Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:11 PM
PIN: 17103170038012
Property Address: 201 E RANDOLPH ST
City - Zip: CHICAGO - 60601
2023 Property Class:
2023 Township: -
2023 Neighborhood:
2023 Tax District:
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 33 Violations
Violation Inspector Comments Address Category Status View
PROV SAFE ACCESS TO CAR GOV SAFE ACCESS TO GOVERNOR ELEVATOR #1-#2 ACCESS DOOR/LADDER WITH SAFETY SWITCH. 201 E RANDOLPH ST PERMIT PASSED View
OPEN TYPE VIOLATION SCHEDULE INSPECTIONS FOR ELEVATOR #3 & #4 CURRENTLY RUNNING TO NEW FLOORS WITHOUT INSPECTIONS AND PRESSURE TEST. 201 E RANDOLPH ST PERMIT PASSED View
OPEN TYPE VIOLATION MAKE NECESSARY REPAIRS ON ELEVATORS #1 & #2 TO PREVENT DRIFTING ONTO BUFFERS ON CAR TOP INSPECTIONS. 18-30-010,13-20-120. 100014982. 201 E RANDOLPH ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA ELEVATOR #4 & #3 NEEDS TO HAVE RETESTOF FAID RECALL 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA RE-SCHEDULE INSPECTION & HAVE FIRE ALARM COMPANY PRESENT TO TEST FAID'S. 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA RE-SCHEDULE INSPECTIONS OF ELEVATORS #1, #2, #3, #4,& MONROE/MICHINGAN KIOSK.PHASE I & PHASE II 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPLACE HOIST ROPES ON ELEVATOR #1N-RAN 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 REMOVE OLD EQUIPMENT FROM MACHINE ROOM ALSO PIPE 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE SIGN ON COUNTERWEIGHT GUARD. 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA ELEVATOR #4 & #3 NEEDS TO HAVE RETEST OF FAID RECALL 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #3 ELEVATOR PHASE I LIGHT AT KEY SWITCH NOT ILLUMINATED 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA RE-SCHEDULE INSPECTIONS OF ELEVATORS #1, #2, #3, & #4.PHASE I & PHASE II 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE CABLE GUARDS ON MACHINE FRONT AND BACK. 201 E RANDOLPH ST PERMIT FAILED View
OPEN TYPE VIOLATION SCHEDULE FIRE SERVICE/SMOKES RECALL TEST. 201 E RANDOLPH ST PERMIT PASSED View
OPEN TYPE VIOLATION PROVIDE ANTI SPIN OUTS FOR COUNTER WEIGHT SHACKLES ELEVATOR #1 & #2. 201 E RANDOLPH ST PERMIT PASSED View
REP/REPL DEF C/S BUTTONS PASS STREET LEVEL & TERRACE LEVEL CAB CAR BUTTONS ALWAYS LIT ELEVATOR 1-2. 201 E RANDOLPH ST PERMIT PASSED View
STOP/REMOVE NUISANCE LOWER LEVEL MEN'S AND WOMEN'S BATHROOM AND HALL AIR HANDLING VENTS - CLOGGED WITH DUST. 201 E RANDOLPH ST COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA LABEL POWER SOURCE LOCATION 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REMOVE THE SMOKES FROM THE TOP OF THE HOISTWAY #3C 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REMOVE THE PROTRUDING SCREWS FROM THE TOP OF THE HOISTWAY #3C 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 FIRE TEST 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 REPAIR INCAR STOP SWITCHE'S 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 RELOCATE PIT SWITCH , GFI OUTLET , LIGHT SWITCH , ADD ADDITIONAL LIGHT'S IN PIT 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 INSTALL HOISTWAY FASCIA 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 PHONE MONITORING 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 FLOOR NUMBER WITH BRAILLE 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 CODE DATA TAG ON CONTROLLER 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SYNCHRONIZED JACK 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA #4 INSTALL PROPER PIT LADDER 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA MOVE PIT LADDER OUT AS MUCH AS POSSIBLE.CAR#2 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA CAR#2- LABEL TOE GUARD AND CAR TOP. 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA TEST FAIDS 201 E RANDOLPH ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA ELEVATOR #3 ALTERNATE FLOOR FIRE SERVICE FLOOR HAS NO EGRESS DANGEROUS & HAZARDOUS 201 E RANDOLPH ST PERMIT FAILED View