| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| VACANT BUILDING - REGISTER | 12049 S WALLACE ST | COMPLAINT | CLOSED | View | |
| REPAIR EXTERIOR STAIR | WEST WOOD STAIRS HAS LOOSE/BROKEN HANDRAILS ROTTED 4X4 POSTS SOUTH WOOD STAIRS HAS ROTTED, WORN HANDRAILS, UNDERSIZED GUARDRAILS | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | REFUSED ENTRY TO INTERIOR | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN THE BASEMENT WITHOUT A PERMIT | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| MINI BREAKERS ARE NOT APPROVED FOR USE IN ELECTRICAL PANELS 18-27-240.85 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| NO PERMIT WIRING | OBTAIN PERMIT FOR ELECTRICAL WIRING AND EQUIPMENT INSTALLED WITHOUT A PERMIT | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| INSTALL VENT PIPE FOR TRAP | REMOVE S-TRAP USED FOR KITCHEN SINK AND INSTALL PROPER VENT FOR SINK TRAP | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT VIOLATIONS | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| RMV PLBFIX INSTALLD W/0 PERMIT | BASEMENT- REMOVE KITCHEN SINK, WATER, WASTE, AND VENT INSTALLED WITHOUT A PERMIT | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| SERVICE DROP OUT OF REACH | SERVICE DROP LYING ON REAR PORCH ROOF, A DANGEROUS AND HAZARDOUS CONDITION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| APPLIANCE INSIGHT DISCONNECT | PROVIDE DISCONNECTING MEANS FOR ELECTRICAL WATER HEATER IN BASEMENT AREA | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| PROVIDE PERMIT TO CORRECT VIOLATIONS 13-12-360 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| PROVIDE LOAD CALCULATIONS FOR FEEDERS, SERVICES, AND REQUIRED EQUIPMENT DUE TO ELECTRICAL HEATERS BEING INSTALLED THROUGHOUT BASEMENT AND 1ST FLOOR AREAS WITHOUT PERMITS 18-27-215.5 18-27-220 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| EXPOSE FOR INSPECT APPROVAL | OPEN ALL PLUMBING WALLS FOR INSPECTION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| REPAIR INTERIOR STAIR SYSTEM | STAIRS, 1ST FLOOR TO BASEMENT LOOSE, FRACTURED THREADS, 1ST STEP FROM BASEMENT 14 INCH HIGH RISER. | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| REPLACE DEFECTIVE WASTE PIPING | DISCONNECT WASTE PIPE TIED INTO THE 4 INCH CLOSET BED SIDE INLET, PLUG OPENING AFTER REMOVING WASTE LINE | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| STRAP SERVICE CONDUIT | SERVICE RISER NOT PROPERLY SUPPORTED DANGEROUS AND HAZARDOUS CONDITION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS, BATHROOMS, AND LAUNDRY AREAS OF BASEMENT AND 1ST FLOOR AREAS 18-27-210.8 | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR ARMOURED CABLE IN 1/2 INCH CONDUIT THROUGHOUT THE BASEMENT AREAS DANGEROUS AND HAZARDOUS CONDITION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| EXTEND SOIL/WASTE THRU ROOF | INSTALL A VENT FOR A WASHER WASTE PIPING AT FIRST FLOOR | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| SEE INSPECTOR COMMENTS | INSTALL WEATHERPROOF RACEWAY, BOXES, FITTINGS, AND FIXTURES THROUGHOUT ENTIRE EXTERIOR 18-27-300.6 A | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| ALL ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER THROUGHOUT ALL BASEMENT AND 1ST FLOOR AREAS. 18-27-110.12 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| CONTRARY TO ORIGINAL PLAN | BASEMENT ORIGINALLY STORAGE AND HEATING PLANT AREAS, WALLS NOW FRAMED FOR BEDROOMS AND KITCHEN AREAS | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| CLOSET LIGHT NEEDS TO TOTALLY ENCLOSED LAMP TYPE FIXTURE 18-27-410.8 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL WATER, WASTE, AND VENT INSTALLED WITHOUT A PERMIT | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| ADD RECEPTACLES | ADD ADDITIONAL RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT THE FIRST FLOOR AREAS | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| REPLACE DEFECTIVE WATER PIPING | INSTALL AIR CHAMBERS FOR ALL PLUMBING FIXTURES | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| NO PERMIT WIRING | OBTAIN PERMIT FOR ELECTRICAL WIRING AND EQUIPMENT INSTALLED WITHOUT PERMIT IN BASEMENT AND 1ST FLOOR AREAS 13-12-360 | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT FOR PLUMBING | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | FRONT PORCH WITH THE FOLLOWING DEFECTS; 1) STRINGERS OVER CUT; 2) STRINGERS INSTALLED ON OUTSIDE OF SUPPORT COLUMNS AND NAILED ONLY; 3) STRINGERS BACH PITCHED; 4) INCONSISTENT RISER HEIGHTS; 5)4X4 COLUMNS WITH NO VISIBLE FOOTINGS; 6) LANDING ATTACHED TO ORIGINAL ENCLOSED PORCH, LEDGERSCREWED TO ONE ONLY; 7) NO PLANS OR PERMITS OBTAINED FOR INSTALLATION; REAR PORCH WITH THE FOLLOWING DEFECTS; 1) STRINGERS INSTALLED ON OUTSIDE OF SUPPORT COLUMNS; 2) ALL 4X4 COLUMNS WITH NO VISIBLE FOOTINGS, REAR 4X4 COLUMNS REST ON STAIRWELL SLAB; 3) 2X8 LEDGER ATTACHED TO ORIGINAL ENCLOSED PORCH, LRDGER PORTION DETACHED; 4)NO PLANS AND PERMITS ON FILE FOR INSTALLATION; ENCLOSED REAR PORCH WITH THE FOLLOWING DEFECTS ; 1) 2X6 JOIST OVER SPANNED, 10 FEET; 2) 6X6 SUPPORT COLUMNS ROTTED AT BASE AND NO VISIBLE FOOTINGS | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| DEFECTIVE LIGHTING SERVICE | ADDITIONAL NON-FUSED AND NON-METERED SERVICE ADDED VIA UNAPPROVED TAP TO SERVICE DROP, DANGEROUS AND HAZARDOUS CONDITION. | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT THROUGHOUT THE BASEMENT AND 1ST FLOOR AREA WITHOUT ROUGH INSPECTION / ROUGH INSPECTION REQUIRES CEILING AND WALLS TO BE OPEN 12-13-380 | 12049 S WALLACE ST | COMPLAINT | FAILED | View | |
| PROPER SIXE SOIL/WASTE PIPE | RE-PIPE SOIL STACK TO FULL 4 INCHES WITH FULL SIZE CLEAN OUT AT BASE OF STACK | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| INSTALL ILLUMINATION | INSTALL WEATHERPROOF ILLUMINATION AT ALL EXTERIOR ENTRIES | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| INSTALL COVERS | OPEN BOXES AND WIRES HANGING OUT BELOW PORCH AND ELSEWHERE AT REAR EXTERIOR, DANGEROUS AND HAZARDOUS CONDITION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |
| SPLICE IN CORD | OPEN AIR SPLICE IN EXTENSION CORD BEING USED TO SUPPLY ADJACENT BUILDING DANGEROUS AND HAZARDOUS CONDITION | 12049 S WALLACE ST | COMPLAINT | FAILED | View |