Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 12:08 AM
PIN: 17162380120000
Property Address: 404 S WELLS ST
City - Zip: CHICAGO - 60607
2023 Property Class: 591
2023 Township: 76 - South Chicago
2023 Neighborhood: 76010
2023 Tax District: 76102
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 48 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION TO VERIFY SMOKE AND FIRE DETECTOR AND LIFE SAFETY 404 S WELLS ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 404 S WELLS ST PERIODIC FAILED View
REPAIR EXTERIOR WALL REPAIR EXTERIOR WALL - WEST ELEVATION WINDOW HEADS BULGING BRICK, SILLS BULGING OUTWARD.WEST ELEVATION WATER HOSE FROM ROOF TO FIFTH FLOOR UNIT.OBTAIN MASONRY PERMIT FOR ALL REPAIRS. 404 S WELLS ST PERIODIC FAILED View
PROVIDE PROVIDE PER SECTION 13-96-420, SUBMIT 100% HANDS-ON CRITICAL EXAM OF WATER TANK AND WATER TANK STRUCTURE. SUBMIT TO DEPARTMENT OF BUILDINGS, ATTN: JOSE APARICIO, 2045 W. WASHINGTON, 60612 404 S WELLS ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY OBSTRUCTION - EAST ELEVATION FIRE ESCAPE DROP DOWN LADDER FALLS ONTO OUTDOOR RESTURANT EATING PATIO DANGEROUS AND HAZARDOUS. (PATIO CANNOT OPERATE UNDER FIRE ESCAPE. 404 S WELLS ST PERIODIC FAILED View
PROVIDE PROVIDE PER SECTION 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870, 100% HANDS-ON CRITICAL EXAM OF FIRE ESCAPE AND WEST ELEVATION METAL VENT AND STEEL SUPPORTS AND ALL EXPOSED METAL. SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE-COMPLIANCE GROUP, 2045 W. WASHINGTON 60612. 404 S WELLS ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR, RESET WEST ELEVATION REAR DOOR FRAME IMCOMPLETE LARGE OPEN JOINT ALONG FRAME JAMB. 404 S WELLS ST PERIODIC FAILED View
TEST G & S ALL ELE FULL LOAD, FULL SPEED. 404 S WELLS ST PERIODIC CLOSED View
OPEN TYPE VIOLATION INSTALL DOOR RESTRICTOR-PASSENGER CAR 404 S WELLS ST PERIODIC CLOSED View
OPEN TYPE VIOLATION PROVIDE SAFE ACCESS TO ELEVATOR MACHINE ROOM-REPAIR OR REPLACE STAIR, PLATFORM & HANDRAIL. (18-30-010 AND 13-20-120) EV007422 404 S WELLS ST PERIODIC CLOSED View
SEND EX. METAL LETTER SUBMIT FOR ENGINEERS REPORT 404 S WELLS ST COMPLAINT PASSED View
REMOVE RUST REMOVE TREADS, RUST AND CORROSION BETWEEN TREADS AND RISERS 404 S WELLS ST COMPLAINT PASSED View
OPEN TYPE VIOLATION 1. INSTALL FIREMEN'S SERVICE SYSTEM ACCORDING TO CITY OF CHICAGO ELEVATOR INSPECTORS. 18-30-010,13-20-120. 404 S WELLS ST PERMIT FAILED View
SEND EX. METAL LETTER SUBMIT ENGINEER REPORT 404 S WELLS ST COMPLAINT CLOSED View
REMOVE RUST RUST AND CORROSION BETWEEN TREADS AND RISERS 404 S WELLS ST COMPLAINT CLOSED View
TUCK POINT RAILINGS TUCK POINT 404 S WELLS ST COMPLAINT CLOSED View
