Last Modification Date: 2024-10-22 @ 7:24 PM
PIN: 11323060080000
Property Address: 1301 W COLUMBIA AVE
City - Zip: CHICAGO - 60626
2023 Property Class: 315
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75060
2023 Tax District: 75001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 22 Violations
Violation Inspector Comments Address Category Status View
SYSTEM III PROVIDE EM LITES IN ALL STAIRWAYS CORRIDORS AND COMMON AREA'S OF BUILDING 1301 W COLUMBIA AVE COMPLAINT PASSED View
DEFECTIVE LIGHTING SERVICE DETERIORATED CABLES AT SERVICE HEAD AND RUSTED OUT RISER SUPPORTS 1301 W COLUMBIA AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES IN ALL ENTRANCE AREA'S AND STAIRWAYS 1301 W COLUMBIA AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE THE REQUIRED DIAGRAM AND LOAD CALCULATIONS FOR FEEDERS SERVICES AND REQUIRED EQUIPMENT,IN ADEQUATE SERVICE SIZE,18-27-215.5 AND 18-27-220 1301 W COLUMBIA AVE COMPLAINT PASSED View
DEBRIS, EXCESSIVE WEST GANG WAY- FULL OF BRUSH, LEAVES, WOOD, DEBRIS, STORAGE. UNDER REAR PORCHES- STORAGE OF GARBAGE, PLASTIC BAGS FULL OF TRASH, WOOD, DOORS, FISH TANKS, BOXES, FURNITURE, DEBRIS. BASEMENTS, BOILER ROOM- FULL OF DEBRIS- GARBAGE, WOOD PILES, BOXES, FURNITURE, OLD BUILDING SUPPLIES, MATTRESSES, GARBAGE BAGS. FIRE HAZARD THROUGHOUT- MOST NOTABLY IN BOILER ROOM. DEBRIS PILED FROM FLOOR TO CEILING IN NUMEROUS LOCATIONS. 1301 W COLUMBIA AVE COMPLAINT FAILED View
RATS RAT HARBOR THROUGHOUT BASEME, AND EXTERIOR GANG WAY AND UNDER PORCHES- STORAGE OF EXCESSIVE GARBAGE AND DEBRIS. 1301 W COLUMBIA AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR INTERIOR STAIRS AT BASEMENT WITH STORAGE OF BOXES, BAGS, FURNITURE, GARBAGE. REAR PORCHES WITH STORAGE BENEATH- WOOD, FURNITURE, DOORS, GARBAGE, BAGS. 1301 W COLUMBIA AVE COMPLAINT FAILED View
UNSANITARY CONDITIONS-ANIMALS BASEMENT AREAS, REAR PORCHES AND BENEATH REAR PORCHES- STRONG ODORS OF ANIMALS AND URINE. 1301 W COLUMBIA AVE COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT BASEMENT SOUTH END AND CENTRAL AREA WITH STANDING WATER ON SLAB. 1301 W COLUMBIA AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY BOTH REAR PARTIALLY ENCLOSED PORCHES WITH STORAGE AND DEBRIS AT LANDINGS OBSTRUCTING TRAVEL. 1301 W COLUMBIA AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM LAKEWOOD REAR PORCH- ROTTING GUARD RAILS AROUND BASEMENT WELL, LOOSE AND MISSING PICKETS. LANDING COLUMNS WITH CONCRETE POURED AROUND BASE OF COLUMN. WORN AND ROTTING TREADS. STRINGERS ANCHORED TO COLUMNS, POSTS AND WALLS WITH NAILS ONLY. POSTS ANCHORED WITH NAILS ONLY. ROTTING BEAMS AT FIRST LANDING. JOIST HANGERS MISSING FASTENERS. RAILS ANCHORED WITH NAILS ONLY. BUTT JOINT 6X6 COLUMN SPLICES ANCHORED WITH NAILS ONLY. INTERIOR BEAM TO COLUMN CONNECTION AT 3 FASTENED WITH NAILS ONLY. ROTTING PORCH ROOF DECKING. SINGLE 2X8 STRINGER HEADERS SPAN 7' 2''. COLUMBIA PARTIALLY ENCLOSED REAR PORCH- STRINGERS, RAILS, COLUMN, POSTS, WINDERS, BEAMS, JOISTS, ALL ANCHORED WITH NAILS ONLY. WORN AND ROTTING TREADS. OBTAIN PLAN AND PERMIT FOR REAR PORCHES REPAIR OR REPLACEMENT. 1301 W COLUMBIA AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR AT TOP OF PARTIALLY ENCLOSE COLUMBIA PORCH. NO SMOKE DETECTOR BOILER ROOM. 1301 W COLUMBIA AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR IN BOILER ROOM OR BASEMENT. NO CARBON MONOXIDE DETECTOR 6720 APARTMENT 1. 1301 W COLUMBIA AVE COMPLAINT FAILED View
CONTRARY TO PLANS/OUT OF SCOPE PORCHES NOT REPAIRED ACCORDING TO APPROVED PLANS AND ISSUED PERMITS 100135975 AND 100064081 ISSUED IN 2005 AND 2006. FINAL INSPECTIONS NEVER OBTAINED AND VIOLATIONS NOT COMPLIED. 1301 W COLUMBIA AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING NEVER REGISTERED. 1301 W COLUMBIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION PORCH ENCLOSURE- MISSING AND LOOSE, HANGING SIDING. EXTERIOR DRYWALL WITH WATER DAMAGE VISIBLE FROM INSIDE OF PORCH. SOUTH ELEVATION MASONRY GUARD WALL WITH LOOSE, MISSING AND SPALLING BRICK. ERODED MORTAR, OPEN MORTAR JOINTS. 1301 W COLUMBIA AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION REAR BASEMENT WELL FOUNDATIONS- FRACTURES. 1301 W COLUMBIA AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH 6720 APARTMENT 1 AT REAR ENCLOSED PORCH SLIDING GLASS DOORS INSTALLED AS PERMITED BY PREVIOUS APPROVED PLANS BUT NO GUARD RAIL INSTALLED TO PREVENT RESIDENT FROM FALLING OUT SLIDING GLASS DOORS WHICH ARE NOT EXITS. 1301 W COLUMBIA AVE COMPLAINT FAILED View
PARAPET SOUTH ELEVATION EAST AND WEST ENDS- FRACTURES, ERODING MORTAR. WEST PARAPET WALL SOUT END- ERODED MORTAR. 1301 W COLUMBIA AVE COMPLAINT FAILED View
STOP SMOKE, NOXIOUS ODORS BASEMENT AREAS- STRONG ODOR OF URINE AND MILDEW/ MOLD. 1301 W COLUMBIA AVE COMPLAINT FAILED View
STOP LEAKING WATER BASEMENT SOUTH END- WATER DRIPPING FROM CEILING FROM 1RST FLOOR PLUMBING. 1301 W COLUMBIA AVE COMPLAINT FAILED View
INSECTS BASEMENT AREAS WITH FLYING INSECTS. 1301 W COLUMBIA AVE COMPLAINT FAILED View