Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | NORTHEAST WALL SECTION OF GARAGE - BROKEN , COLLAPSING , LOOSE , AND FRACTURED BRICKS AT ALLEY - DANGEROUS AND HAZARDOUS. EAST WALL - LOOSE , SPALLING , MISSING , BROKEN , AND SHIFTING BRICKS WITH WASHED OUT MORTAR. EAST WALL - WOOD SECTION - ROTTED WITH PEELING PAINT. EAST ASPHALT SIDING - BROKEN AND MISSING. WEST AND SOUTHWEST WALL - WASHED OUT MORTAR. SOUTH WALL - LOOSE AND MISSING SIDING [ FACADE OVER BRICK ] .PERMIT REQUIRED FOR MASONRY REPAIRS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR COPING | EAST WALL - COPING TILE SECTIONS - MISSING. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AT 2ND - WINDOWS - CRACKED AND BROKEN PANES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR ROOF STRUCTURE | EAST ROOF WOOD SHEATHING - ROTTED AND MISSING DECTIONS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
UNSANITARY CONDITIONS-ANIMALS | WEST SERVICE WALK - DOG FOULING. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST SERVICE WALK - CONCRETE - BROKEN , FRACTURED , AND MISSING. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | WEST AT SERVICE WALK - STORING BRICKS , BLOCKS , AND ROOFING MATERIAL. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQUIRED | WEST BLOCK 1 STORY ADDITION BUILT - SUBMIT PLANS AND OBTAIN PERMIT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH METAL GATE - PAD LOCKED - HAMPERING EGRESS. REAR EXIT DOOR FROM RESTAURANT - WITH METAL BAR AND METAL GATE LOCKED - HAMPERING EGRESS - DANGEROUS AND HAZARDOUS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | WEST AT 1ST - RESTAURANT EXHAUST VENT FAN IN FRONT OF 2ND FLOOR WINDOWS. WEST WALL AT GRADE - GRAFFITI. REAR AT 1ST FLOOR ROOF - FURNITURE STREWN ABOUT ON ROOF TOP AND ON TOP OF HEATING AND AIR CONDITIONING UNITS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR DOOR PROVIDING ROOF TOP ACCESS - GUARDRAIL MISSING AROUND ROOF PERIMETER. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
CHIMNEY | EAST CHIMNEY - WASHED OUT MORTAR WITH LOOSE PARGING MATERIAL. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE | FIRE SEPARATION BETWEEN 1ST FLOOR MERCANTILE AND THE RESIDENTIAL UNITS ABOVE HAS BEEN COMPROMISED. AT THE FIRST FLOOR ABOVE KITCHEN LOOSE DECORATIVE TIN TILE, EXPOSED WOOD FLOOR JOIST ABOVE AND LOOSE SECTIONS OF SHEET METAL USED FOR REPAIRS. (13-56-280) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | FIRE SEPARATION BETWEEN 1ST FLOOR AND BASEMENT AREA HAS BEEN COMPROMISED. DRYWALL SECTIONS WATER DAMAGED AND COLLAPSED IN ONE QUARTER OF BASEMENT. EXPOSED WOOD FLOOR JOIST ABOVE HAVE WATER DAMAGE AND NOTCHED TO ACCOMMODATE SUBSTANDARD REPAIR TO ABOVE JOISTS. OPEN ENTIRE CEILING FOR INSPECTION OF FLOOR UNDERNEATH BOTH BATHROOM, DISH WASHING ROOM, BAR AREA AND FRONT KITCHEN COUNTER. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE | EGRESS OBSTRUCTED: FRONT COUNTER AISLES BETWEEN 29 AND 34 INCHES IN WIDTH; BEHIND BAR AREA - AISLE 20 INCHES IN WIDTH; HALLWAY ENTRANCE LESS THAN REQUIRED 36 INCHES IN WIDTH. (15-4-880) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SUBMIT 2 COPY STRUCTURAL RPT | ENGINEER REPORT REQUIRED. BASEMENT CEILING STRUCTURE APPEARS TO BE WEAK AND SAGGING. SOME 1ST FLOOR JOIST AND BEAMS WATER DAMAGED, ROTTED AND OTHER CRACKED. SOME REPLACEMENT OF 6X6 BEAMS AND 4X4 COLUMN WITH MAKE-SHIFT FOOTINGS POURED IN BUCKETS. 4X4 COLUMNS BOWED AND CRACKED. 3X5 STEEL COLUMN RUSTED. SUBMIT ENGINEERING REPORT ON STABILITY OF 1ST FLOOR STRUCTURE SHORING INSTALLED WITHOUT PLANS OR PERMIT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | 1ST FLOOR MERCANTILE NEAR BAR AREA - COAT CLOSET AND STORAGE UNDERNEATH STAIRWAY. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR REAR ADDITION BETWEEN 1ST FLOOR MERCANTILE AND GARAGE. 15'X20' ADDITION ERECTED WITHOUT PLANS AND PERMIT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
