Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP ALL WORK UNTIL PROPER PLANS AND PERMIT HAVE BEEN OBTAINED. SEC. 13-32-035; 13-12-035 | 33 W MONROE ST | COMPLAINT | FAILED | View | |
PLANS & PERMITS REQ - CONTRCTR | FOR OFFICE BUILDOUT OF 10TH FLOOR. | 33 W MONROE ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | 10TH FLOOR OFFICE BUILDOUT AND WITHOUT PERMIT. | 33 W MONROE ST | COMPLAINT | FAILED | View |
STOP ALL WORK UNTIL PROPER PLANS AND PERMIT HAVE BEEN OBTAINED. SEC. 13-32-035; 13-12-035PERMIT #100163883 ISSUED 04-10-07 (PSO FEES PAID) | 33 W MONROE ST | COMPLAINT | CLOSED | View | |
PLANS & PERMITS REQ - CONTRCTR | FOR OFFICE BUILDOUT OF 10TH FLOOR.PERMIT #100163883 ISSUED 04-10-07 (PSO FEES PAID) | 33 W MONROE ST | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | 10TH FLOOR OFFICE BUILDOUT AND WITHOUT PERMIT.PERMIT #100163883 ISSUED 04-10-07 (PSO FEES PAID) | 33 W MONROE ST | COMPLAINT | CLOSED | View |
ARRANGE FOR RE-INSPECTION | NO VENT LINE | 33 W MONROE ST | PERMIT | PASSED | View |
ARRANGE FOR RE-INSPECTION | NO VENT LINE | 33 W MONROE ST | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | (VT 7022) JOINTS AND CONNECTIONS TAPES AND MASTICS USED WITH FLEXIBLE AIR DUCTS SHALL BE LIFTED AND LABELED IN ACCORDANCE WITB UL 181B | 33 W MONROE ST | COMPLAINT | PASSED | View |
OPEN TYPE VIOLATION | (VT 7024) BALANCING DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN THE BRANCH DUCT OR AT EACH INDIVIDUAL DUCT REGISTER, GRILL OR DIFFUSER | 33 W MONROE ST | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 13-20-290 ARRANGE FOR COMPLETE PERMIT INSPECTION | 33 W MONROE ST | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 33 W MONROE ST | PERIODIC | PASSED | View | |
PROVIDE OUTSIDE AIR SUPPLY | [PROVIDE OUTSIDE AIR SUPPLY (18-28-403.3) | 33 W MONROE ST | PERIODIC | PASSED | View |
MAINTAIN MECH. VENT SYSTEM | MAINTAIN MECHANICAL VENTILATION SYSTEM IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUATE VENTILATION DURING HOURS OF OCCUPANCY (18-28-102.3 CHECKED OUTSIDE AIR DAMPERS ON SEVERAL FLOORS NO ALL DAMPERS WERE OPERABLE AT TIME OF INSPECTION | 33 W MONROE ST | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CAULM MACHINE ROOM HOLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | RECALIBRATE GOVERNOR AND IF NEED BE, REPLACE. IF REPLACED, RETEST WITH CITY OF CHICAGO. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #16: RESCHEDULE FULL LOAD DROP TEST WITH CITY OF CHICAGO. NO USE | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CAP/REMOVE SPRINLERHEADS IN SECONDARY OR REPLACE ELECTRICAL PIPE AND FITTINGS WITH LIQUID TIGHT | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #16: RECALIBRATE GOVERNOR AND IF NEED BE, REPLACE. IF REPLACED, RETEST WITH CITY OF CHICAGO. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #17: CANT 1ST FLOOR REAR WALL THAT HAS BEEN REMOVED | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE FLUSH MOUNT TOP ACCESS KEY SWITCH | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE AND ETCH CODE YEAR FOR CODE DATA PLATE | 33 W MONROE ST | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2031) 13-16-070 WORKMANSHIP TO MEET INTENT OF BUILDING PROVISIONS OF THIS CODE | 33 W MONROE ST | COMPLAINT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #6: PROVIDE OVERHEAD GRATING IN HOISTWAY WHERE LOADWEIGH CABLE IS LOCATED. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: STENCIL ELEVATOR ID ON: CROSSHEAD, TOE GUARD, CONTROLLER, TRANSFORMER | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #6: REPAIR EMERGENY LIGH AND ALARM BELL THAT DOES NOT OPERATE WITHOUT 110V POWER | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE RUNBY SIGN AND COMPLETE DATA. AFFIX NEAR COUNTERWEIGHT BUFFER | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PLUG ALL UNUSED HOLES IN MACHINE DECK FLOOR | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE RED AND WHITE DIAGONAL STRIPES IN PIT WHERE COMPENSATION CHAINS ARE LOCATED | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: CAULK HOWISTWAY CALL BUTTON BOXES AND ACCESS KEY SWITCHES WITH 2HR FIRE RATED MATERIAL | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE 19 FOOT CANDLES OF ADDITIONAL CARTOP LIGHTING THAT IS ACCESSIBLE FROM ANY POINT OF THE CARTOP | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE HOISTWAY DOOR FIRE TABS AT EVERY LANDING | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL: PROVIDE AND MOUNT ABC FIRE EXTINGUISHERS IN CONTROL ROOMS AND MACHINE ROOMS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL: PROVIDE CABLE GUARDS AROUND CAR AND COUNTERWEIGHT CABLES IN SECONDARY. ALSO, STENCIL ELEVATOR ID ON COVERS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE CODE DATA PLATE ON CONTROLLER. ETCH/STAMP CODE YEAR IN AFFECT | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL: REMOVE CONTROL ROOM/MACHINE ROOM HEAT DETECTORS AND PROVIDE PROGRAMMABLE/ADDRESSABLE SMOKE DETECTOR | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #15 & #16 ELEVATORS: REPLACE HOIST CABLES AND GOVERNOR CABLES AND PROVIDE ROPE DATA TAGS PRIOR TO FINAL. MUST BE TESTED WITH THE CITY OF CHICAGO. