Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE | A TEST KIT FOR TESTING REFRIGERANT MONITORS, SERVICING EAST & WEST PENTHOUSES, CALL 312-446-5315 & ASK FOR INSPECTOR OSBORNE TO SCHEDULE TEST DATE. (SEC.13-12-100,13-192-760) | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN & POST OCCUPANCY CARDS FOR THE FOLLOWING ROOMS: WATER TOWER-CONCOURSE LEVEL, PICASSO, REGENCY BALLROOM B/C, A & D, OGDEN SUITE; AND DIAGRAM FOR 3RD FLOOR ROOMS, CONCOURSE CARD LOBBY LEVEL | 151 E WACKER DR | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | (18-27-700.6) - RESTORE AND REPAIR EMERGENCY LIGHTING SYSTEM TO OPERABLE CONDITION - EAST AND WEST TOWERS - TRANSFER SWITCHES IN BOTH BUILDINGS FAILED- | 151 E WACKER DR | COMPLAINT | PASSED | View |
RESTORE GENERATOR | (18-27-701.90 - PROPERLY PROVIDE VENTILATING AIR EXHAUST FOR GENERATORS - WEST TOWER EXHAUST AND 1 DAMPER FAILED - | 151 E WACKER DR | COMPLAINT | PASSED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN & POST OCCUPANCY CARDS FOR REGENCY CD, REGENCY ABC AND PRE FUNCTION FOR CRYSTAL FOYER. | 151 E WACKER DR | PERIODIC | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | 151 E WACKER DR | PERMIT | PASSED | View | |
POST APPROVED OCCUPANCY CARD | POST ORIGINAL OCCUPANCY PLACARDS ON ALL ASSEMBLY ROOMS (COPIES OR VANITIES CARDS POSTED) | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST ORIGINAL OCCUPANCY PLACARDS IN ALL ASSEMBLY ROOMS - (VANITY CARDS POSTED)- SHOW DIAGRAMS - WIP - WORKING W/ BILL DORTERTY | 151 E WACKER DR | PERIODIC | FAILED | View |
ARRANGE FOR RE-INSPECTION | TEST REFRG. MONITORS | 151 E WACKER DR | PERMIT | FAILED | View |
POST APPROVED OCCUPANCY CARD | MISSING OCCUPANCY CARDS FOR STETSON ROOMS A THRU G, COMBINATION OF ROOMS B AND C. (COPIES POSTED FOR A THRU G)(NOT POSTED FOR COMBINATION OF ROOM B-C) | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST ALL MISSING OCCUPANCY PLACARDS FOR MEETING.DINING AND BANQUET SPACES OR OBTAIN DUPLICATE PLACARDS FROM CITY HALL | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | OCCUPANCY CAPACITY CARDS ARE REQUIRED AT HEALTH CLUB, REGENCY C&D, A,B&C, B,C &D, 2ND FLOOR BAR (LOUNGE & GALLERY). | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST MISSING OCCUPANCY PLACARD AT THE FOLLOWING ROOM. 1) STETSON MISSING OCCUPANCY PLACARD AT THE FOLLOWING ADDRESS 2) REGENCY BALLROOM CONFIGURATION B,C,&D. 3)REGENCY BALLROOM CONFIGURATION C&D 4) REGENCY BALLROOM CONFIGURATION A,B,&C 5)WRIGLEY ROOM 6)SKYWAY BRIDGE | 151 E WACKER DR | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | FINISH 3 MORE ESC. MODS (THIS ONE COMPLETE) | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | ENCLOSE TRUUSS- MUST BE FIRE PROOF | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | FINISH FLOOR AT ENTRANCES AND EXIT | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | PROVIDE ALL BARRICADES | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | PROVIDE CODE DATA TAGS (PLATES) AT ALL KEY SWITCH START LOCATIONS | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | INSTALL MISSING GLASS BALLISTRADE ON ESCALATOR | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | COMPLETE SAILINGS AND BARRICADES AROUND ESCALATIORS | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | LOCK OUT "SLEEPMODE" CONTROLLERS ON ALL ESCALATORS EQUIPTED WITH DEVICE | 151 E WACKER DR | PERMIT | PASSED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN AND POST AN OCCUPANCY PLACARD FOR NEW HEALTH CLUB ON 2ND FLOOR BLUE LEVEL AND POST MISSING EXISTNG PLACARDS FOR CRYSTAL BALLROOM PATIO 1ST FLOOR GREEN LEVEL, REGENCY BALLROOMS,A&B,B&C,C&D,A,B&C,B,C&D LOWER LEVEL 2 GOLD AND STETSON MEETING ROOMS A,D,E,F,G,AND F&G LOWER LEVEL 3 PURPLE. | 151 E WACKER DR | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | PROVIDE FIRE RATED PIT | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | REPAIR TOP LANDING EGRESS AREA ESC #31+ #32 | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | REPAIR GLASS BALUSTRADE ON ESC 31-34 | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE (1) FIRE GIB FOR EACH HOISTWAY DOOR PANEL | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLETE INSTALLATION TO BE ABLE TO TEST UNINTENTIONAL MOTION. