Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL SMOKE DETECTORS | SMOKE DETECTOR MISSING - 6324 INERIOR ENTRANCE STAIRWAY | 6324 N BELL AVE | PERIODIC | PASSED | View |
DEBRIS, EXCESSIVE | JUNK & DEBRIS ACCUMULATION - 6324-26 INTERIOR STAIR & REAR PORCH SYSTEMS | 6324 N BELL AVE | PERIODIC | PASSED | View |
STOP LEAKING WATER | BATHROOM SINK LEAKING - 6326 APT. 2A | 6324 N BELL AVE | PERIODIC | PASSED | View |
ROACHES | ROACHING INFESTING 6326 APT. 2A, 1B | 6324 N BELL AVE | PERIODIC | PASSED | View |
DEFECTIVE OUTLETS | BROKEN WALL OUTLET @ THE KITCHEN 6326 APT. 2A | 6324 N BELL AVE | PERIODIC | PASSED | View |
ABANDONED REFRIGERATOR | REFRIGERATOR STORED ON 6326 INTERIORS STAIRWAY 3RD FLOOR | 6324 N BELL AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCHES - 6324-26 GUARDRAILS <42" HIGH, RAILINGS MISSING PICKETS LEDGERS NOT BOLTED, RAILINGS <32" HIGH. BSMT TO GRADE STAIRS MISSING HANDRAILS | 6324 N BELL AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | REAR EXIT DOOR TO THE PORCH - RESET. | 6324 N BELL AVE | PERIODIC | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT TO REPAIR THE REAR PORCHES | 6324 N BELL AVE | PERIODIC | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT WALKWAY BROKEN CONCRETE | 6324 N BELL AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | FRONT HALLWAY DEBRIS | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NEED ENTRY TO INSPECT BUILDING | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NO HANDRAIL REAR BASEMENT STAIRS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
MICE/RODENTS | UNIT 2A 6326 - MICE DROPPINGS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | BROKEN SIDING WEST ELEVATION. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | BATHROOM FLOOR TILE - BROKEN TILE - GAPS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR TOP 6324 REAR STAIRS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | STORAGE UNDER 6324 REAR STAIRS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 6324 REAR PORCH LOOSE GUARDRAIL AT 3 AND 2. 6324 REAR SOUTH PORCH - INSUFFICIENT STAIR WIDTH. REAR STAIRS 32" WIDE. ROTTING AND BUCKLING DECKING AT 2 AND 3, ROTTING TREAD BEFORE 3. MISSING JOIST HANGERS WHERE JOISTS CONNECTION. BEAMS INSTEAD OF MASONRY POCKETS. PITCHED STAIRS, UNDERSIZED JOISTS FOR SPAN. NO LEDGER BOLTS OR JOIST HANGERS UNDER 1. INSUFFICIENT STRINGER CONNECTIONS. WEST REAR PORCH MISSING JOISTS HANGERS, LOOSE AND ROTTING DECKING, INSUFFICIENT STRINGER TO OTHER WOOD MEMBER CONNECTIONS. OUT OF LEVEL LANDINGS AND DECKS. STACKED COLUMNS. ROTTING BEAM AND STRINGER BEFORE 2. INSUFFICIENT BEAM TO COLUMN CONNECTIONS. ROTTING RAILINGS AND POSTS. OBTAIN PLANS AND PERMITS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | REAR ENCLOSED PORCHES NO 1 HR. ENCLOSURE. | 6324 N BELL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2005-2007. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NO HANDRAIL REAR BASEMENT STAIRS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | APARTMENT 2B/BEDROOM-MISSING CARBON MONOXIDE DETECTOR | 6324 N BELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | APARTMENT B/BEDROOM-LOOSE PLASTER ON CEILING | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BOILER ROOM/CEILING - LARGE HOLE | 6324 N BELL AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER ROOM/DOOR - NOT CLASS B | 6324 N BELL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BOILER ROOM - MISSING SMOKE DETECTOR. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR RECENT DRYWALL ADDED TO REAR PORCH. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | APARTMENT B/BEDROOM-LOOSE PLASTER ON CEILING | 6324 N BELL AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER ROOM/DOOR - NOT CLASS B | 6324 N BELL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BOILER ROOM - MISSING SMOKE DETECTOR. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT REQUIRED FOR RECENT DRYWALL ADDED TO REAR PORCH. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR NEW PORCH AT 6326. | 6324 N BELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | APARTMENT B/BEDROOM-LOOSE PLASTER ON CEILING | 6324 N BELL AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER ROOM/DOOR - NOT CLASS B | 6324 N BELL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BOILER ROOM - MISSING SMOKE DETECTOR. | 6324 N BELL AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT KITCHEN FLOOR SINKING. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR 3 STORY WOOD PORCH CONSTRUCTED WITHOUT SUBMITTING PLANS AND OBTAINING PERMIT. | 6324 N BELL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2009 THROUGH 2013. | 6324 N BELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | APARTMENT B/BEDROOM-LOOSE PLASTER ON CEILING | 6324 N BELL AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER ROOM/DOOR - NOT CLASS B | 6324 N BELL AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BOILER ROOM - MISSING SMOKE DETECTOR. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT KITCHEN FLOOR SINKING. | 6324 N BELL AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR 3 STORY WOOD PORCH CONSTRUCTED WITHOUT SUBMITTING PLANS AND OBTAINING PERMIT. | 6324 N BELL AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2009 THROUGH 2013. | 6324 N BELL AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | EAST ELEVATION FRONT GATE DOUBLE KEY LOCK. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 6326 UNIT 1 TO VERIFY COMPLAINT OF MOLD.UNABLE TO GAIN ENTRY TO VERIFY EXISTING VIOLATIONS.UNABLE TO GAIN ENTRY TO MOST APARTMENTS TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR. UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR AND SPALLING BRICKS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ALL DWELLING UNITS - NO RESPONSE, UNABLE TO VERIFY DETECTORS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCK - 6324-26 FRONT ENTRANCE GATES. | 6324 N BELL AVE | PERIODIC | PASSED | View |
REPAIR DOOR HARDWARE | REAR DOOR LOCK DEFECTIVE 6326 APT. 2A. | 6324 N BELL AVE | PERIODIC | PASSED | View |
REPAIR FLOOR | APARTMENT 2B/KITCHEN-BROKEN FLOOR TILES. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ROACHES | UNIT 2A 6326 - ROACHES. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | FRONT BUILDING ENTRY DOORS (TWO) - DEFECTIVE LOCKS. | 6324 N BELL AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT INTERIOR STAIRWAY AT 6324 N./, WALLS - BUCKLING PLASTER. | 6324 N BELL AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | FRONT BUILDING FOYERS - REFUSE ACCUMULATION. | 6324 N BELL AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | NORTH GANGWAY & FRONT YARD - REFUSE ACCUMULATION. | 6324 N BELL AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - STEP CRACK. | 6324 N BELL AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING MOST APTS. - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. | 6324 N BELL AVE | PERIODIC | FAILED | View |