Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SEND EX. METAL LETTER | EXPOSED METAL LETTER (SMOKE STACK) | 445 W WELLINGTON AVE | COMPLAINT | CLOSED | View |
PROTECT METAL MEMBERS | SCRAPE AND PAINT | 445 W WELLINGTON AVE | COMPLAINT | CLOSED | View |
REPAIR EX. MET. | ENGINEER REPORT | 445 W WELLINGTON AVE | COMPLAINT | CLOSED | View |
TEST G & S ALL ELE | PERFORM 5YR FULL LOAD SAFETY TEST-BOTH ELEVATORS | 445 W WELLINGTON AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | DO A COMPLETE FIRE SERVICE RECALL TEST PHASE I & II WITH SMOKE DETECTOR TEST AT THE END OF THE MODERNIZATION | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
SELF-CLOSE DOOR >4 STORY RES. | UNIT 15G - DOOR DOES NOT LATCH - ADJUCT CLOSER.UNIT 15F - DOOR DOES NOT LATCH.UNIT 10D - DOOR DOES NOT LATCH.UNIT 7A - DOOR DOES NOT LATCH.UNIT 6H - DOOR DOES NOT LATCH. - RUBS | 445 W WELLINGTON AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | ALL FIRE EXTINGUISHERS EXPIRED JUNE 2014. | 445 W WELLINGTON AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | UNIT 13D MISSING SMOKE DETECTOR. | 445 W WELLINGTON AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | EITHER PROVIDE EMERGENCY POWER FOR ELEVATORS OR REMOVE ALL INDICATORS OF EMERGENCY POWER OPERATION IN HALL STATIONS AND ELEVATOR CONTROL PANEL | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE FIREMAN KEY BOX IN ELEVATOR CONTROL PANEL | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE WATER IN PIT PROVIDE SUMP PUMP | 445 W WELLINGTON AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL ALL HOISTWAY COVERS AS NEEDED | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE FINISH CAB CEILING | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE DOOR CLOSER ON MACHINE ROOM DOOR | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PATCH ALL HOLES IN HOIST WAY TO MACHINE ROOM AND FLOOR'S | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | HUILD 2HR RATED MACHINE ROOM WTIH SELF CLOSING & SELF LOCKING DOOR | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL NEW HALL BUTTONS 2 MASTER PANEL 3 TOP ACCESSS KEY SWTICH | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY ILLUMINATE MACHINE ROOM & ELEVATOR'S BOTH CARS | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL GFI RECEPTACLE'S IN MACHINE ROOM & PITS | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CLEAN PITS & REMOVE WATERS SEAL FLOOR FROM WATER, CLEAN DRAIN OR ADD SUMP PUMP | 445 W WELLINGTON AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD STEP TO MACHINE DECK & 2 LADDER IN ELEVATOR PITS | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY IDENTIFY ALL ELEVATOR EQUIPMETN 2 STENCIL ALL CAR TOPS INIDE HOISTWAY DOORS 3 ALL ELEVATOR DOOR JAMB WITH THE PROPER CAR IDENTIFICATION NUMBERS | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL LIGHTS MUST HAVE COVERS, OR BULB PROTECTOR'S | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CHANGE ALL ROLLER GUIDE'S THAT ARE BACK | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MAINTENNACE CONTROL PROGRAM, 2) MOTHLY FIRE SERVICE LOG BOOK 3) CODE DAT TAGS AT THE END OF MODERNIZATION | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM A COMPLETE FIRE SERVICE TEST & SMOKE DETECTOR TEST AT THE END OF MODERNIZATION | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MUST INTALL SMOKE DETECTOR ON EVERY FLOOR & MACHINE ROOM NO HEAT DETECTOR NEEDED | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD LIGHT TO STAIR CASE GOING TO MACHINE ROOM | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD FAN GUARD TO BOTH ELEVATOR'S | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL MACHINE ROOM DOORS | 445 W WELLINGTON AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPLACE BUFFER CAR #1 OR SHOW PROOF OF STRIKE FROCE (2) REPLACE BUFFER STAND CAR #2. | 445 W WELLINGTON AVE | PERMIT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER SECTION CODE 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870 100% HANDS-ON CRITICAL EXAM INSPECTION FOR RUSTED SMOKE STACK.COMPLETE ALL REPAIRS AS REQUIRED PER PROFESSIONAL EXPOSED METAL REPORT.OBTAIN PERMIT FOR ALL REPAIRS.SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLIANCE GROUP, 121 N. LASALLE 9TH FLOOR, 60601 | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER SECTION CODE 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870 100% HANDS-ON CRITICAL EXAM INSPECTION FOR RUSTED SMOKE STACK.COMPLETE ALL REPAIRS AS REQUIRED PER PROFESSIONAL EXPOSED METAL REPORT.OBTAIN PERMIT FOR ALL REPAIRS.SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLIANCE GROUP, 121 N. LASALLE 9TH FLOOR, 60601 | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
OWNER OR LICENSED CONTRACTOR | 445 W WELLINGTON AVE | PERIODIC | PASSED | View | |
INSTALL BOILER RELIEF VALVE | BRYAN BOILER #1 NB# 48686. | 445 W WELLINGTON AVE | PERIODIC | PASSED | View |
LEAKING RETURN VALVES | BRYAN BOILER #1 NB# 48686. | 445 W WELLINGTON AVE | PERIODIC | PASSED | View |
SCREEN OUTER DOORS, WINDOWS | SOUTH ELEVATION - TORN WINDOW SCREENS. | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WEST DRIVEWAY CEILING HAS HOLES. | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /MOST APARTMENTS - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. | 445 W WELLINGTON AVE | PERIODIC | FAILED | View |
1HR ENCL FLR TO FLR SHAFT/DUCT | 6TH FLOOR ELECTRICAL CLOSET - HOLE IN SOUTH WALL INTO PLUMBING SHAFT. MISSING COMPLETE FIRE RATED ENCLOSURE. | 445 W WELLINGTON AVE | COMPLAINT | FAILED | View |