Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | MISSING OWNERS I.D SIGN | 1730 W ERIE ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED OCCUPANCY AND DETECTORS | 1730 W ERIE ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | 2ND, 3RD FLOOR AND FRONT INTERIOR STAIRWAY - NO RESPONSE FOR 2016 ANNUAL INSPECTION TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 1730 W ERIE ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY OPEN WOOD PORCH: OVER NOTCHED COLUMNS WITH BEAM FIRE CUT HAPPANING 6" AWAY FROM RIM JOIST NOTCH.; COLUMN HALF-LAP SPLICE CONNECTION IS ONLY 12" LONG AND FASTENED WITH TWO BOLTS ONLY.; STRINGERS , RAILING TIES AND END POST TO WALL ARE FASTENED WITH NAILS OR TOE SCREWED ONLY.; TREADS ARE ONLY 9-1/4" WIDE. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 1730 W ERIE ST | PERIODIC | FAILED | View |
RELOCATE SMOKE DETECTOR | 1ST FLOOR APT. - SMOKE DETECTOR MOUNTED APROX. 20" BELOW THE CEILING. | 1730 W ERIE ST | PERIODIC | FAILED | View |