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY PROTECT EXPOSED COMMUNICATION CABLES IN HOISTWAY | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL ALL ELECTRICAL COVERS IN HOISTWAY AND MACHINE ROOM | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CONVIENCE GFEI OUTLETS IN MACHINE ROOM | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SAFE AND CONVIENT ACCESS TO PITS OF ELEVATOR#4-6 WEST. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | IDENTIFY DISCONNECTS CAB LIGHTS CAR NO.VOLTAGE. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PIT PLATFORMS ALL PITS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE FIRE SPRINKLES/PIPES AND ABANDONED PLUMSING FROM MACHINE ROOM | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE FIRE SPRINKLES/PIPES AND ABANDONED PLUMSING FROM MACHINE ROOM. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CAR NUMBERS ON ALL HOISTWAY ENTRANCES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PHOTOGRAPHS AT ALL HALL STATIONS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | UPON COMPLETED SCHEDULE, FIREMAN'S SERVICE. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADJUST TENSION ON COMPUTERIZING CABLES. | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH HOISTWAYS ELEVATORS 4E + 5E | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LEDGES OF HOISTWAY CANTS BROKEN | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 17TH FLOOR ELEVATOR #4E SPIRATOR CABLE | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BETWEEN 1-2 FLOOR PLACING PIPE IN HOISTWAY REAR | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FIRE STOPS OWE ON EDCH DOOR PANEL | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REINFORCE SUPPORT OF TOE GUARDS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPLACE MISSING DOOR GIBBS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELECTRICAL BOX FOR TOP ACCESS KEY SWITCHES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ESCUSSIONS ON ELEVATOR 5E | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MACHINE ROOM DOOR HANDLE UNLOCKABLE | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LIGHTING AND GFEI OUTLETS IN EAST MACHINE ROOM | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LIGHTING AND GFEI OUTLETS IN SECONDARY AREA | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SMOKE DETECTOR IN SECONTARY AREA + REMOVE FALSE CEILING. | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MISSING DOOR GUBBS 4E +5E | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | OATCH MACHINE ROOM AND SECONDARY AREA | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | METAL CODE DATA PLATES ON CONTROLLERS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE LOCK FOR SECONDARY AREA | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BALANCE LOADS ON ELEVATOR 30 DAY TEMP. REINSPECTOR 4E+5E | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH MACHINE ROOM AND SECONDARY AREA | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY PROTECT ALL WIRING IN MACHINE ROOM PULL THROUGH CONDUIT | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SPRATORS ON ALL HOISTWAY DOORS OPPOSITE OF DRIVING PANEL | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR BUFFER SWTICH ON ELEVATOR 5W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CALL CANCEL BUTTON ELEVATOR #7W | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ALARM BELL | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLETE CAB MODERNIZATION ELEVATOR #7W AND # 8W | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM FIRE SERVICE TESTING PHASE I AND II | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR HALL PI AND HALL LANTERN #12 | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST FIRE RECALL & EMERGENCY POWER | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH HOISTWAY | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MACHINE ROOM GFI'S | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FINISH DRILLING ESCUTCHEONS IN HOISTWAY DOORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE SPRINKLER PIPE FROM MACHINE ROOM | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GFI RECEPTICLE IN ALL MACHINE SPACES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ADEQUATE LIGHTING IN ELEVATOR MACHINE ROOM | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE FIRE ANGLES ON ALL LINGING DOORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PIT SUMP HOLE & PUMP | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ADEQUATE LIGHTING IN ELEVATOR PIT | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GFI RECEPTECLE IN ELEVATOR PIT | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST EMERGENCY POWER | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST FIRE SERVICE | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | IN CASE OF FIRE PICTOGRAPHS AT EACH LANDING | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST FIRE RECALL AND EMERGENCY POWER | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MACHINE ROOM GFI'S | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | ESCALATORS 29+30 FINISH INSTALLING DECKING AND SIGNAGE. | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL FIRE GIBS ON HOISTWAY DOORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST ALL FAID'S | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FURNISH MEANS TO ACCESS BOTTOM OF CAR. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR FIREMANS SERVICE ELEVATOR 8E PHASE I & II | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH HOISTWAY ELEVATOR # 1E | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR #1E OKAYED FOR TEMP. USE | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | INSTALL INNER PANELS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | INSTALL FLOOR PLATES BOTH ESCALATORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL ALL HOISTWY COVERS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR FIREMANS SERVICE PHASE I & II KEY SWITCHES MUST BE KEYED ALIKE THROUGH OUT BUILDING | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR CONTROL PANEL (LOBBY PANEL) JEWEL DOESN'T ILLUMINATE FOR FIREMANS SERVICE | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR CONTROL PANEL PHASE I AUXILARY KEY SWITCH COLLAR MUST BE RED | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LIFT NET SCREEN ON EAST LOBBY ELEVATOR CONTROL PANEL SHOULD REFLECT A REALISTIC DEPICTION OF ELEVATOR LOCATIONS AND NUMBERING SEQUENCES.IE: EAST BUILDING IS WEST, CAR NUMBERS ON PASSENGER EAST CARS ARE IN WRONG ORDER | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CAR NUMBERS AND BRAILLE PLATES ON ALL HOISTWAY ENTRANCES AT ALL LANDINGS#1E-#12E ELEVATORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE A PLATE AT THE ELEVATOR CONTROL PANEL WITH A DIAGRAMIC DEPICTION OF ELEVATOR LOCATIONS THROUGH OUT BUILDINGS | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS #11E & #12E DO NOT RESPOND TO LOBBY FAIDS ALL ELEVATORS SERVING THE FLOOR SHALL REPOND | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE EXIT DIRECTIONAL SIGNAGE ON 3RD FLOOR ELEVATOR LOBBY TO ACCOMIDATE ALTERNATE FLOOR RECALL | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR #10E DOESN'T RESPOND TO ALTERNATE FLOOR ON LOBBY FAID TRIP. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ALL ELECTRICAL COVERS IN HOISTWAYS, MACHINE ROOMS, AND PITS. ALL ELEVATORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MECHANICAL PROTECTION ON ALL LIGHT BULBS IN MACHINE ROOM, HOISTWAY, PITS...ALL ELEVATORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CANT LEDGES ON HOISTWAY DOOR RETURN WALLS. CARS 10W & 11W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH HOISTWAYS,ELEVATOR #10 CINDER BLOCK AT LOWER FLOORS. HOLES IN ELEVATOR #9 | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SHAFT BOARD MISSING AT 2ND FLOOR REAR OF HOISTWAYS ELEVATOR #10. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE STOP SWITCH AND CABLE GUARDS IN SECONDARY AREA OF ELEVATOR #10 | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ALL ELECTRICAL COVERS IN HOISTWAYS, MACHINE ROOMS, AND PITS. ELEVATORS #9 & #10 | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MECHANICAL PROTECTION ON ALL LIGHT BULBS IN MACHINE ROOM, HOISTWAY, PITS...ELEVATORS #9 & #10 | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | STENCIL FLOOR NUMBERS ON HOISTWAY SIDE OF HOISTWAY DOORS ELEVATOR #10 | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GFCI CONVENENCE OUTLETS IN ALL MACHINE SPACES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PIT WORKING PLATFORM WITH PERMANENT LADDER IN ELEVATOR PIT ELEVATOR #10 | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PIT ALARM BELLS | 151 E WACKER DR | PERMIT | FAILED | View |
