Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION NO ENTRY INTERIOR. UNABLE TO VERIFY DETECTORS AND OCCUPANCY. 5385 N BOWMANVILLE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR BASEMENT STAIR NO HANDRAIL. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR EXTERIOR 2 STORY WOOD PORCH; 2X6 JOISTS SPAN 10' INSTALLED AT 18'' CENTERS. SOME STRINGER CONNECTIONS MADE WITH NAILS AND/ OR SCREWS ONLY. 37 1/2'' GUARD RAILS,. CENTRAL STRINGER COLUMN NOT CONTINUOUS FROM GROUND TO 2. COLUMN SEATED ON DECK AT 1 AND CONTINUES TO CENTER OF BEAM AT 2 WHERE BEAM CONTILEVERED AND 4X4 STRINGER COLUMN SUSPENDED DOWN FOR CONNECTION AT WINDERS TO 2. SINGLE 2X6 STRINGER HEADERS FASTENED WITH NAILS AND/ OR SCREWS ONLY. POSTS AND RAILS FASTENED WITH NAILS AND/ OR SCREWS ONLY. SAGGING BEAMS AND JOISTS. OBTAIN PLAN AND PERMIT. 5385 N BOWMANVILLE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR 2 STORY WOOD PORCH; 2X6 JOISTS SPAN 10' INSTALLED AT 18'' CENTERS. SOME STRINGER CONNECTIONS MADE WITH NAILS AND/ OR SCREWS ONLY. 37 1/2'' GUARD RAILS,. CENTRAL STRINGER COLUMN NOT CONTINUOUS FROM GROUND TO 2. COLUMN SEATED ON DECK AT 1 AND CONTINUES TO CENTER OF BEAM AT 2 WHERE BEAM CONTILEVERED AND 4X4 STRINGER COLUMN SUSPENDED DOWN FOR CONNECTION AT WINDERS TO 2. SINGLE 2X6 STRINGER HEADERS FASTENED WITH NAILS AND/ OR SCREWS ONLY. POSTS AND RAILS FASTENED WITH NAILS AND/ OR SCREWS ONLY. SAGGING BEAMS AND JOISTS. OBTAIN PLAN AND PERMIT. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR OF PROPERTY. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR WEST STAIRS GRADE TO BASEMENT MISSING GUARD RAIL. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# MISSING OWNER POSTING. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
INSTALL ILLUMINATION INSTALL ILLUMINATION TO FRONT BASEMENT ENTRY DOOR AND GARAGE ENTRY DOOR. 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
INSTALL GFCI TO REAR OF BUILDING ON EXTERIOR. 18.27.210 5385 N BOWMANVILLE AVE COMPLAINT PASSED View
PROVIDE PERMIT TO CORRECT VIOLATIONS. 13-12-360 5385 N BOWMANVILLE AVE COMPLAINT PASSED View