE. 1253 S KEDZIE AVE COMPLAINT FAILED View
SEAL DRAIN OPENING UNUSD FIXTR 4" STACK OPEN IN RESTROOM SOUTHEAST ELEVATION 1ST FLOOR STORE. 1253 S KEDZIE AVE COMPLAINT FAILED View
KEEP FIXTUR CLEAN AND SANITARY TOILET VERY DIRTY 1ST FLOOR STORE SOUTHEAST ELEVATION. 1253 S KEDZIE AVE COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT NO PERMIT FOR PLUMBING WORK STARTED SOUTHEAST ELEVATION 1ST FLOOR. 1253 S KEDZIE AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. 1253 S KEDZIE AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND VANDALIZED POWER SERVICE - DANGEROUS. PROVIDE LOAD CALCULATIONS FOR MINIMUM 600 AMP SERVICE. 1253 S KEDZIE AVE COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING IN CEILING AND ALL IMPROPER CONNECTIONS IN CEILING. REMOVE ALL TILES TO COMPLETE A THOROUGH INSPECTION - DANGEROUS. 1253 S KEDZIE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES ON INTERIOR AND EXTERIOR OF BUILDING. 1253 S KEDZIE AVE COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL ILLUMINATION AT REAR OF STOREFRONT. 1253 S KEDZIE AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL EXTENSION CORDS THROUGHOUT STOREFRONT. 1253 S KEDZIE AVE COMPLAINT FAILED View
(18-27-110.12E) REMOVE ABANDONED CONDUITS, BOXES AND FIXTURES IN CEILING. 1253 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE NO LAVATORY IN RESTROOM 1ST FLOOR STORE. (13-196-360) 1253 S KEDZIE AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS. 1253 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE SECTION OF DOWN SPOUT MISSING(18-29-1101-2-1) 1253 S KEDZIE AVE PERIODIC FAILED View
REPAIR FENCE FENCES AT REAR MISSING BROKEN TOP RAILS.BROKEN CHAIN LINKS. 1253 S KEDZIE AVE PERIODIC FAILED View
PROVIDE NO LAUNDRY TUB OR MOP SINK 1ST FLOOR STORE. (18-29-403.1) 1253 S KEDZIE AVE COMPLAINT FAILED View
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 1253 S KEDZIE AVE COMPLAINT FAILED View
PROVIDE MISSING FIRE SEPARATION ABOVE DROP CEILING IN MERCANTILE SPACE TO RESIDENTIAL ABOVE. EXPOSED FLOOR JOISTS. (13-56-280) 1253 S KEDZIE AVE COMPLAINT FAILED View
INSTALL COVERS INSTALL COVERS TO ALL OPEN JUNCTION BOXES IN CEILING INCLUDING PANEL - DANGEROUS. 1253 S KEDZIE AVE COMPLAINT FAILED View
SYSTEM III INSTALL EMERGENCY LIGHTING SYSTEM III. 1253 S KEDZIE AVE COMPLAINT FAILED View
(18-27-210.8) INSTALL GFCI'S TO WET LOCATIONS. 1253 S KEDZIE AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE VIEWING DEVICES APARTMENTS- 1R AND3R AT FRONT ENTRANCES - MISSING. 1253 S KEDZIE AVE PERIODIC CLOSED View