Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 6:30 PM
PIN: 17203110210000
Property Address: 1836 S BLUE ISLAND AVE
City - Zip: CHICAGO - 60608
2023 Property Class: 212
2023 Township: 77 - West Chicago
2023 Neighborhood: 77141
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL WEST ELEVATION,2ND AND 3RD FLOORS,WASHED OUT MORTAR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
PARAPET EAST ELEVATION,PARAPET,WASHED OUT MORTAR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS FRONT STAIRWAY,3DR FLOOR,MISSING SMOKE DETECTOR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION,2ND AND 3RD FLOORS,WASHED OUT MORTAR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
PARAPET EAST ELEVATION,PARAPET,WASHED OUT MORTAR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS FRONT STAIRWAY,3DR FLOOR,MISSING SMOKE DETECTOR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
FLAKY INTERIOR PAINT EAST ELEVATION EXTERIOR BRICKS,LINTELS ANS WOOD TRIM HAS LOOSE AND FLAKY PAINT. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE/ENTRY AT TIME OF INSPECTION TO VERIFY OCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2012 ANNUAL INSPECTION. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS FRONT STAIRWAY,3DR FLOOR,MISSING SMOKE DETECTOR. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
REPAIR ROOF EAST ELEVATION (2X20FT)ROOF HAS SPALLING AND BROKEN CONCRETE. 1836 S BLUE ISLAND AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR INTERIOR BUILDOUT OF THE 1ST FLOOR COMMERCIAL SPACE. 1836 S BLUE ISLAND AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# NO OWNERS ID POSTED NOT OWNER OCCUPIED 1836 S BLUE ISLAND AVE PERIODIC PASSED View
INT WALL/CEILING CHIP PLASTER RESTAURANT CEILING TILES WATER DAMAGED, MISSING METAL CEILING ABOVE DROP CEILING FALLING APART AND FALLING DOWN OVER RESTAURANT SITTING AREA DANGEROUS 1836 S BLUE ISLAND AVE PERIODIC PASSED View
STOP LEAKING WATER WATER LEAKING FROM 2ND FLOOR ONTO RESTAURANT 1836 S BLUE ISLAND AVE PERIODIC PASSED View
NO KEY TO USE EXIT DOOR RESTAURANT FRONT DOOR DOUBLE KEYED 1836 S BLUE ISLAND AVE PERIODIC PASSED View
OBSTRUCTIONS IN EXIT WAY EGRESS AT REAR FIRESCAPE BLOCKED BY BYCICLES, BOXES AND MUCH JUNK 1836 S BLUE ISLAND AVE PERIODIC PASSED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN PANE RESTAURANT WINDOW BY COOKING AREA, GLASS BLOCK UNITS OVER FRONT BUILDING ENTRY DOOR NOT SUPPORTED. 3RD FLOOR HALL 1836 S BLUE ISLAND AVE PERIODIC PASSED View
REPAIR EXTERIOR WALL BRICKS OVER AND AROUND BUILDING ENTRY WAY ARE LOOSE, CEMENT COATING 1836 S BLUE ISLAND AVE PERIODIC PASSED View
INSTALL SMOKE DETECTORS BASEMENT NO SMOKE DETECTOR 3 FRONT, STAIRS 1836 S BLUE ISLAND AVE PERIODIC PASSED View
CARB MONOX DETECT IN RESID BASEMENT NO CARBON MONOXIDE DETECTOR. 3- FRONT 1836 S BLUE ISLAND AVE PERIODIC PASSED View
CONNECT GAS APPLIANCE TO VENT PLUE PIPE IN BASEMENT FOR WATER HEATERS NOT CONNECTED AND UP AND DOWN 1836 S BLUE ISLAND AVE PERIODIC PASSED View
STRUCTURAL MEMBER, PIER BLOCK BASEMENT CEILING JOIST MANY ROTTED MEMBERS AND LEANING WITH NO BLOCKING, MANY 6X6 TEMPORARY POST INSTALLED WITH TEMPORARY BEAMS WITH SOME SUPPORT PAST 4X6 WITH SOME ROTTING, SUPPORT BEAMS FROM FRONT TO BACK VERY UNEVEN. THESE JOIST SUPPORT AND UP STAIRS RESTAURANT AND KITCHEN DANGEROUS 1836 S BLUE ISLAND AVE PERIODIC PASSED View
SUBMIT 2 COPY STRUCTURAL RPT PROVIDE A LETTER FROM A STRUCTURAL ENGINEER ON THE INTEGRITY AND SAFE OCCUPANCY OF 1ST FLOOR RESTUARANT DUE TO DAMAGE FLOOR JOIST AND SUBMIT TO THE CITY OF CHICAGO, CARRIE WAGNER AT 120 N. RACINE AVENUE BY 08-16-06. 1836 S BLUE ISLAND AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS TO MAKE ANY AND ALL REPAIRS AS CALLED FOR IN ENGINEERS REPORT TO BRING BUILDING UP TO THE CODE OF THE CITY OF CHICAGO. 1836 S BLUE ISLAND AVE PERIODIC PASSED View
REPAIR DOWNSPOUT DOWNSPOUT AT REAR NOT CONNECTED TO SEWER 1836 S BLUE ISLAND AVE PERIODIC PASSED View
INSUFFICIENT MEANS OF EGRESS 3RD FLOOR FRONT HAS ONLY ONE MEANS OF EGRESS. 1836 S BLUE ISLAND AVE PERIODIC PASSED View
REPAIR EXTERIOR DOOR 3RD FLOOR REAR APARTMENT FRONT ENTRY DOOR SWINGS OUTWARD. 1836 S BLUE ISLAND AVE PERIODIC PASSED View
INSTALL DEAD BOLT LOCK 2ND FLOOR FRONT APARTMENT MISSING DEADBOLT 1836 S BLUE ISLAND AVE PERIODIC PASSED View
DWELLING CLEAN AND SANITARY INTERIOR STAIRS AND FLOOR LANDINGS VERY DIRTY. 1836 S BLUE ISLAND AVE PERIODIC PASSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS 1836 S BLUE ISLAND AVE PERIODIC PASSED View
BLANK-TEXT MUST CITE CODE SECT STOP ALL WORK UNTIL A PERMIT IS OBTAINED,SEC.13-12-080,13-32-035. 1836 S BLUE ISLAND AVE COMPLAINT PASSED View