The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE,UNVERIFIED COMPLAINT OF LEAK,WALL PEELING AND MOLD IN UNIT 601. | 3834 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
SEND EX. METAL LETTER | EXPOSED METAL LETTER | 3834 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
F.E. TRUSS RODS | TRUSS RODS | 3834 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
PROTECT METAL MEMBERS | PROTECT METAL MEMBERS | 3834 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE ATTIC SPIN DEVICES ON TOP OF CAR SHACKLES | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PATCH HOISTWAY SPRINKLER CHOSE | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | FINISH ELEVATOR CAB | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | SUMP PUMP IN PIT W/SINGLE GANG NON GFCI OUTLET & METAL COVER | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE TOE GUARD ON ELEVATOR CAB | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE GROUNDS FOR LINE AND LOADSIDE OF 110V AND LINE DISCONNECTED | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | COMPLETE MACHINE PROVIDING SAFE ACCESS AND HVAC W/STAIRS DOOR | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE SAFE AND CONVERT ACCESS TO SECONDARY DECK | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE FIRE EXTINGUSHER | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MACHINE ROOM LIGHTING OVER MACHINE | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE CABLE GUARDS ON DRIVE SHEAVE AND IN SECONDARY DECK CAR AND CWT 100 | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE GUARDS FOR CABLE SLOTS AND MACHINE DECK PERIMETER | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ADJUST NORMAL INSPECTION LIMITS | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE TOP OF CAR RAILING | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | MECHANCIALLY PROTECT TOP OF CAR LIGHT BULB | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROPERLY PIPE LOW VOLTAGE WIRING IN MACHINE ROOM | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |
BLANK-TEXT MUST CITE CODE SECT | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View | |
TEST G & S FRT ELE | FULL LOAD G & S 5 YEAR & 125% BRAKE HOLD | 3834 N SHEFFIELD AVE | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | SHOW RECORD OF BALANCED CAR (HUNDREDS OF LBS. OF TILE ADDED) | 3834 N SHEFFIELD AVE | PERIODIC | PASSED | View |
REPAIR EX. MET. | ENGINEER REPORT | 3834 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE GFCI OUTLETS IN MACHINE ROOM | 3834 N SHEFFIELD AVE | PERMIT | PASSED | View |