Chicago Building Violations Data: 37 Violations
Violation Inspector Comments Address Category Status View
VACANT BUILDING - REGISTER 12049 S WALLACE ST COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR WEST WOOD STAIRS HAS LOOSE/BROKEN HANDRAILS ROTTED 4X4 POSTS SOUTH WOOD STAIRS HAS ROTTED, WORN HANDRAILS, UNDERSIZED GUARDRAILS 12049 S WALLACE ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION REFUSED ENTRY TO INTERIOR 12049 S WALLACE ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN THE BASEMENT WITHOUT A PERMIT 12049 S WALLACE ST COMPLAINT FAILED View
MINI BREAKERS ARE NOT APPROVED FOR USE IN ELECTRICAL PANELS 18-27-240.85 12049 S WALLACE ST COMPLAINT FAILED View
NO PERMIT WIRING OBTAIN PERMIT FOR ELECTRICAL WIRING AND EQUIPMENT INSTALLED WITHOUT A PERMIT 12049 S WALLACE ST COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP REMOVE S-TRAP USED FOR KITCHEN SINK AND INSTALL PROPER VENT FOR SINK TRAP 12049 S WALLACE ST COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT VIOLATIONS 12049 S WALLACE ST COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT BASEMENT- REMOVE KITCHEN SINK, WATER, WASTE, AND VENT INSTALLED WITHOUT A PERMIT 12049 S WALLACE ST COMPLAINT FAILED View
SERVICE DROP OUT OF REACH SERVICE DROP LYING ON REAR PORCH ROOF, A DANGEROUS AND HAZARDOUS CONDITION 12049 S WALLACE ST COMPLAINT FAILED View
APPLIANCE INSIGHT DISCONNECT PROVIDE DISCONNECTING MEANS FOR ELECTRICAL WATER HEATER IN BASEMENT AREA 12049 S WALLACE ST COMPLAINT FAILED View
PROVIDE PERMIT TO CORRECT VIOLATIONS 13-12-360 12049 S WALLACE ST COMPLAINT FAILED View
PROVIDE LOAD CALCULATIONS FOR FEEDERS, SERVICES, AND REQUIRED EQUIPMENT DUE TO ELECTRICAL HEATERS BEING INSTALLED THROUGHOUT BASEMENT AND 1ST FLOOR AREAS WITHOUT PERMITS 18-27-215.5 18-27-220 12049 S WALLACE ST COMPLAINT FAILED View
EXPOSE FOR INSPECT APPROVAL OPEN ALL PLUMBING WALLS FOR INSPECTION 12049 S WALLACE ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM STAIRS, 1ST FLOOR TO BASEMENT LOOSE, FRACTURED THREADS, 1ST STEP FROM BASEMENT 14 INCH HIGH RISER. 12049 S WALLACE ST COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING DISCONNECT WASTE PIPE TIED INTO THE 4 INCH CLOSET BED SIDE INLET, PLUG OPENING AFTER REMOVING WASTE LINE 12049 S WALLACE ST COMPLAINT FAILED View
STRAP SERVICE CONDUIT SERVICE RISER NOT PROPERLY SUPPORTED DANGEROUS AND HAZARDOUS CONDITION 12049 S WALLACE ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS, BATHROOMS, AND LAUNDRY AREAS OF BASEMENT AND 1ST FLOOR AREAS 18-27-210.8 12049 S WALLACE ST COMPLAINT FAILED View
CONTINUITY OF RACEWAY PROVIDE GROUND CONTINUITY FOR ARMOURED CABLE IN 1/2 INCH CONDUIT THROUGHOUT THE BASEMENT AREAS DANGEROUS AND HAZARDOUS CONDITION 12049 S WALLACE ST COMPLAINT FAILED View
EXTEND SOIL/WASTE THRU ROOF INSTALL A VENT FOR A WASHER WASTE PIPING AT FIRST FLOOR 12049 S WALLACE ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS INSTALL WEATHERPROOF RACEWAY, BOXES, FITTINGS, AND FIXTURES THROUGHOUT ENTIRE EXTERIOR 18-27-300.6 A 12049 S WALLACE ST COMPLAINT FAILED View
