Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR FLOOR | 4845 GARDEN UNIT WITH CRAKED KITCHEN FLOOR TILES | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | 4845 GARDEN UNIT FRONT ENTRY DOOR 29 INCH WIDTH, MINIMUM IS 32 INCH | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
WINDOW OPEN EASILY, STAY OPEN | WINDOW NOT CLOSING PROPERLY 4851 APARTMENT 1W KITCHEN | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
CARPETING | BROKEN LOOSE FLOOR TILES 4851 ENTRANCE FOYER | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
MICE/RODENTS | 4845 BSMT APARTMENT WITH MOUSE DROPPINGS. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
MICE/RODENTS | 4845 BSMT APARTMENT WITH MOUSE DROPPINGS. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
MICE/RODENTS | INSECTS - BEDBUGS - 4845 GARDEN APT | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING WINDOW SCREEN - 4851 APT 1W | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | BATHROOM TOILET CLOGED - 4851 APT 1W | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DECTECTOR MISSING - 4851 APT 1W | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST EXTERIOR WALL WITH ERODED MORTAR JOINTS AND SPALLED BRICK SECTIONS. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | PROVIDE FULL INTERIOR AND EXTERIOR ACCESS TO VERIFY SAFETY DETECTORS AND OCCUPANCY. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 4845 GARDEN UNIT ANTS | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THROUGHOUT ALL THE REAR PORCH STRUCTURE, VERY SLIPPERY GREEN SLIME, 4X4 COLUMNS ONLY NAIL, 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH ONLY TWO (2) 1/2" BOLTS IN DIAMETER, THROUGHOUT ENTIRE PORCH, - TOP FLOOR LEDGER BEAMS FASTENED TO BUILDING EXTERIOR WALLS WITH NAILS ONLY. - ALL FLOORS, ALL CONNECTIONS BETWEEN COLUMN AND BEAM MISSING BRACKETS. - BEAM AND COLUMN CONNECTION MISSING STEEL ANGLES / BRACKETS. UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - WEAK. GUARD RAILS ARE 30" TO 32" IN HEIGHT. PLANS AND PERMITS ARE REQUIRED TO REPAIR / REPLACE EXTERIOR PORCH(S) ALL CRITICAL CONNECTIONS, JUST NAIL, MISSING BRACKETS AND BOLTS, NAILS ARE POPING OUT AT MOST HANDRAILS IN THE ENTIRE PORCH, I CUT MY HAND WHILE CONDUCTION THE INSPECTION. - 6X6 COLUMNS NOT ATTACHED TO FOOTING. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | BUILDING THROUGHOUT - MISSING FIRE EXTINGUISHERS. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ILLUMINATE EXIT AREAS | THROUGHOUT ENTIRE BUILDING, - EMERGENCY LIGHTS NOT WORKING | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ROACHES | ROACHES INFESTED 4845 GARDEN APT | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | 4845 GARDEN UNIT RECEPALCES WITHOUT COVERS | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS OR MECHANICAL ROOMS. UNABLE TO VERIFY PREVIOUS INTERIOR VIOLATIONS. INSPECTION REQUIRED FOR PREVIOUS VIOLATION REMOVAL. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THROUGHOUT ALL THE REAR PORCH STRUCTURE, VERY SLIPPERY GREEN SLIME, 4X4 COLUMNS ONLY NAIL, 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH ONLY TWO (2) 1/2" BOLTS IN DIAMETER, THROUGHOUT ENTIRE PORCH, - TOP FLOOR LEDGER BEAMS FASTENED TO BUILDING EXTERIOR WALLS WITH NAILS ONLY. - ALL FLOORS, ALL CONNECTIONS BETWEEN COLUMN AND BEAM MISSING BRACKETS. - BEAM AND COLUMN CONNECTION MISSING STEEL ANGLES / BRACKETS. UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - WEAK. GUARD RAILS ARE 30" TO 32" IN HEIGHT. PLANS AND PERMITS ARE REQUIRED TO REPAIR / REPLACE EXTERIOR PORCH(S) ALL CRITICAL CONNECTIONS, JUST NAIL, MISSING BRACKETS AND BOLTS, NAILS ARE POPING OUT AT MOST HANDRAILS IN THE ENTIRE PORCH, I CUT MY HAND WHILE CONDUCTION THE INSPECTION. - 6X6 COLUMNS NOT ATTACHED TO FOOTING. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / NEAR ALLEY WAY / FRONT FACE EXTERIOR WALL - VERTICAL CRACK, OPEN MORTAR JOINT FROM PARAPET WALL SECTION. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | BUILDING THROUGHOUT - MISSING FIRE EXTINGUISHERS. | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |
ILLUMINATE EXIT AREAS | THROUGHOUT ENTIRE BUILDING, - EMERGENCY LIGHTS NOT WORKING | 4845 N MAGNOLIA AVE | PERIODIC | FAILED | View |