Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ELEVATOR CONTROL PANEL IN LOBBY | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL ALL PIT EQUIPMENT. IN ALL PITS | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL ALL DISCONNECT SWITCHES WITH VOLTAGE AND USE DESIGNATION. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | MECHANICALLY PROTECT ALL CABLE ROUTED THROUGH MACHINE ROOM. MUST BE IN METAL CONDUIT. SO CABLE IS NOT ALLOWED. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | USE INDUSTRY ACCEPTABLE WIRING METHODS WHEN INSTALLING CONDUIT RUNS THROUGH-OUT MACHINE ROOM. UTILIZE STRAPS, HANGERS, AND PIPE SUPPORTS. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
ARRANGE PERMIT INSP. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View | |
ARRANGE PERMIT INSP. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View | |
ENGAG LIC & BOND PLMBNG CNTRC | 18-29-106.1-106.2 PLUMBER OF RECORD FOR PERMIT 100599183 DID NOT DO TGHE WORK IN UNIT 20AN | 1212 N LAKE SHORE DR | COMPLAINT | FAILED | View |
REMOVE | ALL NEW PLUMBING INSTALLED BY A NON LICENSE PERSON IN UNIT 20AN ALL AREAS ALL ROOMS 18-29-106.2 | 1212 N LAKE SHORE DR | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | AFTER ALL PIPING IS REMOVED AND A NEW PLUMBING CONTRACTOR FOR PERMIT 100599183 IS PUT ON PERMIT | 1212 N LAKE SHORE DR | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PIT BELLS | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ELECTRICAL COVERS IN MACHINE ROOM, HOISTWAY(HOISTWAY CENTER), AND PITS | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SUMP PUMP IN SUMP HOLE | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SINGLE GANG GFCI OUTLET FOR SUMP PUMP | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE METAL SUMP HOLE COVER | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE LINE AND 110V HEAVY DUTY, LOCKABLE, FUSED DICONNECTS WITH LINE OF SIGHT FROM MACHINE | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | UPON COMPLETION OF MODERNIZATION SCHEDULE PHASE I & II, FAID RECALL, AND EMERGENCY POWER TESTING | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM ACCENDING CAR EMERGENCY BRAKING TEST DURING ACCEPTANCE TEST FOR ELEVATOR #1 | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SEAL UP TOP OF CINDER BLOCK HOISTWAY WALL AT TOP OF HOISTWAY | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GFCI OUTLETS IN MACHINE ROOM | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MECHANICAL PROTECTION ON ALL LIGHT BULBS IN MACHINE ROOM | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE METAL CODE DATA TAGS ON CONTROLLERS | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ELEVATOR CONTROL PANEL | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SINGLE GANG OUTLET FOR SUMP PUMP | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM ACCENDING CAR EMERGENCY BRAKING TEST DURING ACCEPTANCE TEST FOR ELEVATOR #1 & #2 | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE COUNTERWEIGHT RUNBY SIGNAGE IN ALL PITS. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL ALL PIT EQUIPMENT. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ADEQUATE PIT LIGHTING PRIOR TO FINAL. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL ALL DISCONNECT SWITCHES WITH VOLTAGE AND USE. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | RE: #4 CAR: RETEST GOVERNOR AND SAFETIES AND DOWN ETS WHEN HOIST CABLES ARE REPLACED.NO USE UNTIL THEN. | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | RE: #4 CAR: RETEST GOVERNOR AND SAFETIES AND DOWN ETS WHEN HOIST CABLES ARE REPLACED.NO USE UNTIL THEN. INSPECTOR FLEBBE COMPLIED 09/05/2017 | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE LINE AND 110V HEAVY DUTY, LOCKABLE, FUSED DICONNECTS WITH LINE OF SIGHT FROM MACHINE. ELEVATORS #1 & #2 | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SEAL UP TOP OF CINDER BLOCK HOISTWAY WALL AT TOP OF HOISTWAY ELEVATORS #1 & #2 | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE GFCI OUTLETS IN ALL MACHINE ROOMS ALL OUTLETS AND PROVIDE ONE CONVENIENT OUTLET PER EACH MACHINE AND CONTROL SPACE | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MECHANICAL PROTECTION ON ALL LIGHT BULBS IN MACHINE ROOMS | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE METAL CODE DATA TAGS ON ALL CONTROLLERS | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ADEQUATE PIT LIGHTING WITH BULB PROTECTION PRIOR TO FINAL. