The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | SUBMIT DOCUMENTATION FOR SEPARATIONS, ALTERATIONS, OF CHANGE OF USE, CONSTRUCTION OF SEATING PLATFORMS FIRST FLOOR MEZZANINE APARTMENT, FIRST FLOOR TO BASEMENT OPENING APPROXIMATELY 10 'X 6', RATINGS AT STAIRWELL DOORS, REPAIRS OF PORCH, COLUMNS AT BASEMENT SUPPORTING 1ST FLR JOIST. | 1820 S HALSTED ST | PERIODIC | CLOSED | View |
OPEN TYPE VIOLATION | FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 08/03/10. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPARTMENT OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION OF PREMISES PLEASE CALL (312) 743 - 3538. | 1820 S HALSTED ST | PERIODIC | CLOSED | View |
REPLACE D&H PORCH | TWO STORRY REAR WOOD PORCH,COLUMNS SITTING ON CEMENT BLOCK THAT ARE SITTING ON A RETAINING WALL THAT IS BOWING INWARD UNTO BSMNT WELL-COLUMNS ARE ROTTED AT GRADE AND BY FIRE CUTS-BEAMS ARE FIRE CUT INTO COLUMNS-PORCH DECKING IS 3/4 PLYWOOD-STAIRS ARE VERY STEEP-BROKEN AND LOOSE STEPS-STRINGERS NOT PROPERLY CONNECT AND LEANING POSTED DANGEROUS PLANS AND PERMIT FOR REPLACEMENT STAIRS ARE SHARRED BY ADJACENT BUILDING | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | 2 REAR DOUNSPOUTS DRAIN UNTO REAR YARD | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR BASEMENT EXIT DOOR IS SCREWED SHUT | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR BASEMENT EXIT STAIRS TO GRADE ARE MISSING | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | IN BASEMENT USING TEMPORARY SHORING TO SUPPORT 1ST FLOOR JOIST THAT ARE ROTTED AT ENDS | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | EXIT LIGHT OUT 1ST FLOOR REAR | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR 2ND FLOOR HALLWAY | 1820 S HALSTED ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT TO MAKE REPAIRS ON THE FIRST FLOOR JOIST,LARGE OPENNING ON THE FLOOR AT FIRST FLOOR LEVEL,INSTALLING A MAZZANINE LEVEL AT 1ST FLOOR,TO INSTALL EXIT STAIRS FROM REAR BASEMENT WELL TO GRADE,TO REPLACE REAR PORCH | 1820 S HALSTED ST | COMPLAINT | FAILED | View |