Last Modification Date: 2024-08-30 @ 3:57 PM
PIN: 17194210390000
Property Address: 2014 S ASHLAND AVE
City - Zip: CHICAGO - 60608
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77141
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR 2-3RD FLRS FRONT BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR 2-3RD FLRS FRONT BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View
REPLACE D&H PORCH REAR 3 STORY WOOD PORCH WITH ATTIC ACCESS, UNKNOWN COLUMN FOOTINGS, ALL WOOD ON PORCH IS ROTTED AND DAMAGED THRU OUT, MID LANDING 2 AND 3RD FLOOR THE FLOOR JOIST HAVE PULLED OUT OF THE WALLS AND THE 2X6 SUPPORT BEAM HAS SPLIT, ALL COLUMNS HAVE ROTTED WOOD SECTIONS, ALL FIRE CUTS ON THE COLUMNS FOR THE BEAMS ARE ROTTED AWAY. DANGEROUS. PORCH HAS BEEN POSTED. PLANS AND PERMITS FOR REPLACEMENTTENANTS NOTIFIED 2014 S ASHLAND AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR 1ST FLOOR REAR BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR 1ST FLOOR REAR BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View
REPLACE D&H PORCH 3 STORY REAR WOOD PORCH WITH ATTIC ACCESS HAS MUCH ROTTED WOOD, BEAMS ARE PULLING AWAY FROM COLUMNS WITH ONE USING A 6X6 SEPARATE COLUMN FOR SUPPORT,STAIRS FROM 2ND FLOOR LEADING TO THE ATTIC THE STRINGER HAS SEPARATED AND IS NOT BEING SUPPORTED, DANGEROUS - POSTED - TENANTS NOTIFIED- PLANS AND PERMIT FOR REPLACEMENT 2014 S ASHLAND AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT ENTRANCE, FOR REAR BUILDING, WOOD STAIR ALL WOOD AS DAMAGED AND ROTTED, NO FITTINGS, MISSING HANGERS FOR LANDING JOIST, PERMIT REAR BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View
STOP/REMOVE NUISANCE MUCH JUNK AND DEBRIS IN CENTER AND REAR YARDS 2014 S ASHLAND AVE COMPLAINT PASSED View
REPAIR DOOR HARDWARE MISSING PASSAGE LOCK2ND FLOOR FRONT BUILDING 2014 S ASHLAND AVE COMPLAINT PASSED View