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CLEARLY IDENTIFY WITH CAR NUMBER ALL CONTROLLERS, DISCONNECTS, GOVERNORS, CROSS HEADS, TOE GUARDS, PITS... | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM EMERGENCY BRAKING ASCENDING CAR TEST PURSUANT TO ASME 17.1 2007 2.19.3 ELEVATORS #1, #2, & #3 | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | DO NOT USE ELEVATOR #3- UNTIL A SUBSTANTIAL AMOUT OF THE ABOVE VIOLATIONS HAVE BEEN ADDRESSED. THESE OUTSTANDING VIOLATIONS ARE TWO (2) YEARS PAST DUE. THERE WILL BE A 60 DAY RE-INSPECTION BEFORE A HEARING IS RECOMENDED | 1212 N LAKE SHORE DR | PERMIT | FAILED | View |
SEE INSPECTOR COMMENTS | SEE NOTICE # 12178 | 1212 N LAKE SHORE DR | PERMIT | CLOSED | View |
OPEN | 1212 N LAKE SHORE DR | PERMIT | FAILED | View | |
SEE INSPECTOR COMMENTS | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
SEE INSPECTOR COMMENTS | SEE NOTICE # 12207 | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
ARRANGE PERMIT INSP. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | CURRENTLY ELEVATORS NORTH #3, NORTH #4, AND SOUTH #5 ARE UNABLE TO RESPOND TO HALL CALLS AND ARE BEING OPERATED ON INDEPENDENCE OPERATION WITH OPERATORS PRESENT. | 1212 N LAKE SHORE DR | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLETE OUTSTANDING VIOLATIONS ON OPEN PERMIT # 100572184 SUBURBAN ELEVATORS LAST INSPECTION BY INSPECTOR # 534569 ON JULY 23, 2015. | 1212 N LAKE SHORE DR | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ELEVATORS #3,#4,AND #6 ARE OK TO OPERATE ON TEMPORARY PUBLIC USE. ALL ALARM BELLS, EMERGENCY PHONES, PHASE I, PHASE II, ELEVATOR CONNTROL PANEL, CAR DOOR RESTRICTORS, FIRE SPEAKERS, AND HALL CALLS ARE OPRATING PROPERLY. C.O.P. HALL CALLS ARE OPERATING BUT NO LATCHING LIGHTS. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CLEAN ALL SILLS, CARTOPS ,MACHINE ROOMS. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ADD HANDRAIL TO THE BACK & SIDE OF CARTOP | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | ADD TO MACHINE ROOM & ELEVATOR PITS MORE LIGHTS WITH GUARDS & GFI RECEPTACLE. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | LABEL ALL ELEVATOR EQUIPMENT,CARTOP,BUFFERS,INSIDE HOISTWAY DOORS MACHINES , DISCONNECT. MUST BE STENCILED. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PROPER VENTILATION IN ELEVATOR MACHINE ROOM | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL CAR IDENTIFICATION NUMBER ON ELEVATOR DOOR JAMB EVERY FLOOR | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | EXTEND PIT LADDER TO 48" ABOVE CAR SILL WITH NONE SLIP TREAD. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERMANENTLY MOUNT MAINLINE DISCONNECTS. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 1212 N LAKE SHORE DR | PERMIT | PASSED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | BUILD DEFLECTION AROUND WATER STACK IN MACHINE ROOM | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FINISH ELEVATOR CAB | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FIX EMERGENCY PHONE ON ELEVATOR #6 | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL SMOKE DETECTORS | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL 48" TOE GUARD. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE METAL PLATE ON THE BACK OF STEPS FOR SAFE ACCESS TO MACHINE ROOM. | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | TEST ALL SOMKE DETECTORS AND FIRE SERVIVEON CAR #6 | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE TRIPPING HAZARD TOP FLOOR CAR #6 | 1212 N LAKE SHORE DR | PERMIT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | OBTAIN A PERMIT TO RESTORE ELEVATORS AND HOISTWAYS DAMAGED IN FIRE AND WATER DAMAGE INCURRED ON THE NORTH TOWER 27TH FLOOR EFFECTING PASSENGER ELEVATORS NORTH #3, NORTH #4, AND SOUTH #5 (FRT OR SERVICE). | 1212 N LAKE SHORE DR | PERIODIC | PASSED | View |