STOP/REMOVE NUISANCE | BASEMENT, 1ST, 2ND AND REAR ENCLOSED PORCH - EXCESSIVE ACCUMULATION OF PERSONAL ITEMS, JUNK AND DEBRIS - FIRE HAZARD. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | WEST ELEVATION - CANOPY - COLUMN MISSING AND BEING TEMPORARILY SHORED UP WITH ROOF SAGGING.CEILING WOOD PLANKS ROTTED AND MISSING.PERMIT REQUIRED FOR ROOF DANGEROUS AND HAZARDOUS.REPAIRS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION - 1 STORY STAIRS SYSTEM - 2X8 JOISTS ARE SPANNING 12FT AND ARE FASTENED TO RIM JOISTS WITH NAILS ONLY. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION /1 STORY ROOF COVERED WOODEN PORCH - 2X8 DECK JOISTS OVER SPAN APPROX. 12 FEET. STRINGERS NAILED ONLY AT TOP CONNECTIONS. TREADS HAVE SPLIT CRACKS AND WORN AND WEATHERED. PORCH ROOF COLUMNS[PILLARS] ARE ROTTED WITH SPLIT CRACKS AND OUT OF PLUMB. PLANS AND PERMIT REQUIRED FOR REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / 2ND FLOOR-WASHED OUT MORTAR.EAST ELEVATION / ENCLOSED PORCH SIDING-ROTTED WITH MISSING SECTIONS. | 2307 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION / 1 STORY ROOF COVERED WOODEN PORCH.LEDGER BEAM,ONLY FACE NAILED TO BUILDING.2X8 JOISTS SPAN 12 FEET.STRINGERS ONLY TOE NAILED AT TOP CONECTION,TREADS ARE SPLITTING.METAL RAILINGS ONLY 31 INCHES IN HEIGHT.PORCH ROOF COLUMNS ARE ROTTED AND LEANING OUT OF PLUMB.ROOF UNDER SIDE-LOOSE AND ROTTED BOARDS.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 2307 N AVERS AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / 2ND FLOOR-WASHED OUT MORTAR.EAST ELEVATION / ENCLOSED PORCH SIDING-ROTTED WITH MISSING SECTIONS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST ELEVATION - OVERGROWN WEEDS AND GRASS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION - TWO STORY ENCLOSED PORCH.EXTERIOR WALLS AND ASPHALT SIDING IS SAGGING AND LOOSE WITH ROTTED WINDOW SASHES AND FRAMES.PERMIT REQUIRED TO MAKE REPAIRS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | WEST ELEVATION - CANOPY - COLUMN MISSING AND BEING TEMPORARILY SHORED UP WITH ROOF SAGGING.CEILING WOOD PLANKS ROTTED AND MISSING.PERMIT REQUIRED FOR ROOF DANGEROUS AND HAZARDOUS.REPAIRS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION - 1 STORY STAIRS SYSTEM - 2X8 JOISTS ARE SPANNING 12FT AND ARE FASTENED TO RIM JOISTS WITH NAILS ONLY. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT 1ST FLOOR APARTMENT, 2ND FLOOR APARTMENT, FRONT INTERIOR STAIRWAY, REAR ENCLOSED PORCH AT TOP - WORKING SMOKE DETECTORS MISSING. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT, 1ST FLOOR APARTMENT - WORKING CARBON MONOXIDE DETECTORS - MISSING. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR ENCLOSED PORCH ROOF BROKEN AND LEAKING WATER - ROOF SHEATHING SECTION LOOSE, BROKEN AND COLLAPSED - DANGEROUS AND HAZARDOUS. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH STAIRS AND LANDINGS SEVERELY LEANING DOWN TOWARDS EAST (REAR). STAIRS ARE PULLING AWAY FROM BUILDING. 2ND FLOOR, FLOOR BROKEN, COLLAPSED AND MISSING SHEATHING - WATER DAMAGED FROM BROKEN ROOF AND BROKEN OUTSIDE WALLS. WALL SECTIONS AT EAST (REAR) BROKEN, SHIFTING AND COLLAPSING WITH WINDOWS LOOSE IN FRAMES. REAR ENCLOSED PORCH IS EXTREMELY DANGEROUS AND HAZARDOUS - PLANS AND PERMITS REQUIRED FOR REAR PORCH REPLACEMENT. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR BATHROOM CEILING BROKEN, FALLING AND COLLAPSED WITH MISSING PLASTER (DRYWALL), LARGE HOLE - PLUMBING LEAK FROM 2ND FLOOR. 1ST AND 2ND FLOORS WALLS AND CEILINGS PEELING PAINT. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR BATHROOM CEILING AND REAR ENCLOSED PORCH ROOF AND WALLS - LEAKING WATER - CAUSING WATER DAMAGE. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR APARTMENT HALL FLOOR BY BATHROOM TO KITCHEN SEVERELY BUCKLED - TRIP AND FALL HAZARD. PERMIT REQUIRED FOR FLOOR REPAIR. | 2307 N AVERS AVE | COMPLAINT | FAILED | View |