Chicago Building Violations Data: 28 Violations
Violation Inspector Comments Address Category Status View
PROVIDE 3-STORY HIGH BUILDING OF HEAVY TIMBER CONSTRUCTION (TYPE IIIA) OCCUPIED BY CAR WASH AND OFFICES- MISSING AUTOMATIC SPRINKLER SYSTEM, SEC 9(15-16-030) 356 W SUPERIOR ST PERIODIC FAILED View
SELF-CLOSE CLASS B FIRE DOOR 1ST FLOOR HOT WATER HEATER ENCLOSURE MISSING CLOSER 356 W SUPERIOR ST PERIODIC FAILED View
UNINTERRUPTED EXIT AT GRADE REAR EGRESS 1ST FLOOR BLOCKED 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR EXTERIOR WALL REAR OPEN MORTAR JOINTS 356 W SUPERIOR ST PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION, SOUTH-WEST CORNER, 3RD FLOOR WINDOW, ROUND TRANSOM, GLASS PANE MISSING, PIECE OF PLYWOOD INSTALLED INSTEAD. 356 W SUPERIOR ST PERIODIC FAILED View
PARAPET 1)DANGEROUS AND HAZARDOUS. SOUTH-WEST CORNER, PARAPET WALL, BULGING, SHIFTING MASONRY, SPALLING MORTAR, LEANING OVER PUBLIC WAY; 2) WEST ELEVATION, PARAPET WALL, SPALLING MASONRY, WASHED OUT MORTAR. OBTAIN PLANS AND PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR COPING SOUTH-WEST CORNER, COPING, SECTION, MISSING. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
CHIMNEY DANGEROUS AND HAZARDOUS. WEST ELEVATION, CHIMNEY, OUT OF PLUMB, SEPARATING FROM THE BUILDING, GAP FILLED WITH MORTAR, LEANING TO THE WEST, OUTWARDS, OVER NEIGHBORING PROPERTY. OBTAIN PLANS AND PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR LINTELS 1) SOUTH ELEVATION, FIRST FLOOR, MAIN ENTRANCE DOOR AND STOREFRONT, METAL LINTEL, RUSTED, BENT; 2) NORTH ELEVATION, BACK DOOR AND OVERHEAD GARAGE DOOR, METAL LINTELS, RUSTED, BENT, GAPS ABOVE THEM, FILLED WITH MORTAR. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS SECOND FLOOR, COMMERCIAL UNIT, HALLWAY, SMOKE DETECTOR, MISSING. 356 W SUPERIOR ST PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED FIRST, SECOND AND THIRD FLOORS, MULTIPLE LOCATIONS, EXIT SIGNS, NOT ILLUMINATED. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM DANGEROUS AND HAZARDOUS. NORTH ELEVATION, GROUND TO THIRD FLOOR, INTERIOR, WOOD STAIR SYSTEM: 1) NO VISIBLE FOOTINGS, PIERS, UNDER SUPPORTING COLUMNS; 2) COLUMNS SITTING DIRECTLY ON THE SLAB, NOT ATTACHED, TWISTING, SLIDING; 3) GROUND TO 3RD FLOOR, STAIR STRINGERS, OVER NOTCHED, FACE NAILED ONLY, SUPPORTED BY 2X4 INCHES WOOD BLOCK AT GROUND LEVEL; 4) GROUND LEVEL, FIRST FOUR STAIRS, GOING UP, HANDRAILS, MISSING; 5) GROUND TO THIRD FLOOR, STAIR TREADS, OUT OF PLUMB, LEANING INWARDS, RISERS HEIGHT NOT UNIFORMED; 6) THIRD FLOOR, LANDING, JOISTS BENDING IN THE MIDDLE, CUT IN MIDDLE OF THE SPAN, NOT TIED BACK TO THE WALLS, INADEQUATELY SUPPORTED BY 4X6 INCHES BEAM, WHICH SUPPORTED BY 2X4 INCHES WOOD STUDS SITTING DIRECTLY ON PLYWOOD DECKING, SLIDING, TWISTING, FACE NAILED ONLY; 7) NOTICE POSTED. DO NOT USE; 8) OBTAIN PLANS AND PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR EXTERIOR WALL THIRD FLOOR UNIT, EXTERIOR WALLS, EXPOSED MASONRY, SPALLING MASONRY, SPALLING MORTAR, SHIFTING MASONRY. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY NORTH ELEVATION, BACK EGRESS DOOR, ACCUMULATION / STORAGE OF LARGE PLASTIC BARRELS, OBSTRUCTING PATH OF EGRESS. 356 W SUPERIOR ST PERIODIC FAILED View