GARAGE TO RESIDENTIAL-4HR SEP | SEPARATION BETWEEN 1ST FLOOR MERCANTILE AND GARAGE ADDITION IS LESS THAN 4 HOURS. 5/8 DRYWALL ONLY SEPARATING BUILDINGS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
ENCLSE FLOOR OPENINGS W/IHR FR | SECONDARY KITCHEN 1ST FLOOR MERCANTILE - OPEN PENETRATIONS AROUND DUCT WORK. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | REPAIR CEILINGS AND WALLS: DISH WASHING AREA, COLLAPSED CEILING AND UNFINISHED DRYWALL; DISH WASHING AREA BLACK SPORES ON WALLS AND CEILING; REAR GARAGE AND THROUGHOUT BASEMENT DAMAGED WALLS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | WALLS AND CEILINGS - DINING ROOM, SECONDARY KITCHEN, HALLWAY AND BATHROOMS - CRACKED, BROKEN AND MISSING PLASTER ON WALLS AND CEILINGS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | SURFACES, WALLS AND CEILING: DINING ROOM, HALLWAY, SECONDARY KITCHEN, DISH WASHING AREA AND REAR ADDITION - PEELING PAINT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | WOMEN'S BATHROOM - HOLE IN DOOR. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | WOMEN'S BATHROOM - DOOR LESS THAN REQUIRED 36 INCHES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
DOOR PROJECT INTO PUBLIC WAY | SECONDARY KITCHEN - DOOR SWING IN DIRECTION OF TRAVEL INTO HALLWAY. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
DOOR SWING IN DIR. OF TRAVEL | INSIDE DOOR OPENS IN DIRECTION OF TRAVEL AT FRONT ENTRANCE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | UNSANITARY CONDITIONS - MOLD ON CEILING IN HALLWAY, DISHWASHING ROOM WALL AND CEILING AND THROUGHOUT BASEMENT AREA. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - WEST AND EAST WALL SPALLING AND VERTICAL FRACTURES. OVERHEAD DOOR OFF TRACK, DRAFTY, FILLED WITH DEBRIS. DRYWALL CEILING BROKEN AND DAMAGED SECTIONS. HEATER INSIDE GARAGE WITH LARGE VEHICLE INSIDE - FIRE HAZARD. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REMOVE | REMOVE HEATER INSIDE GARAGE. (13-320-10) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | FENCE IN EXCESS OF 5 FT. IN HEIGHT. REDUCE OR OBTAIN PERMIT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHER EXPIRED 2013. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL, WEST ELEVATION - SPALLING BRICKS, MISSING BRICKS AND WASHED OUT MORTAR. SOUTH EAST ELEVATION WASHED OUT MORTAR AND SHIFTING BRICKS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION 2ND FLOOR - BROKEN WINDOW PANE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PARAPET & COPING | PARAPET AND COPING: SOUTH ELEVATION - BROKEN LIMESTONE COPING, AT WEST ELEVATION - LOOSE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL SYSTEM ABOVE GARAGE AREA NORTHEAST ELEVATION - LADDER DESIGN (IMPROPER). | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR FRAME | DOOR FRAMES - 2ND FLOOR EAST ELEVATION DOOR FRAMES DAMAGED WITH PEELING PAINT AS SEEN FROM EAST LOT. ADDITION DOOR BETWEEN MERCANTILE AND GARAGE, PEELING PAINT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR EAVES | FASCIA BOARD ROTTED AT REAR ADDITION WEST ELEVATION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | REAR ADDITION - GUTTERS AND DOWNSPOUT DAMAGED AND OR BENT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | HAND SINK REPLACE FLEX SUPPLIES WITH COPPER SUPPLIES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | HAND SINK WASTE, P.V.C. PLASTIC AT WALL, AND P.V.C. FITTING AT WALL. