| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| INSTALL SMOKE DETECTORS | BUILDING - 1ST FLOOR AND UPPER LEVEL MISSING SMOKE DETECTORS | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| CARB MONOX DETECT IN RESID | BUILDING - 1ST FLOOR AND BASEMENT MISSING C.O. DETECTORS | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| REPAIR FLOOR | INTERIOR OF BUILDING - ENTIRE 1ST FLOOR JOISTS - STRUCTURAL INTEGRITY COMPROMISED WITH SUBSTANDARD REPAIRS THROUGHOUT FROM PAST FIRE DAMAGE. DANGEROUS AND HAZARDOUS. UPPER LEVELS SHOWING SIGNS OF POSSIBLE COLLAPSE. ALL STRUCTURAL JOINTS TO LEDGER RAIL ATTACHED TO 6X6 BEAM - PULLING WITH GAPS OVER 1 IN. WITH 2X4'S REPLACING 2X8 (REPAIR) JOISTS AT REAR PORTION OF BUILDING. REQUESTING A VACATE | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| SUBMIT STRUCT. ENG. RPT (INT.) | SUBMIT PLANS PREPARED SIGNED AND SEALED BY A LICENSED ARCHITECT OR REGISTERED STRUCTURAL ENGINEER FOR APPROVAL AND OBTAIN PERMIT | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING INSTALLED WITHOUT A PERMIT | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| PROPER MATRL WATER SUPPLY PIPE | REPLACE ALL PLASTIC WASTE SUPPLIES TO FIXTURES | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| APPLIANCE INSIGHT DISCONNECT | PROVIDE DISCONNECT IN SIGHT OF ELECTRIC WATER HEATER | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| SEE INSPECTOR COMMENTS | PROVIDE THE PROPER COLOR CODE FOR UNGROUNDED CONDLUCTORS OF MULTI-WIRE BRANCH CIRCUIT FOR ELECTRIC WATER HEATER 18-27-210.5 | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRIC CONDUIT BOXES, WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AND 1ST FLOOR AREAS 13-12-380 | 430 N AVERS AVE | COMPLAINT | PASSED | View | |
| CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES TO LIGHT FIXTURE IN BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION* | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 13-12-360 | 430 N AVERS AVE | COMPLAINT | PASSED | View | |
| VACANT BUILDING - REGISTER | 430 N AVERS AVE | COMPLAINT | CLOSED | View | |
| REPLACE DEFECTIVE WASTE PIPING | REMOVE RUBBER COUPLING ON 1 1/2 IN. WASTE TIE-IN FOR FIRST FLOOR BATHROOM | 430 N AVERS AVE | COMPLAINT | FAILED | View |
| PRV DISCHARGE PIPE FROM PRV | WATER HEATER - NO RELIEF VALVE PIPING | 430 N AVERS AVE | COMPLAINT | FAILED | View |
| REPLACE DEFECTIVE WATER PIPING | WATER HEATER - 3/4 IN. DIALECTIC UNION LEAKING, REPLACE | 430 N AVERS AVE | COMPLAINT | FAILED | View |
| INSTALL FIXTURES PROPERLY | OVER CUT BOTTOM FIVE FLOOR JOISTS FOR WASTE ARM, REPLACE JOISTS | 430 N AVERS AVE | COMPLAINT | PASSED | View |
| REPLACE DEFECTIVE WASTE PIPING | BASEMENT - REMOVE 1 1/2 IN. WASTE PIPING TO FIRST FLOOR BATHROOM, INSTALLED WITH WRONG WASTE FITTINGS | 430 N AVERS AVE | COMPLAINT | FAILED | View |
| GROUND EQUIPMENT | PROVIDE WATER MAIN GROUND TO WITHIN 5 FFEET OF POINT OF ENTRY OF WATER METER OR VALVE | 430 N AVERS AVE | COMPLAINT | PASSED | View |