Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | SOUTH ELEVATION 2 STORY BACK PORCH HAS 2X8 JOIST SPANNING OVER 12FT,GUARDRAILS UNDER 42" HIGH;MISSING 4X4 POST EVERY 4FT AND RAILINGS ARE TOENAILED TO COLUMNS,SPLICES ARE 12" LONG WITH 3/8 BOLTS,FIRECUTS ARE PULLING AWAY AT BEAM TO COLUMN CONNECTIONS AND FOUNDATIONS ARE UNKNOWN SUBMIT PLANS AND OBTAIN PERMIT BEFORE REPAIRING OR REPLACING PORCH. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION WINDOW SILLS HAVE WASHED OUT MORTER JOINTS. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION SECTION OF STONE MISSING AT TOP OF WALL. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND FLR HALLWAY SKYLITE HAS SHATTERED PANES OF GLASS. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR HALLWAY HAS MISSING SMOKE DETECTORS. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED | 2ND FLOOR FORCED AIR FURNACE LOCATED IN BATHROOM NO PERMIT ON FILE. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | 2ND FLOOR BATHROOM AND KITCHEN SINK NO HOT WATER (60DEGREES). | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | PROVIDE HOT WATER TO ALL FIXTURES | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 3057 W JACKSON BLVD | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 3057 W JACKSON BLVD | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH.UNABLE TO VERIFY COMPLIANCE ON PREVIOUS VIOLATIONS. (SEE INSPECTION #10311179 OF 7/25/11). | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED | OBTAIN PERMIT FOR FENCE OVER 5FT. HIGH. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLAN AND PERMIT FOR REAR PORCH. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST AND 2ND FLOOR ENTRY DOORS MISSING PEEPHOLES. | 3057 W JACKSON BLVD | COMPLAINT | FAILED | View |