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL PITS: REMOVE GROUND CABLE IN PIT ATTACHED TO RAILS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CAULK MACHINE ROOM HOLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: STENCIL LANDING NUMBERS ON HOISTWAY WALL OF BLIND HOISTWAY | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE CODE COMPLIANT PERMANENT WORKING UNDERSIDE PLATFORM WITH PERMANENT FIXED LADDER AND CODE COMPLIANT RAILING | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE CODE COMPLIANT TOE GUARD | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE ALTERNATE PIT STOP SWITCH TO BE LOCATED AT UNDERSIDE WORKING PLATFORM | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PLUG UNUSED HOISTWAY DOOR HOLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: MOVE ESCUSSIONS DOWN TO MEET CODE REQUIREMENTS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE MACHINE BEDPLATE GUARD WHERE LOADWEIGH CABLE AND ROPE GRIPPER IS LOCATED. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #6: ADJUST TOP FINAL LIMIT | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE 10 FOOT CANDLES OF LIGHTING FROM ANY POINT OF CARTOP | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE ALL NON GFI OUTLETS IN MACHINE ROOM | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE HANDRAIL ON BOTH SIDES OF DECK LADDER IN MACHINE ROOM NEAR ELEVATOR 2. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR 2: MOVE PIT STOP SWITCHES ADJACENT TO PIT LADDER AND TEST | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE ROPE DATA TAGS FOR NEWLY INSTALLED CABLES IN ACCESSIBLE PLACE | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR 2: PROVIDE RELAY TO TIE IN FIRE SERVICE AND TEST PHASE I FOR TEMP USE | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PLUG ALL UNUSED HOLES IN MACHINE DECK FLOOR AND MACHINE ROOM WALLS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR 2: REPLACE WORN AND IRREPARABLE COUNTERWEIGHT SHEAVE. NO USE - RESCHEDULE FULL LOAD DROP FOR COUNTERWEIGHT AND CAR; 125% LOAD; ACO TEST AFTER REPLACED FOR TEMP USE OF ELEVATOR | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATOR 2: PROVIDE CODE COMPLIANT TOE GUARD | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: TEST CARD READER ONCE ACTIVATED WITH PHASE II | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #6: REPAIR EMERGENY LIGHT AND ALARM BELL THAT DOES NOT OPERATE WITHOUT 110V POWER | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE 10 FOOT CANDLES OF LIGHTING TO REFLECT FROM ANY POINT OF CARTOP | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE ROPE DATA TAGS FOR NEWLY INSTALLED CABLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PER CODE PROVIDE CAT1/5 TEST SHEETS AND AND GOVERNOR TEST TAGS FOR ALL ELEVATORS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE MACHINE BEDPLATE GUARD WHERE LOADWEIGHT CABLES AND ROPE GRIPPER IS LOCATED. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE AND ETCH CODE DATA PLATE TO REFLECT CODE YEAR FOR ALTERATION (2016) | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LOWRISE: PROVIDE HANDRAIL/HANDBAR ON BOTH SIDES OF DECK LADDER IN MACHINE ROOM. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE ELEVATOR IDENTIFICATION ON JAMB AT EVERY LANDING | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | EVERY MACHINE ROOM AND PIT: INSTALL GFCI OUTLETS AND REMOVE ALL GENERAL DUTY OUTLETS IN MACHINE ROOM | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE CARTOP HANDRAIL | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: REPAIR TOP OF CAR GREENFIELD FOR BALLAST | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: PEG UNUSED ESSCUSSION HOLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE FIRE SERVICE INSTRUCTIONS BEHIND PHASE II PANEL IN CAR | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: TAPE COUNTERWEIGHT CABLE TAIL ENDS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE PERMANENT WORKING PIT PLATFORM WITH ACCESSIBLE STOP SWITCH | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE "DANGER COUNTERWEIGHT" SIGNS ADJACENT TO COUNTERWEIGHT BUFFER | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE FEOK1 KEY IN FIRE SERVICE BOX | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: REMOVE STINGER OR SHORTEN CABLES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: REPAIR PHASE II FIRE SERVICE OPERATION. WHILE ON PHASE II RETURNS TO NORMAL OPERATION ONCE PHASE I IS TURNED OFF. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE FLUSH MOUNT CONTROLS BEHIND C.O.P. PANEL OR PIPE/GREENFIELD EXPOSED WIRES | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MACHINE ROOM DOOR SIGN ON OR ADJACENT TO OUTER DOOR | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE 19 FOOT CANDLES OF LIGHTING OVER MACHINES AND CONTROLLERS TO PROJECT LIGHT AROUND WORKING AREAS IN MACHINE ROOM | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE MACHINE CABLE GUARDS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE CODE DATA PLATE | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS: PROVIDE DISCONNECT SOURCE FEED LABELS; WARNING LABELS; VOLTAGE LABELS | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #7: NO USE - RESCHEDULE COUNTERWEIGHT SAFETY TEST. EMPTY/FULL LOAD TEST GOOD. | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL TOE GUARD AND ALL OTHER RELATED EQUIPMENT CAR ID | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE AND TEST FAID'S | 33 W MONROE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SMOKE DETECTOR IN HOISTWAY SHALL NOT RECALL ELEVATOR OR BE REMOVED | 33 W MONROE ST | PERMIT | FAILED | View |