Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR. UNABLE TO VERIFY DETECTORS AND OCCUPANCY. | 5385 N BOWMANVILLE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR BASEMENT STAIR NO HANDRAIL. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 2 STORY WOOD PORCH; 2X6 JOISTS SPAN 10' INSTALLED AT 18'' CENTERS. SOME STRINGER CONNECTIONS MADE WITH NAILS AND/ OR SCREWS ONLY. 37 1/2'' GUARD RAILS,. CENTRAL STRINGER COLUMN NOT CONTINUOUS FROM GROUND TO 2. COLUMN SEATED ON DECK AT 1 AND CONTINUES TO CENTER OF BEAM AT 2 WHERE BEAM CONTILEVERED AND 4X4 STRINGER COLUMN SUSPENDED DOWN FOR CONNECTION AT WINDERS TO 2. SINGLE 2X6 STRINGER HEADERS FASTENED WITH NAILS AND/ OR SCREWS ONLY. POSTS AND RAILS FASTENED WITH NAILS AND/ OR SCREWS ONLY. SAGGING BEAMS AND JOISTS. OBTAIN PLAN AND PERMIT. | 5385 N BOWMANVILLE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 2 STORY WOOD PORCH; 2X6 JOISTS SPAN 10' INSTALLED AT 18'' CENTERS. SOME STRINGER CONNECTIONS MADE WITH NAILS AND/ OR SCREWS ONLY. 37 1/2'' GUARD RAILS,. CENTRAL STRINGER COLUMN NOT CONTINUOUS FROM GROUND TO 2. COLUMN SEATED ON DECK AT 1 AND CONTINUES TO CENTER OF BEAM AT 2 WHERE BEAM CONTILEVERED AND 4X4 STRINGER COLUMN SUSPENDED DOWN FOR CONNECTION AT WINDERS TO 2. SINGLE 2X6 STRINGER HEADERS FASTENED WITH NAILS AND/ OR SCREWS ONLY. POSTS AND RAILS FASTENED WITH NAILS AND/ OR SCREWS ONLY. SAGGING BEAMS AND JOISTS. OBTAIN PLAN AND PERMIT. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF PROPERTY. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | WEST STAIRS GRADE TO BASEMENT MISSING GUARD RAIL. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER POSTING. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO FRONT BASEMENT ENTRY DOOR AND GARAGE ENTRY DOOR. | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |
INSTALL GFCI TO REAR OF BUILDING ON EXTERIOR. 18.27.210 | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View | |
PROVIDE PERMIT TO CORRECT VIOLATIONS. 13-12-360 | 5385 N BOWMANVILLE AVE | COMPLAINT | PASSED | View |