The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | NORTH WALL-WASHED OUT MORTAR | 3600 N FREMONT ST | PERIODIC | FAILED | View |
CHIMNEY | NORTH CHIMNEY-WASHED OUT MORTAR | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | INNER REAR WOOD PORCH-LADDER TYPE GUARD RAILS | 3600 N FREMONT ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST-ROTTED WINDOW FRAMES | 3600 N FREMONT ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR-UNABLE TO DETERMINE INTERIOR BUILDING CONDITIONS, STAIRWAYS OR DETECTORS | 3600 N FREMONT ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | SOUTH GAS METER ROOM WITH ACCUMULATION OR DIRT, CARDBOARD BOXES & OTHER DEBRIS | 3600 N FREMONT ST | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | DUE TO THE MANY DEFECTS/DEFICIENT CONDITIONS ON PORCH SYSTEMS, A PERMIT TO REPLACE/REPAIR IS REQUIRED. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALL-WASHED OUT MORTAR | 3600 N FREMONT ST | PERIODIC | FAILED | View |
CHIMNEY | NORTH CHIMNEY-WASHED OUT MORTAR | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | INNER REAR WOOD PORCH-LADDER TYPE GUARD RAILS | 3600 N FREMONT ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST-ROTTED WINDOW FRAMES | 3600 N FREMONT ST | PERIODIC | FAILED | View |
1/2HR FLR OVER BSMT,3+DU,PRE57 | LAUNDRY RM. PLASTER CEILING WITH VARIOUS HOLES | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH EXTERIOR STAIR SYSTEMHAS BEEN SELECTIVELY REPLACED OF VARIOUS COMPONENTS:1. 4X6 BEAMS AT 8'5" IN SPAN, OVER SPANNED, MISSING TIE STRAPS AT WALL & COLUMN, UNSEALED WALL PENETRATIONS; 2. STRINGERS NOT BOLTED TO WALL, POSTS OR COLUMNS, STAIR TREADS ARE CURLING OR CRACKED DUE TO DRY ROTTING; 3. GUARD RAILS UNDER 36" IN HEIGHT, 2ND FL. BROKEN TOP RAIL, MISSING PICKETS, DANGEROUS CONDITION; SOUTH SYSTEM APPEARS ORIGINAL:1. WORN STAIR TREADS; 2. HAND RAILS ARE LADDER TYPE PICKETS, GUARD RAILS TOO LOW, 36" IN HEIGHT; 3. JOISTS SPAN AT 11'6"; 4. LANDINGS WITH FLOOR BOARDS BUCKLED & ROTTING; 5. STRINGERS NOT BOLTED TO WALL , POSTS. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
PARAPET | EAST PARAPET WALL SECTIONS - BRICKS WITH METAL FACADE - LOOSE , FALLING , BULGING , BROKEN , SHIFTING , SPALLING BRICKS WITH WASHED OUT MORTAR - DANGEROUS AND HAZARDOUS. SOUTHWEST PARAPET - SPALLING CONCRETE. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND WEST WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
INSECTS | SOUTH AND EAST WINDOWS AT EXTERIOR - WASPS NEST. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | ENTIRE EAST SIDEWALK AND SOUTH AT ENTRYWAY - SIDEWALK CANOPY REQUIRED FOR PROTECTION FROM LOOSE , FALLING BRICKS AND METAL FACADE. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
RAT PROOF OPENINGS | REAR YARD - RAT HOLES. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH WINDOW SILLS - BRICKS AND WOOD BLOCKS STORED. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR FLOOR | NORTH EXTERIOR BASEMENT - HOLES IN CONCRETE FLOOR. SOUTH EXTERIOR BASEMENT FLOOR - BUCKLED AND BROKEN CONCRETE. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH 3 STORY OPEN WOOD PORCH - TREE BRANCHES HAMPERING EGRESS. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | NORTHEAST BASEMENT WINDOW - BOARDED OVER WITH ROTTED PLYWOOD. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
FLAM LIQ TANK FRONTAGE CONSENT | REAR 3 STORY OPEN WOOD PORCHES - STORING LIGHTER FLUID - FIRE HAZARD. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH GLASS BLOCK WINDOW SECTIONS - BROKEN AND CRACKED GLASS SECTIONS. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH |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| 3600 N FREMONT ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR-UNABLE TO DETERMINE INTERIOR BUILDING CONDITIONS, STAIRWAYS OR DETECTORS | 3600 N FREMONT ST | PERIODIC | FAILED | View |
REPAIR ROOF STRUCTURE | NORTH PORCH ROOF - ROTTED BEAMS , SUBFASCIA , AND ROOF SHEATHING. | 3600 N FREMONT ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2010 THROUGH 2013. | 3600 N FREMONT ST | PERIODIC | FAILED | View |