Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP ALL WORK BY ORDER OF CDOT | 1122 W CATALPA AVE | COMPLAINT | FAILED | View | |
OPEN TYPE VIOLATION | FIRE CAULK ELEVATOR MACHINE ROOM (EMR). | 1122 W CATALPA AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE GFI OUTLET IN EMR. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE SIGN AND SELF LOCKING HANDLE ON EMR DOOR. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE A GUARD ON HOISTWAY LIGHT FIXTURE. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | INSTALL CAMERA OR VISION PANEL TO VIEW ELEVATOR MACHINE. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE A SUMP COVER IN ELEVATOR PIT. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | FIRE SERVICE TO BE TESTED IN ITS ENTIRELY WHEN INSTALLATION IS COMPLETE. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | IDENTIFY CAR AT EACH LANDING DOOR FRAME AT UPPER LEFT CORNER. (18-30-010 AND 13-20-120) 100100238 | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | REGARDING CAR #2 INSTALLED UNDER PERMIT 100100238: 1)PROVIDE PERMANANT SIGNS ON ELEVATOR MACHINE ROOM (EMR) DOOR, EMR ACCESS PANELS, LANDING DOOR JAMBS, ETC. 2)REMOVE CABLE TELEVISION CHASE FROM EMR. ALSO RE-ROUTE VENT WIRING IN EMR SO NOT TO OBSTRUCT FRONT OF ELEVATOR CONTROLLER, 3)COMPLETE WIRING OF VENTILATION EQUIPMENT IN (EMR). 4)PROVIDE A DRAIN OR SUMP PUMP IN ELEVATOR PIT. 5) PROVIDE FINISHED CAB FLOOR AND FLUSH ENTRANCES, 6) REPROGRAM FLOW SWITCH AT 2ND FLOOR TO SEND CAR TO ALTERNATE (3RD FLOOR), 7) PROVIDE SINGLE MASTER KEY SWITCH AT LOBBY PANEL, 8) TEST EMERGENCY POWER WHEN PROVIDED. (18-30-010,13-20-120) 100100238 | 1122 W CATALPA AVE | PERMIT | PASSED | View |
NO ENTRY | 1122 W CATALPA AVE | PERIODIC | CLOSED | View | |
OWNER OR LICENSED CONTRACTOR | 1122 W CATALPA AVE | PERIODIC | CLOSED | View | |
OPEN TYPE VIOLATION | CODE VIOLATIONS NOT COMPLIED FROM 12/14/07: RE-ADDRESS FLOW SWITCHES TO SEND ELEVATORS TO CONNECT FLOORS. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | MAKE CORRECTIONS TO MASTER FIRE SERVICE PANEL. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | TEST EMERGENCY POWER. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE LINE OF SIGHT FROM CONTROLLER TO MACHINE. (OR CAMERA). | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | REMOVE SCREWS AND TEMPORARY ANCHORS IN HOISTWAY WALLS. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE GRAB RAILS AT TOP OF PIT LADDERS. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR MALFUNCTIONING EMERGENCY CAB LIGHTING - ALL ELEVATORS | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY 5 TEST, TAG AND DOCUMENT AS REQUIRED - ALL ELEVATORS | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MAINTAIN A CURRENT FIRE SERVICE MONTHLY TEST LOG IN SITE - ALL ELEVATORS | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MAINTENANCE CONTROL PROGRAM DOCUMENTS ON SITE - ALL ELEVATORS | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY LOCK AND SECURE MANUAL EMERGENCY BRAKE RELEASE LOCATED IN ELEVATOR MACHINE ROOM - ELEVATORS #1 AND #2 | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MAKE NECESSARY REPAIRS TO ELEVATOR #3 TO ENABLE ELEVATOR TO RUN SAFELY TO ALL LANDINGS (CANNOT GO PAST 7TH FLOOR AT TIME OF INSPECTION) | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
ARRANGE ANNUAL INSP. | ARRANGE ANNUAL INSPECTION OF ALL VENTILATION EQUIPMENT | 1122 W CATALPA AVE | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | REPAIR BROKEN FLUE ON WEST WALL | 1122 W CATALPA AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 1122 W CATALPA AVE | COMPLAINT | FAILED | View | |
GIVE VENT OPENINGS % FL. AREA | PROVIDE VENTILATION OPENING 12-(13-172) 25 SQ FT CLEAR OPENING TOP OF WINDOW MUST BE MIN G'-00 ABOVE FINISH FLOOR (ROOM 407-93") | 1122 W CATALPA AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | NEED TO REPLACE CORRODED FLUES INSIDE GARAGE (NEED REINSP) | 1122 W CATALPA AVE | PERIODIC | PASSED | View |
MAINTAIN MECH. VENT SYSTEM | MAKE SERVICE REPAIR TO GARAGE EXHAUST FANS #5,#6,#7,#11 | 1122 W CATALPA AVE | COMPLAINT | PASSED | View |
STOP ALL WORK. SEC. 13-12-050; 13-32-035; 13-32-080 | 1122 W CATALPA AVE | COMPLAINT | FAILED | View | |
OPEN TYPE VIOLATION | FIRE CAULK HOISTWAY AS NESSORY. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
REPAIR DOOR HARDWARE | UNIT # 1011 MAIN ENTRY DOOR - DEFECTIVE SELF-CLOSER.ALL UNITS ENTRY DOORS SHOULD HAVE WORKING SELF-CLOSERS. | 1122 W CATALPA AVE | COMPLAINT | FAILED | View |
ARRANGE ANNUAL INSP. | 1122 W CATALPA AVE | PERIODIC | FAILED | View | |
OPEN TYPE VIOLATION | REMOVE ELECTRICAL PIPING AND LARGE GAS LINE IN #3 ELEVATOR MACHINE ROOM. (A17.1A-1997 RULE 102.2 (D). | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | ADDITIONAL VIOLATIONS FOUND ON 11/22/10: PROGRAM EMERGENCY TELEPHONES TO OPERATE PROPERLY. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PERFORM CATEGORY 1 TESTS AS REQUIRED BY CODE. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR TOP OF HOISTWAY LIGHTING ON #3 ELEVATOR. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | CHECK PIT LIGHTING ON #2 ELEVATOR. | 1122 W CATALPA AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE (2) FIRE SERVICE KEYS IN LOBBY FIRE BOX #3 ELEVATOR. 18-30-010, 13-20-120. #100100238 | 1122 W CATALPA AVE | PERMIT | PASSED | View |
NO ENTRY | 1122 W CATALPA AVE | PERIODIC | FAILED | View | |
ARRANGE ANNUAL INSP. | 1122 W CATALPA AVE | PERIODIC | FAILED | View | |
ARRANGE ANNUAL INSP. | 1122 W CATALPA AVE | PERIODIC | PASSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 1122 W CATALPA AVE | PERIODIC | PASSED | View |