REPAIR EXTERIOR STAIR | ALL CONCRETE STEPS GRADE TO BSMT. WITH OUT HAND RAILS, 3 LOCATIONS. | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH EXTERIOR STAIR SYSTEM WITH TILTED AND UNKNOWN FOOTING DEPTH.2.-GUARD AND HAND RAILS WITH PICKETS OUT SIDE OF BOTTOM RAIL.GUARD RAILS WITH CONCRETE NAILS AT BRICK WALL.ALL CONNECTIONS TOE NAILED, MISSING ANGLE BRACKETS.3.-INTERIOR 4X4 POSTS WITH IMPROPER LAP JOINTS.4.-GRADE TO 1ST FLOOR THE FLIGHT OF STAIR WITH UNEVEN RISER HEIGHT, FROM AS LOW AS 5" AND UP TO 9".EAST EXTERIOR STAIR SYSTEM THE 2ND FLOOR LANDING WITH NEGATIVE PITCH TO DRAIN, ROTTING AND HOLES ON LANDING BOARDS.2.-GUARD AND HAND RAILS WITH THE PICKETS OUTSIDE OF BOTTOM RAIL. ALL ARE TOE NAILED, MISSING ANGLE BRACKETS AT ANCHOR AREAS.GUARD RAILS NAILED TO WALL.3.-GRADE TO 2ND FLOOR THE FLIGHTS OF STAIRS WITH UNEVEN RISER HEIGHT FROM 5 1/2" TO 10 1/2". TREAD WITH FROM 9 1/2" TO 14". 4.-UNKOWN FOOTING DEPTH UNDER COLUMNS. 5.- NORTH ENCLOSED PORTION OF PORCH WITH LOOSE BRICK WALL SECTIONS AS SEEN AT BSMT., TEMPORARY SHORING UNDER JOISTS AT THE EAST ELEVATION. 6.- ARCHITECTURAL PLANS REQUIRED TO OBTAIN PERMIT. | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST FRONT SECTION IN FRONT OF CONCRETE STEPS AND ALL OF THE REAR SERVICE WALKS WITH CONCAVED AND BROKEN SECTIONS, CAUSING TRIPPING HAZZARD AND WATER PONDING LEADING TO ICE FORMATION. | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR YARD AREA UTILIZED AS A VEHICLE PARKING AREA, SEE TIRE IMPRESSIONS CAUSING WATER TO STAGNATE. | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | CHAIN LINK FENCE WTIH BENT POSTS AND MISSING/LOOSE SECTIONS OF METAL MESH. | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR TO VERIFY OCCUPANCY AND SAFETY DETECTORS | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT AND REAR ELEVATION SERVICE WALK CRACKED AND BROKEN | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR PORCH SYSTEM GUARDRAILS UNDER 42' HANDRAILS UNDER 36' STRINGERS NOT BOLTED TO BUILDING NO FOOTINGS FOR UPRIGHTS | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
FOUNDATION, ADEQUATELY SUPPORT | NO FOOTINGS FOR UPRIGHTS | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | FRONT ELEVATION SOUTH SIDE OF BUILDING RETAINING WALLS CRACKED AND BROKEN CONCRETE | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT BEFORE PERFORMING WORK | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH AND WEST ELEVATIONS PARAPET SEVERE BULGE AND PROTRUDING BRICK OVER SECOND FLOOR WINDOWS | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | FRONT MAIN ENTRY DOOR BROKEN. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | BLDG. - NOT REGISTERED FROM 1990 THRU 2017 | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - OWNER'S I.D. SIGN - MISSING. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
ENCLSE FLOOR OPENINGS W/IHR FR | APARTMENT 2R - FURNANCE ROOM - PIPE PENETRATION HOLES. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
PROV HOT WTR TO ALL FIXTURES | APARTMENT AT 2ND FLOOR FRONT, AND ALL OCCUPIED UNITS.(18-29-607.1) (13-196-420) | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | SECOND FLOOR, FRONT AND ALL OCCUPIED APARTMENTS.(18-29-607.1) (13-12-100) | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
PRV FLUE FOR HOT WATER HEATER | CONNECT WATER HEATER FLUE PIPES TO CHIMNEY.(13-152-400) | 9635 S FOREST AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | APARTMENT 2R - BATHROOM - TUB FACUET BROKEN. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWELL - SMOKE DETECTOR - MISSING. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | APARTMENT 1R - SMOKE DETECTOR - OUT OF SERVICE. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | APARTMENT 1R - CARBON MONOXIDE DETECTOR - OUT OF SERVICE. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | APARTMENT 1R - REAR ENCLOSED PORCH AND BATHROOM - CEILING COLLAPSED, WITH WATER DAMAGE. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | APARTMENT 1R - BATHROOM AND REAR ENCLOSED PORCH - WATER LEAKING THROUGH THE CEILING; APARTMENT 2R - BATHROOM - WATER LEAKING FROM UNDER TUB TO APARTMENT 1R BATHROOM. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | ENTIRE BUILDING, INCLUDING APARTMENT 1R - MICE INFESTATION. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
INSTALL WINDOW LOCK | APARTMENT 2R - FRONT BEDROOM WINDOWS - BROKEN LOCKS. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | APARTMENT 2R - FRONT BEDROOM WINDOW SASHES - LOOSE AND FALLING OFF TRACKS. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | ENTIRE BUILDING, VARIOUS LOCATIONS - WINDOW SCREENS - MISSING. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | EAST ELEVATION - 2-STORY REAR PORCH IS IN DANGEROUS AND HAZARDOUS CONDITIONS: ENCLOSED PORTIONS OF THE PORCH AT 2 IS UNSAFE, LEANING AND SEPARATING FROM WALL, THE FLOOR IS UNLEVELED AND OUT OF PLUMB; 6X6 COLUMNS ERECTED ON CONCRETE PIERS - FOUNDATION STATUS UNKNOWN; DECKBOARDS, RISERS AND TREADS ARE LOOSE AND ROTTING, WITH NAILS LOOSE AND PROTRUDING OUT; UNUNIFORM RISER BOARDS THROUGHOUT, WITH TREADS WIDTH OF ONLY 9 INCHES; OPEN BEAM POCKETS ON WALLS; STRINGER BOARDS ARE ONLY TOE-NAILED TO COLUMNS. ENTIRE STRUCTURE IS UNSAFE, UNSTABLE AND SWAYING. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR PLATFORM | EAST ELEVATION / 1ST FLOOR REAR EXTERIOR CONCRETE PLATFORM - BROKEN AND SINKING. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | EAST REAR PORCH AT 2 - BARBECUE GRILL | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1 STAIRWAY - WINGWALL SHIFTING, WITH TOP COPING FELL OUT. | 9635 S FOREST AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | SOUTH AND WEST ELEVATION REPLACE RUSTED AND DEFECTED LINTELS ON SECOND FLOOR | 9635 S FOREST AVE | COMPLAINT | PASSED | View |