Chicago Building Violations Data: 5 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION VACANT BUILDING INT. NO ISPECTION OR FOUNDATION BUILDING APPEARS TO BE LEANING 1122 N HAMLIN AVE COMPLAINT PASSED View
REPLACE D&H PORCH FRONT 1-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. COLUMNS - ROTTING WOOD. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PERMIT REQUIRED FOR FRONT PORCH REPLACEMENT.REAR 2-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. COLUMNS - ROTTING WOOD. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPLACEMENT. 1122 N HAMLIN AVE COMPLAINT FAILED View
REPLACE D&H PORCH FRONT 1-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. COLUMNS - ROTTING WOOD. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PERMIT REQUIRED FOR FRONT PORCH REPLACEMENT.REAR 2-STORY WOOD PORCH - ALL COLUMNS ERECTED ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. COLUMNS - ROTTING WOOD. ALL DECKING WEAK WITH ROTTING WOOD. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND AT COLUMNS WITH NAILS ONLY. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; ATTACHED TO COLUMNS AND BUILDING'S WALLS WITH NAILS ONLY. TREADS - WORN OUT, CRACKED AND WEAK. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPLACEMENT. 1122 N HAMLIN AVE COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT AND ATTIC WITHOUT A PERMIT. 1122 N HAMLIN AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERNATIONS TO BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 1122 N HAMLIN AVE COMPLAINT PASSED View