Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 8:24 PM
PIN: 14283140020000
Property Address: 647 W DEMING PL
City - Zip: CHICAGO - 60614
2023 Property Class: 315
2023 Township: 73 - Lake View
2023 Neighborhood: 73063
2023 Tax District: 73105
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 7 Violations
Violation Inspector Comments Address Category Status View
BLANK-TEXT MUST CITE CODE SECT 647 W DEMING PL PERMIT PASSED View
REPAIR EXTERIOR WALL FRONT, REAR, AND EAST ELEVATION /BRICKS - STEP CRACKS WITH WASHED OUT MORTAR. PERMITS REQUIRED FOR MASONRY REPAIRS TO EXTERIOR WALL. 647 W DEMING PL PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR ELEVATION - 3 STORY WOODEN PORCH /TREADS - CRACKING NEAR TOP FLOORS. /STRINGERS - SCREWED ONLY. /DECKING - LOOSE AND LIFTED AT TOP FLOOR. /LANDING - SWAY AT 3RD FL LANDING. PLANS AND PERMITS REQUIRED FOR REPAIRS TO PORCH SYSTEM. 647 W DEMING PL PERIODIC FAILED View
PROVIDE PROVIDE PER SECTION CODE 14A-6-603.4 THROUGH 14A-6-603.5. METAL PORCH AND BALCONIES AT FRONT ELEVATIONS. PROVIDE CRITICAL EXAMINATION OF PORCH, BALCONIES, AND SUPPORT STRUCTURES WITHIN 1 YEAR AFTER INSTALLATION AND AT LEAST ONCE EVERY 2 YEARS AFTER THE INITIAL INSPECTION. THE REGISTERED DESIGN PROFESSIONAL MUST PREPARE THE SIGNED AND SEALED WRITTEN REPORT ON THE EXTERNAL STRUCTURAL CONDITION AND INTEGRITY OF THE EXPOSED METAL STRUCTURE AND PROVIDE TO OWNER. PORCH, BALCONIES, AND THEIR SUPPORTING STRUCTURES MUST BE MAINTAINED IN GOOD REPAIR AND BE PROPERLY ANCHORED. METAL SURFACES SUBJECT TO RUST OR CORROSION MUST BE COATED TO INHIBIT SUCH RUST AND CORROSION, AND SURFACES WITH RUST OR CORROSION MUST BE STABILIZED AND COATED TO INHIBIT FUTURE RUST AND CORROSION. SEND REPORTS TO: DEPARTMENT OF BUILDINGS CODE COMPLIANCE GROUP, 2045 W. WASHINGTON BLVD. CHICAGO, IL 60612. (14A-6-603.4 THROUGH 14A-6-603.5, 14A-6-604.3, 14X-3-303.2 AND 14X-3-303.9) 647 W DEMING PL PERIODIC FAILED View
REPAIR PORCH SYSTEM FRONT METAL PORCH - RUSTED AREAS. 647 W DEMING PL PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS. 647 W DEMING PL PERIODIC FAILED View
ARRANGE PERMIT INSP. 647 W DEMING PL PERMIT PASSED View