PROTECT METAL MEMBERS SCRAPE AND PAINT 404 S WELLS ST COMPLAINT CLOSED View
SUBMIT 2 COPIES CRITICAL EXAM DID NOT FILE CRITICAL EXAMINATION DUE NOT LATER THAN 12/1/2003 AS OF JANUARY 20, 2010. IF THE BUILDING IS OCCUPIED AND HAZARDOUS CONDITIONS DO NOT EXIST ON THE BUILDING, OWNERS MAY TAKE ADVANTAGE OF THE REDUCED INSPECTION COVERAGE IN AMENDED RULES AND REGULATIONS PUT IN EFFECT OCTOBER 22, 2009 AND MAY FILE ONGOING MAINTENCE AND REPAIR REPORT "SHORT FORMS" EVERY SECOND YEAR AFTER SUBMITTING A CURRENT CRITICAL EXAMINATION. CALL ALLISON SULLIVAN AT 312-743-3522 WITH QUESTIONS. 404 S WELLS ST COMPLAINT PASSED View
POST APPROVED OCCUPANCY CARD OBTAIN AND POST NEW OCCUPANCY CARDS WITH DIAGRAMS FIXED SEATING REMOVED AND BAR HAS BEEN SHORTENED LAYOUT CHANGE RE-SUBMIT 404 S WELLS ST PERIODIC PASSED View
OPEN TYPE VIOLATION 404 S WELLS ST PERIODIC PASSED View
NOTIFY DOB, USE OF VACANT LND INTERIOR OF BUILDING/2ND THRU 6TH FLOORS-VACANT AND SECURED. 404 S WELLS ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY FOR ANNUAL INSPECTION. CALL 312-907-3966 404 S WELLS ST PERIODIC FAILED View
PROTECT METAL MEMBERS PROTECT METAL MEMBERS 404 S WELLS ST COMPLAINT PASSED View
REMOVE RUST REMOVE RUST 404 S WELLS ST COMPLAINT PASSED View
SEND EX. METAL LETTER SUB ENG REPORT 404 S WELLS ST COMPLAINT PASSED View
PLUM WATER TANK PLUM WATER TANK 404 S WELLS ST COMPLAINT PASSED View
EX. MET. FOR WATER TANKS REPORT PREPARED BY LICENSED ARCHITECT OR STRUCTURAL ENGINEER 404 S WELLS ST COMPLAINT PASSED View
ARRANGE FOR RE-INSPECTION GAS FIRED OPEN FLAME DUCT HEATER INSTALLED UPSTREAM OF DX CCOLING COIL,NEED PERMIT FOR ADDITIONAL WORK DONE WITHOUT PERMIT 404 S WELLS ST PERMIT FAILED View
ARRANGE FOR RE-INSPECTION GAS FIRED DUCT HEATERS UPSTREAM OF DX COIL 404 S WELLS ST PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 18-28-106.1 INSPECTION REQUIRED 13-32-270 WARM AIR FURNACES ARRANGE FOR COMPLETE PERMIT INSPECTIONS AND OBTAIN PERMITS FOR WARM AIR HEATING SYSTEMS AND VENTILATION SYSTEMS WHEN WORK IS COMPLETE 404 S WELLS ST COMPLAINT FAILED View
SUBMIT PLANS/GET VENT PERMIT 13-32-010 PERMIT REQUIRED 13-32-020 *SUBMIT PLANS AND OBTAIN VENTILATING SYSTEMS PERMITS 404 S WELLS ST COMPLAINT FAILED View
STOP RECIRCULATING AIR 28(13-176-130) HEATING FOR MECHANICAL SYSTEM *MAINTAIN TEMPERATIVE IN BUILDING WHEN 33 1/3 PERCENT OF CODE REQUIRED AIR SUPPLIED-TEMPER OUT SIDE AIR CODE MINIMUM ONLY (THIS IS OUTSIDE AIR BROUGH INTO FURNACE) 404 S WELLS ST COMPLAINT FAILED View
REMOVE REMOVE COOLING EQUIPMENT FROM FURNACE AND INSTALL DOWN STREAM OF FURNACE TO PREVENT CONDENSATION WITHIN HEATING ELEMENTS 404 S WELLS ST COMPLAINT FAILED View
