Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 12:26 PM
PIN: 17072180520000
Property Address: 510 N WOLCOTT AVE
City - Zip: CHICAGO - 60622
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77120
2023 Tax District: 77162
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 12 Violations
Violation Inspector Comments Address Category Status View
PARAPET PARAPET WALL - LOOSE BRICKS; WASHED OUT MORTAR. 510 N WOLCOTT AVE COMPLAINT PASSED View
CHIMNEY CHIMNEY - DAMAGED CAUSED BY STORM. PERMIT REQUIRED TO REBUILD. 510 N WOLCOTT AVE COMPLAINT PASSED View
REPAIR ROOF ROOF - PORTIONS OF ROOF BLEW ONTO STREETS AND PUBLIC SIDEWALK AS EVIDENCED BY DAMAGE TO VEHICLE PARKED ACROSS THE STREET FROM BUILDING AND DEBRIS (BRICKS, MORTAR) SURROUNDING PROPERTY. ROOF HAS BEEN TARPED AND SECURED TOL PREVENT FUTURE BLOW-OFF. PLANS AND PERMIT REQUIRED TO REPLACE ROOF STRUCTURE. 510 N WOLCOTT AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, APARTMENTS, INTERIOR STAIRWELLS, BASEMENT, ROOF, REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. 510 N WOLCOTT AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT FOR INSTALLATION OF REAR PATIO DOORS AT 1ST, 2ND, 3RD FLOOR 510 N WOLCOTT AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM FOUNDATION STATUS UNKNOWN-2X10 JOISTS ARE UNDERSIZED, SPANNED 15 FEET NO PROPER CONNECTION AT LOOKOUTS COLUMNS STRINGERS TO LANDING AND RAILS TO BUILDING MISSING METAL TIES THRU-OUT RAILS ARE ONLY 38 INCHES HIGH JOISTS TO RIM JOIST ARE ONLY TOE NAILED NO JOIST HANGERS MISSING MIDDLE 4X4 POST FOR ALL RAILS DEFLECTION OF RAIL UPON LOAD NO BOLTS AT ALL CONNECTION SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS TO REAR PORCH 510 N WOLCOTT AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT ELEVATOR STORE STAIR WITH LARGE GAPS 510 N WOLCOTT AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR 2ND FLOOR-OBTAIN PERMIT FOR INSTALLATION OF FIRE PLACE 510 N WOLCOTT AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR 2ND FLOOR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 2ND FLOOR OR RESTORE THE BUILDING TO THE ORIGINAL STATE 510 N WOLCOTT AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID 2ND FLOOR-MISSING CARBON DETECTOR 510 N WOLCOTT AVE COMPLAINT PASSED View
CHIMNEY HEIGHT CHIMNEY - HEIGHT NOT ABOVE 2'-0". 510 N WOLCOTT AVE COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE 1ST AND 2ND FLOOR-MISSING CEILING VIEWING DEVICE AT FRONT DOORS (PEEP HOLES) 510 N WOLCOTT AVE COMPLAINT PASSED View