ALL ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER THROUGHOUT ALL BASEMENT AND 1ST FLOOR AREAS. 18-27-110.12 12049 S WALLACE ST COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN BASEMENT ORIGINALLY STORAGE AND HEATING PLANT AREAS, WALLS NOW FRAMED FOR BEDROOMS AND KITCHEN AREAS 12049 S WALLACE ST COMPLAINT FAILED View
CLOSET LIGHT NEEDS TO TOTALLY ENCLOSED LAMP TYPE FIXTURE 18-27-410.8 12049 S WALLACE ST COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT REMOVE ALL WATER, WASTE, AND VENT INSTALLED WITHOUT A PERMIT 12049 S WALLACE ST COMPLAINT FAILED View
ADD RECEPTACLES ADD ADDITIONAL RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT THE FIRST FLOOR AREAS 12049 S WALLACE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT 12049 S WALLACE ST COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING INSTALL AIR CHAMBERS FOR ALL PLUMBING FIXTURES 12049 S WALLACE ST COMPLAINT FAILED View
NO PERMIT WIRING OBTAIN PERMIT FOR ELECTRICAL WIRING AND EQUIPMENT INSTALLED WITHOUT PERMIT IN BASEMENT AND 1ST FLOOR AREAS 13-12-360 12049 S WALLACE ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMIT FOR PLUMBING 12049 S WALLACE ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH WITH THE FOLLOWING DEFECTS; 1) STRINGERS OVER CUT; 2) STRINGERS INSTALLED ON OUTSIDE OF SUPPORT COLUMNS AND NAILED ONLY; 3) STRINGERS BACH PITCHED; 4) INCONSISTENT RISER HEIGHTS; 5)4X4 COLUMNS WITH NO VISIBLE FOOTINGS; 6) LANDING ATTACHED TO ORIGINAL ENCLOSED PORCH, LEDGERSCREWED TO ONE ONLY; 7) NO PLANS OR PERMITS OBTAINED FOR INSTALLATION; REAR PORCH WITH THE FOLLOWING DEFECTS; 1) STRINGERS INSTALLED ON OUTSIDE OF SUPPORT COLUMNS; 2) ALL 4X4 COLUMNS WITH NO VISIBLE FOOTINGS, REAR 4X4 COLUMNS REST ON STAIRWELL SLAB; 3) 2X8 LEDGER ATTACHED TO ORIGINAL ENCLOSED PORCH, LRDGER PORTION DETACHED; 4)NO PLANS AND PERMITS ON FILE FOR INSTALLATION; ENCLOSED REAR PORCH WITH THE FOLLOWING DEFECTS ; 1) 2X6 JOIST OVER SPANNED, 10 FEET; 2) 6X6 SUPPORT COLUMNS ROTTED AT BASE AND NO VISIBLE FOOTINGS 12049 S WALLACE ST COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE ADDITIONAL NON-FUSED AND NON-METERED SERVICE ADDED VIA UNAPPROVED TAP TO SERVICE DROP, DANGEROUS AND HAZARDOUS CONDITION. 12049 S WALLACE ST COMPLAINT FAILED View
INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT THROUGHOUT THE BASEMENT AND 1ST FLOOR AREA WITHOUT ROUGH INSPECTION / ROUGH INSPECTION REQUIRES CEILING AND WALLS TO BE OPEN 12-13-380 12049 S WALLACE ST COMPLAINT FAILED View
PROPER SIXE SOIL/WASTE PIPE RE-PIPE SOIL STACK TO FULL 4 INCHES WITH FULL SIZE CLEAN OUT AT BASE OF STACK 12049 S WALLACE ST COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL WEATHERPROOF ILLUMINATION AT ALL EXTERIOR ENTRIES 12049 S WALLACE ST COMPLAINT FAILED View
INSTALL COVERS OPEN BOXES AND WIRES HANGING OUT BELOW PORCH AND ELSEWHERE AT REAR EXTERIOR, DANGEROUS AND HAZARDOUS CONDITION 12049 S WALLACE ST COMPLAINT FAILED View
SPLICE IN CORD OPEN AIR SPLICE IN EXTENSION CORD BEING USED TO SUPPLY ADJACENT BUILDING DANGEROUS AND HAZARDOUS CONDITION 12049 S WALLACE ST COMPLAINT FAILED View