Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
SUPPLY HOT WTR MIN TEMP 120DEG HOT WATER SUPPLIED AT 65 DEG 443 W 116TH ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE USING SPACE HEATERS TO HEAT APT 443 W 116TH ST COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE WINDOWS AND DOORS NOT WEATHER TIGHT 443 W 116TH ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY NO HEAT 443 W 116TH ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR COLUMNS SET ON CONCRETE SLAB. FOUNDATION STATUS UNKNOWN. LEDGER BEAM ATTACHED TO EXTERIOR WALL WITH NAILS ONLY. RIM JOISTS ATTACHED TO COLUMNS WITH NAILS ONLY. DECK JOIST ATTACHED TO RIM JOISTS WITH NAILS ONLY. RAIL SECTIONS ARE ONLY 34" HIGH. RAIL SECTIONS ATTACHED TO EXTERIOR WALL AND POSTS WITH NAILS ONLY. RAILS SECTIONS ARE LOOSE. STRINGERS ATTACHED TO COLUMNS WITH NAILS ONLY. PERMIT ONLY, NO PLANS REQUIRED TO REPAIR WEST EXTERIOR STAIRS. 443 W 116TH ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING KITCHEN CEILING WATER DAMAGED. 443 W 116TH ST COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE REAR DOOR NOT SEALED. AIR INFILTRATION. 443 W 116TH ST COMPLAINT FAILED View
REPAIR DOOR, INT. BEDROOM DOOR BROKEN OFF HINGES. 443 W 116TH ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM HANDRAIL MISSING. 443 W 116TH ST COMPLAINT FAILED View
MICE/RODENTS MICE DROPPINGS. 443 W 116TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. 443 W 116TH ST COMPLAINT FAILED View
PROVIDE FURNACE OUT OF SERVICE AT TIME OF INSPECTION. NO GAS SERVICE. HOT WATER NOT PROVIDED AT TIME OF INSPECTION. 443 W 116TH ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNERS ID SIGN NOT POSTED. 443 W 116TH ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NOT WATER PROVIDED AT 62 F. NO GAS SERVICE. NO HOT WATER. 443 W 116TH ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE BATHROOM TOILET BROKEN. 443 W 116TH ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS KITCHEN WINDOW BROKEN AND BOARDED. 443 W 116TH ST COMPLAINT FAILED View
COVER OUTLETS AND JBS METER SOCKET OPEN.METER MISSING. 443 W 116TH ST COMPLAINT FAILED View