INSTALL SMOKE DETECTORS | INTERIOR STAIRWAY NO SMOKE DETECTOR, ALSO BASEMENT AREA | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FLOOR REAR WINDOW BROKEN PANE | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT IRON FENCE ERECTED WITH OUT PERMIT | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | AT REAR, GANGWAY, BASEMENT FULL OF JUNK AND DEBRIS THRU OUT WITH HOUSE HOLD MATERIAL | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCE FOR ELECTRICAL PANES | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THRU OUT 1ST AND 2ND FLOOR DWELLING UNITS- LIVING ROOMS, DINING ROOMS, BEDROOMS | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
ARMORED CABLE | REPLACE DETECTIVE ARMOURED CABLE THRU OUT BASEMENT AREAS | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER COVERS FOR JUNCTION BOXES BY PANEL LOCATION AND THRU OUT AREAS OF LAUNDRY ROOM AND FRONT AREA OF BASEMENT | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
PROVIDE WEATHER PROOF TYPE BOXES FITTINGS AND LITE FIXTURES FOR EXTERIOR LITE FOR PORCH AREAS AND SIDE ENTRANCE TO BASEMENT AREA - 18.27. 110. 11 | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View | |
SECURE RACEWAY | PROPERLY SUPPORT CONDUIT RUNS ON EXTERIOR EAST SIDE AND REAR OF BUILDING | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
MAINTAIN REQUIRED CLEARANCES FOR SERVICE DROP CONDUCTORS SERVICE IS WITHIN REACH 18.27-230.24 | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View | |
NO PERMIT WIRING | BASEMENT REMODEL NO PERMITS - ELECTRICAL -INSTALLATION | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR COUNTER TOP AREAS AND BATHROOMS OF 1ST AND 2ND FLOOR UNITS - 18.27.210.8 | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | ALL APT ENTRY DOOR MISSING VIEWING DEVICE | 4043 W LEXINGTON ST | COMPLAINT | PASSED | View |