Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:01 PM
PIN: 13354220020000
Property Address: 1651 N SPAULDING AVE
City - Zip: CHICAGO - 60647
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71180
2023 Tax District: 71187
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS APARTMENT 1 MISSING SMOKE DETECTOR 1651 N SPAULDING AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID APARTMENT 1 MISSING CARBON MONOXIDE 1651 N SPAULDING AVE COMPLAINT PASSED View
UNAPPROVED HEATING DEVICE APARTMENT 1 USING STOVE FOR HEAT 1651 N SPAULDING AVE COMPLAINT PASSED View
SAFE WORKING CONDITIONS APARTMENT 1 BROKEN FURNACE 1651 N SPAULDING AVE COMPLAINT PASSED View
REPAIR STOOP SR#06-00898528 - FRONT STOOP BROKEN & SCABBED STRINGER ROTTED TREADS 1651 N SPAULDING AVE COMPLAINT PASSED View
REPLACE D&H PORCH EAST PORCH UNDERSIZED 6"X6" BEAMS & 2'X 8" JOISTS FOR 6'X6" & 12' SPAN & SCABBED BEAMS GUARDRAILS LESS THAN 42" PORCH IN DANGEROUS & HAZARDOUS CONDITION. PROVIDE PLAN & PERMIT TO REPAIR OR REPLACE. 1651 N SPAULDING AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR BASEMENT HAS BEEN ALTERED FROM ORIGINAL STORAGE INTO A DWELLING UNIT PROVIDE PERMIT TO DECONVERT 1651 N SPAULDING AVE COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT FRONT @ EGRESS TREADS 4" WIDE 1651 N SPAULDING AVE COMPLAINT PASSED View
STAIRWELL ENCLOSURE - BASEMENT BASEMENT FRONT EGRESS ENCLOSURE IS 1/2 HOUR 1651 N SPAULDING AVE COMPLAINT PASSED View
NATURAL LIGHT NEEDED BASEMENT INADEQUETE NATURAL LIGHT 1651 N SPAULDING AVE COMPLAINT PASSED View
BLOWER SYSTEM DIRECTLY OUTSIDE BASEMENT WINDOWS GLASS BLOCK 1651 N SPAULDING AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE WEST ENTRY DOOR TO BASEMENT LOOSE HINGERS WEST 1ST FLOOR DEFECTIVE DOOR KNOB. NORTH DOWNSPOUT MISSING SECTION ALL GUTTER 1651 N SPAULDING AVE COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY EAST SERVICE WALK UNEVEN & MISSING SECTION. 1651 N SPAULDING AVE COMPLAINT PASSED View
REPAIR / REBUILD SHED GARAGE MISSING OVERHEAD DOORS ROOF EXPOSED WOOD - WALL OUT OF PLUMB 1651 N SPAULDING AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS 1651 N SPAULDING AVE PERMIT PASSED View
SEPARATION OF DWELLING ADEQUAT BASEMENT SEPARATION IS 1/2 HOUR 1651 N SPAULDING AVE COMPLAINT PASSED View
REPAIR OR REPLACE NORTH DOWNSPOUT MISSING SECTION 18-29-1101.2.1 1651 N SPAULDING AVE COMPLAINT PASSED View
HEAT UNIT ADEQUATELY APARTMENT 1 59 DEGREES AT 4:45 PM NO HEAT PROVIDED 1651 N SPAULDING AVE COMPLAINT PASSED View