The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR CORNICE | OPEN CORNICE JOINTS VARIOUS LOCATIONS- COURT YARD. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | SOME LINTELS IN COURT YARD AND SOUTH ELEVATIONS AT VARIOUS LOCATIONS- RUSTING, FLAKING PAINT. SOME SAGGING LINTELS. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | OPEN SILL JOINTS VARIOUS LOCATIONS- COURT YARD. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | NORTH WEST AND NORTH EAST 6X6 COLUMNS SUPPORTING ENCLOSURES ARE ROTTING AT BASE. OBTAIN PERMIT AND REPLACE. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR, NO ACCESS GATED PORCHES. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | UNDERSIDE OF NORTH EAST ENCLOSURE- EXPOSED JOISTS AND SUBFLOORING, NO FIRE SEPARATION. UNDERSIDE OF NORTH WEST ENCLOSURE IS PLYWOOD ONLY, INSUFFICIENT FIRE SEPARATION. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | 1358 W GREENLEAF AVE | PERMIT | FAILED | View | |
SEE INSPECTOR COMMENTS | 1358 W GREENLEAF AVE | PERMIT | FAILED | View | |
OPEN | 1358 W GREENLEAF AVE | PERMIT | FAILED | View | |
REPAIR EXTERIOR WALL | FRONT ELEVATION /EXTERIOR WALL AT 1362 W ENTRANCE - FRACTURED LIMESTONE SECTIONS. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION /WINDOW LINTELS AT MAIN COURTYARD - LINTELS RUSTED WITH FLAKY, PEELING PAINT AT VARIOUS LOCATIONS. PERMIT REQUIRED FOR REPAIRS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | BUILDING THROUGHOUT - WINDOW LINTELS AT VARIOUS LOCATIONS HAVE BEEN REPLACED WITHOUT PERMIT ON FILE FOR SAID LINTEL REPAIRS/REPLACEMENT. PERMIT NOW REQUIRED FOR LINTEL REPLACEMENTS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF NO WORKING SMOKE DETECTORS. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | FRONT ELEVATION /WINDOW SILLS - OPEN MORTAR JOINTS. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | FRONT ELEVATION /MAIN COURTYARD WINDOWS AT 2ND AND 3RD FLOORS - COVERED WITH PLYWOOD PANELS. | 1358 W GREENLEAF AVE | PERIODIC | FAILED | View |