Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:52 PM
PIN: 17201010120000
Property Address: 1401 W ROOSEVELT RD
City - Zip: CHICAGO - 60608
2023 Property Class: 397
2023 Township: 77 - West Chicago
2023 Neighborhood: 77141
2023 Tax District: 77107
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 23 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS SR#08-00071424 MISSING SMOKE DETECTORS AT TOP OF STAIRS. 1401 W ROOSEVELT RD PERIODIC FAILED View
INSTALL SMOKE DETECTORS SR#08-00071424 MISSING SMOKE DETECTORS AT TOP OF STAIRS. 1401 W ROOSEVELT RD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING/NO ENTRY TO MOST UNITS,UNVERIFIER DETECTORS,(OCCUPANCY,AND CONDITIONS). 1401 W ROOSEVELT RD COMPLAINT PASSED View
INSTALL SMOKE DETECTORS SR#08-01212087 BOILER ROOM: MISSING SMOKE DETECTOR 1401 W ROOSEVELT RD COMPLAINT FAILED View
FILE BLDG REGISTRATION BLDG. NOT REGISTERED FROM 1990 - 2010 1401 W ROOSEVELT RD PERIODIC FAILED View
FILE BLDG REGISTRATION BLDG. NOT REGISTERED FROM 1990 - 2010 1401 W ROOSEVELT RD PERIODIC PASSED View
OWNER OR LICENSED CONTRACTOR 1401 W ROOSEVELT RD PERIODIC PASSED View
INSTALL BOILER RELIEF VALVE ON BURNHAM CAST IRON BOILER #1. 1401 W ROOSEVELT RD PERIODIC PASSED View
INSTALL BOILER RELIEF VALVE ON BURNHAM CAST IRON BOILER #2. 1401 W ROOSEVELT RD PERIODIC PASSED View
REPLACE RELIEF VALVE ON LOCHINVAR HOT WATER TANK WITH VALVE RATED AT 1,000,000 BTU/HR RELIEVING CAPACITY OR HIGHER WITH A SET PRESSURE NO HIGHER THAN 125 PSI. 1401 W ROOSEVELT RD PERIODIC PASSED View
REMOVE RELIEV ON LOCHINVAR HOT WATER TANK THAT HAS A SET PRESSURE OF 150 PSI. MAXIMUM ALLOWABLE WORKING PRESSURE OF TANK IS ONLY 125 PSI. 1401 W ROOSEVELT RD PERIODIC PASSED View
REMOVE PIPE UNION CONNECTED TO LOCHINVAR HOT WATER TANK RELIEF OUTLET. 1401 W ROOSEVELT RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA PERFORM CAT1 TEST AND PROVIDE DOCUMENTATION 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROVIDE IN CASE OF FIRE SIGNS TO ALL LANDINGS 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CAT1 AND PROVIDE DOCUMENTATION 1401 W ROOSEVELT RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE CURRENT MAINTENANCE RECORDS LAST LOG WAS 2013 1401 W ROOSEVELT RD PERIODIC PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - MANAGEMENT NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF BEDBUGS IN SENIOR BUILDING. 1401 W ROOSEVELT RD COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE STORAGE ITEMS FROM MACHINE ROOM. 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA DOOR OPEN BUTTON DOESN'T WORK. ELEVATOR #2 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CODE DATA PLATE REQUIRED ON CONTROLLER. BOTH ELEVATORS. 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CAT. 1 TEST OVERDUE. BOTH ELEVATORS 1401 W ROOSEVELT RD PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA REPAIR PHASE 1 OPERATION: ELEVATORS WILL NOT RETURN TO NORMAL OPERATION AFTER PHASE 1 IS TURNED OFF. 1401 W ROOSEVELT RD PERIODIC PASSED View
MAINTAIN OR REPAIR ELECT ELEVA CAT. 1 TEST IS OVERDUE. BOTH ELEVATORS 1401 W ROOSEVELT RD PERIODIC PASSED View