Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 2:21 PM
PIN: 25223040220000
Property Address: 157 E KENSINGTON AVE
City - Zip: CHICAGO - 60628
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70210
2023 Tax District: 70002
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 12 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR FRONT 2-STORY OPEN WOOD STAIR -(1) ALL WOOD EXTREMELY ROTTEN, WARPED, SPLIT AND/OR BROKEN(2) NAILS ARE RUSTED AND PULLING AT JOINTS EXPOSING LARGE GAPS AND WEAK CONNECTIONS(3) ENTIRE STAIR STRUCTURE - SUBSTANTIALLY SWAY FROM SIDE-TO-SIDE WHEN TRAVELING UP AND DOWN(4) STAIR HANDRAILS AND LANDING GUARDRAILS ARE WEAK AND MOVES WHEN GRABBED(5) STAIR STRINGERS AND DECK JOIST ARE ONLY FACE NAILED OR TOE NAILED(6) COLUMNS BEAR DIRECTLY ON THE CONCRETE SLAB WITH NO FOUNDATIONS(7) DRAWINGS ARE REQUIRED TO OBTAIN THE PERMIT 157 E KENSINGTON AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM WEST INTERIOR STAIRWAY -(1) FROM FIRST FLOOR TO INTERMEDIATE LANDING - ONLY 20 INCHES WIDE(2) INTERMEDIATE LANDING TO 2ND FLOOR - ONLY 28 INCHES WIDE(3) NORTH HANDRAIL - MISSING AND CREATING A FALL HAZARD(4) WINDERS - TAPERED TREADS ARE ONLY A MAXIMUM OF 9 INCHES DEEP(5) DRAWINGS ARE REQUIRED TO OBTAIN THE PERMIT 157 E KENSINGTON AVE COMPLAINT FAILED View
SEPARATION OF DWELLING WEST INTERIOR STAIRWAY WALLS SHARED WITH APARTMENTS - FIRE RATED CONSTRUCTION MISSING WITH AREAS OF EXPOSED WOOD STUDS 157 E KENSINGTON AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT, WEST INTERIOR STAIRWAY 3RD FLOOR, APARTMENTS 2F AND 2R - SMOKE DETECTORS MISSING (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, 14B-9-915.4.4, AND 14R-11-1104) 157 E KENSINGTON AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG APARTMENTS 2F AND 2R - THE KITCHEN SINK AND BATHROOM LAVATORY HOT WATER TEMPERATURES WERE ONLY 93DEG.F AFTER RAPIDLY RUNNING FOR AROUND 5MINUTES (14X-9-905.2, 14X-9-905.2.1 AND 14X-9-905.5) 157 E KENSINGTON AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS APARTMENT 2R - WITH AN OUTSIDE TEMPERATURE OF 52DEG.F THE VERICAL GAS WALL SPACE HEATER WAS BROKEN WITH MISSING PARTS VISIBLE (14X-3-305.1, 14X-8-804.1, 14X-8-804.4 AND 14X-8-804.5) 157 E KENSINGTON AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM APARTMENTS 2F AND 2R BATHROOM LAVATORIES - STANDING WATER IN FACE BOWLS DID NOT DRAIN DURING INSPECTION 157 E KENSINGTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 2-STORY PARTIALLY OPEN WOOD PORCH -(1) ALL WOOD ROTTEN, WARPED, SPLIT AND/OR BROKEN(2) NAILS ARE RUSTED AND PULLING AT JOINTS EXPOSING LARGE GAPS AND WEAK CONNECTIONS(3) STAIR HANDRAILS AND LANDING GUARDRAILS ARE WEAK WITH PICKETS MISSING(4) STAIR STRINGERS AND DECK JOIST ARE ONLY FACE NAILED OR TOE NAILED(5) PARTIALLY ENCLOSED WITH 2ND FLOOR LIVING SPACES BUILT WITH NO DRAWINGS OR PERMITS ON FILE(6) DRAWINGS ARE REQUIRED TO OBTAIN THE PERMIT 157 E KENSINGTON AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT, APARTMENTS 2F AND 2R - CARBON MONOXIDE DETECTORS MISSING (14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2 , AND 14R-11-1105) 157 E KENSINGTON AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY WHILE 52DEG.F OUTSIDE AT 10:36AM IN APARTMENT 2R AND WITH THE ONLY PRIMARY HEATER BROKEN - THE AIR TEMPERATURE IN THE THE LIVING ROOM WAS 66DEG.F AND THE BEDROOM WAS 61DEG.F (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) 157 E KENSINGTON AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE VARIOUS WINDOWS THROUGHOUT - SASHES INSIDE OF NON-PLUMB FRAMES AND NON-SQUARE OPENINGS DEFORMING THE WINDOWS SO THEY CANNOT OPEN - CRACKED/BROKEN/MISSING GLASS PANES AND SASHES WITH GAPS ALLOW SUBSTANTIAL AIR SEEPAGE AND INSECTS INSIDE (14X-3-303.13 AND 14X-12-1202.4.3.3) 157 E KENSINGTON AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED SINGLE FAMILY HOUSE - CONVERTED INTO 4 APARTMENTS WITH NO DRAWINGS OR PERMITS ON FILE 157 E KENSINGTON AVE COMPLAINT FAILED View