PARAPET 1)DANGEROUS AND HAZARDOUS. SOUTH-WEST CORNER, PARAPET WALL, BULGING, SHIFTING MASONRY, SPALLING MORTAR, LEANING OVER PUBLIC WAY; 2) WEST ELEVATION, PARAPET WALL, SPALLING MASONRY, WASHED OUT MORTAR. OBTAIN PLANS AND PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR COPING SOUTH-WEST CORNER, COPING, SECTION, MISSING. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
CHIMNEY DANGEROUS AND HAZARDOUS. WEST ELEVATION, CHIMNEY, OUT OF PLUMB, SEPARATING FROM THE BUILDING, GAP FILLED WITH MORTAR, LEANING TO THE WEST, OUTWARDS, OVER NEIGHBORING PROPERTY. OBTAIN PLANS AND PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR LINTELS 1) SOUTH ELEVATION, FIRST FLOOR, MAIN ENTRANCE DOOR AND STOREFRONT, METAL LINTEL, RUSTED, BENT; 2) NORTH ELEVATION, BACK DOOR AND OVERHEAD GARAGE DOOR, METAL LINTELS, RUSTED, BENT, GAPS ABOVE THEM, FILLED WITH MORTAR. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR EXTERIOR WALL THIRD FLOOR UNIT, EXTERIOR WALLS, EXPOSED MASONRY, SPALLING MASONRY, SPALLING MORTAR, SHIFTING MASONRY. OBTAIN PERMIT FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY NORTH ELEVATION, BACK EGRESS DOOR, ACCUMULATION / STORAGE OF LARGE PLASTIC BARRELS, OBSTRUCTING PATH OF EGRESS. 356 W SUPERIOR ST PERIODIC FAILED View
EXPOSED WIRING SOUTH ELEVATION, GROUND TO 3RD FLOOR, INTERIOR STAIRWAY, FIRST FLOOR, LOBBY, ELECTRICAL BOX, EXPOSED WIRING. 356 W SUPERIOR ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS SECOND FLOOR, COMMERCIAL UNIT, HALLWAY, SMOKE DETECTOR, MISSING. 356 W SUPERIOR ST PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED FIRST, SECOND AND THIRD FLOORS, MULTIPLE LOCATIONS, EXIT SIGNS, NOT ILLUMINATED. 356 W SUPERIOR ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME NORTH ELEVATION, GARAGE DOOR - WOOD FRAME SEVERELY ROTTEN. 356 W SUPERIOR ST PERIODIC FAILED View
WORK W/ EXPIRED/REVOKED PERMIT NORTH, REAR INTERIOR STAIR - REPAIRS MADE TO INTERIOR STAIR UNDER VVOIDED PERMIT 100735017. PERMIT VOIDED PER ARCHITECT OF RECORD 11/21/17. REINSTATE PERMIT OR OBTAIN NEW PERMIT TO AUTHORIZE ALTERATIONS TO STAIRWELL. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. 356 W SUPERIOR ST PERIODIC FAILED View
SUBMIT 2 COPY STRUCTURAL RPT 3RD FLOOR NEAR REAR NORTH INTERIOR STAIR - FLOOR VERY WEAK AND ENTIRE 3RD FLOOR UNEVEN AND SAGS - SUBMIT ENGINEERS REPORT ON STABILITY OF 3RD FLOOR STRUCTURE. PLANS AND PERMIT REQUIRED FOR REPAIRS. 356 W SUPERIOR ST PERIODIC FAILED View
EXPOSED WIRING SOUTH ELEVATION, GROUND TO 3RD FLOOR, INTERIOR STAIRWAY, FIRST FLOOR, LOBBY, ELECTRICAL BOX, EXPOSED WIRING. 356 W SUPERIOR ST PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION, 3RD FLOOR - CIRCLE WINDOW BOARDED UP. 356 W SUPERIOR ST PERIODIC FAILED View