POST APPROVED OCCUPANCY CARD | OCCUPANCY CARDS REQUIRED AT 2ND BLUE, REGENCY BALLROOM,2ND GOLD AND CRYSTAL BALLROOM PATIO. | 151 E WACKER DR | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE RESTRICTOR ANGLES THROUGH OUT HOIST WAY. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE METAL CODE DATA PLATES ON CONTROLLERS AND CROSSHEAD DATA PLATES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | FINISH FLOOR PLATES | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | FINISH AND TEST UP ESCALATOR - CONCOURSE TO WEST LOBBY | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE STOP SWITCH AND CABLE GUARDS IN SECONDARY AREA OF ELEVATORS. ALL ELEVATORS. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | STENCIL FLOOR NUMBERS ON HOISTWAY SIDE OF HOISTWAY DOORS ELEVATOR. ALL ELEVATORS | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SHOW CAR NUMBER ON CAR TOP, TOE GUARD, ALL MACHINE ROOM AND SECONDARY EQUIPMENT AND BACK OF PIT WALL. ALL ELEVATORS. | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CANT LEDGES ON HOISTWAY DOOR RETURN WALLS. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH WALL BETWEEN 2ND. & 3RD. FLOORS. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM ASCENDING OVERSPEED TEST. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST PHASE 1 & 2. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL ALL MISSING FACIA. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PERMANENT ACCESS TO BOTTOM OF CAR. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL GFCI & LIGHTING IN SECONDARY. CAR 10W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL GFCI,STOP SWITCHES & LIGHTING IN SECONDARIES OF WEST ELEVATORS. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADJUST BOTTOM ACCESS CAR STOP. CAR 11W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | RELOCATE PIT STOP SWITCH TO 47" ABOVE PIT FLOOR. CAR 11W | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GOV./SAFETY TEST TAG. ALL ELEVATORS. | 151 E WACKER DR | PERMIT | FAILED | View |
POST APPROVED OCCUPANCY CARD | REPLACE MISSING OCCUPANCY CARDS FOR REGENCY C&D COMBINATION AND A,B&C COMBINATION AND FOR THE SKYWAY BRIDGE. | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | REPLACE MISSING OCCUPANCY CARDS FOR REGENCY C&D COMBINATION AND A,B&C,BC&D COMBINATION AND FOR THE SKYWAY BRIDGE. | 151 E WACKER DR | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE EMERGENCY POWER LIGHT IN ALL AELEVATOR LOBBIES. ASME A17.1-2007 SECT. 2.27.2.3 | 151 E WACKER DR | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PERFORM 1 YEAR FULL LOAD PRESSURE TEST ON HYDRAULIC FREIGHT ELEVATOR AND TAG VALVE RULE 1005.2A. 18-30-010,13-20-120 | 151 E WACKER DR | PERIODIC | PASSED | View |
TEST G & S ALL ELE | PERFORM 1 YEAR GOVERNOR AND SAFETY TEST AND TAG GOVERNOR ACCORDINGLY RULE 1002.2B EV007181 | 151 E WACKER DR | PERIODIC | PASSED | View |
POST APPROVED OCCUPANCY CARD | OCCUPANCY CAPACITY CARDS ARE REQUIRED AT HEALTH CLUB, REGENCY C&D, A,B&C, B,C &D, 2ND FLOOR BAR (LOUNGE & GALLERY). | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST ALL MISSING OCCUPANCY PLACARDS FOR MEETING.DINING AND BANQUET SPACES OR OBTAIN DUPLICATE PLACARDS FROM CITY HALL | 151 E WACKER DR | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | REPLACE MISSING OCCUPANCY CARDS FOR REGENCY C&D COMBINATION AND A,B&C COMBINATION AND FOR THE SKYWAY BRIDGE. | 151 E WACKER DR | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ESCALATOR | COMPLETE INTERDECKING | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ESCALATOR | STEP SKIRT INDEX LATER DATE | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FINISH CAB FLOORING #7 AND #8 | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST PHASE I AND II. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS #7E, #8E, #9E, & #10E COP FLOOR IDENTIFICATION MUST REFLECT ACTUAL FLOOR NUMBER DESIGNATIONS | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | STENCIL HOISTWAY DOORS AND CROSSHEAD. | 151 E WACKER DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH HOISTWAY | 151 E WACKER DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BEVEL LEDGES | 151 E WACKER DR | PERMIT | PASSED | View |