OPEN TYPE VIOLATION (VT 6011) 18-28-506 COMMERCIAL KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT SHALL COMPLY WITH REQUIREMENTS SECTION 18-28-506 AND SHALL BE DESIGNED FOR TYPE OF COOKING APPLIANCE AND HOOD SERVE. 1) ALL BLACK IRON CONNECTIONS SHALL BE WELDED LIQUID TIGHT. 2) CLEARANCE FOR GREASE DUCT IS 18 INCHES FROM COMBUSTIBLE CONSTRUCTION OR FIRE WRAPPED WITH 2 LAYS OF INSULATION. 404 S WELLS ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PERMIT FOR RENOVATION WORK IN PROGRESS ON 4-13-16. SEE NEW CONCRETE FLOOR, NEW HVAC SYSTEM AND NEW ELECTRICAL. 404 S WELLS ST PERIODIC PASSED View
PROVIDE CLASS A FIRE DOOR REPAIR FIRE SHUTTER AT REAR. THE FUSIBLE LINK MECHANISM IS BROKEN. UPON COMPLETION OF REPAIR SUBMIT DOCUMENTATION THAT SHUTTER IS OPERABLE. 404 S WELLS ST PERIODIC PASSED View
ARRANGE FOR REINSPECTION REGAR CONTACT DEPARTMENT OF BUIDINGS AT 312-743-0407 FOR REINSPECTION. THE PUBLIC PLACE OF ASSEMBLY LICENSE IS NOT APPROVED UNTIL VIOLATIONS ARE CORRECTED. 404 S WELLS ST PERIODIC PASSED View
ARRANGE PREMISE INSPECTION UNABLE TO GAIN INTERIOR ACCESS FOR 2022 ANNUAL INSPECTION. 404 S WELLS ST PERIODIC FAILED View
HEATING PLANT ENCLOSURE ENCLOSE FURNACES AT NORTH MEZZANINE. ENCLOSURE TO INCLUDE SELF CLOSING, SELF LATCHING CLASS B FIRE DOOR AND FRAME. WORK REQUIRES A PERMIT. 404 S WELLS ST PERIODIC PASSED View
REPAIR EXTERIOR WALL WEST ELEVATION SEVERE STONE SILLS CRACKED, LOOSE PIECES.STONE AND BRICK SEVERE DAMAGED CAUSED BY RUST AT ALL FIRE ESCAPE CONECTION POINTS.MASONRY PERMIT FOR ALL REPAIRS. 404 S WELLS ST PERIODIC FAILED View
PROVIDE PER SECTION CODES 13-96-820, 13-96-830, 13-96-850, 13-96-870, SUBMIT EXPOSED METAL FIRE ESCAPES 100% HANDS-ON CRITICAL EXAM, SUBMIT TO DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLINACE GROUP, 2045 W. WASHINGTON, 60612 404 S WELLS ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. 404 S WELLS ST PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER/MANAGEMENT ID SIGN POSTED 404 S WELLS ST PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA EMERGENCY PHONE DOESN'T WORK. PASSENGER ELEVATOR. 404 S WELLS ST COMPLAINT CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA INSTALL SMOKE DETECTORS AT 6TH. FLOOR FOR ELEVATOR FIRE RECALL. 404 S WELLS ST COMPLAINT CLOSED View
MAINTAIN OR REPAIR ELECT ELEVA FINALIZE OPEN MODERNIZATION PERMIT #100093311. 404 S WELLS ST COMPLAINT CLOSED View
OPEN TYPE VIOLATION PROGRAM EMERGENCY TELEPHONE TO A 24 HR ANSWERING SERVICE-PASSENGER CAR 404 S WELLS ST PERIODIC CLOSED View
WATER TANK BANDS WATER TANK BANDS 404 S WELLS ST COMPLAINT PASSED View