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | THREE COMPARTMENT SINK FRONT OF STORE BEHIND COUNTER, WASTE LINE INSTALLED IMPROPERLY WITH A PLASTIC TRAP. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | THE SMALL STAINLESS STEEL SINK WASTE TIED INTO THE THREE COMPARTMENT SINK WASTE LINE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | THE SMALL STAINLESS STEEL SINK - REPLACE THE FLEX WATER SUPPLIES WITH COPPER SUPPLIES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | THE FAUCET ON THE THREE COMPARTMENT SINK DOES NOT SHUT OFF COMPLETELY - REPAIR OR REPLACE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TRAP | KITCHEN IN BACK OF STORE, HAND SINK HAS PLASTIC TRAP, REPLACE WITH BRASS TRAP. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | KITCHEN SINK FAUCET - HANDLE FELL OFF WHEN TRIED TO TURN IT ON - REPAIR OR REPLACE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | KITCHEN SINK FAUCET HAS FLEX WATER SUPPLIES. REPLACE WITH COPPER TUBES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | DISH WASHING ROOM - THREE COMPARTMENT SINK FAUCET DOES NOT SHUT OFF - REPAIR OR REPLACE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | THREE COMPARTMENT SINK WASTE MADE WITH COPPER WATER TEES ON THEIR BACKS. REPIPE WITH APPROVED MATERIALS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INSTALL FIXTURES PROPERLY | THE LAUNDRY TUB, MISSING BACK LEGS, FIXTURE LEANING BACKWARDS ON A SEVERE ANGLE. INSTALL WITH REAR LEGS AND LEVEL. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INSTALL VENT PIPE FOR TRAP | LAUNDRY TUB, PROPERLY VENT TRAP, CURRENTLY "S" TRAP, NO VENT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | WOMEN'S BATHROOM - LAVATORY REQUIRES A GRID STRAINER OR PLUG. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TRAP | WOMEN'S BATHROOM - LAVATORY REMOVE P.V.C. TRAP, REPLACE WITH BRASS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | WOMEN'S BATHROOM - FLEX WATER SUPPLIES TO LAVATORIES, TOILETS - REPLACE WITH COPPER SUPPLIES. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TOILET SEAT | WOMEN'S BATHROOM - TOILET SEAT IS TOO LONG, INSTALL PROPER SEAT. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | MENS BATHROOM - NO HANDLE ON LAVATORY FAUCET - REPAIR OR REPLACE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | MENS BATHROOM - LAVATORY REQUIRES A GRID STRAINER OR PLUG. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | MENS BATHROOM - TOILET HAS FLEX SUPPLY, INSTALL COPPER SUPPLY. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REMV RARELY USED FIXTURE | BASEMENT - REMOVE ALL ABANDONED WATER, WASTE AND VENT PIPING. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INDIRECT CONN.FOR WATER SUPPLY | BASEMENT - INSTALL PROPER BACKFLOW DEVICE FOR HOSE CONNECTED TO REGULAR LAUNDRY TUB FAUCET. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PRV FLUE FOR HOT WATER HEATER | WATER HEATER - FLUE PIPE MISSING, REPIPE TO CHIMNEY (DANGEROUS AND HAZARDOUS) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REPIPE 2" P.V.C. WASTE LINE IN METALLIC PIPE AND TIE INTO 4" STACK. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
STOP LEAKING WATER | FIRST FLOOR MENS TOILET ROOM LEAKING INTO BASEMENT. STOP LEAKING WATER. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | FRONT OF BUILDING - 2" WASTE LINE RUN IN PVC WITHOUT ANY HANGERS FOR 12 FEET, RUN LINE WITH METALLIC PIPE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE ADEQUATE SUPPORT | INSTALL HANGERS ON 2" PIPING AT 8 FOOT INTERVALS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | TIE LINES IN WITH APPROVED MATERIALS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL IN REAR 1ST FLOOR STORE STORAGE ROOM AND BASEMENT AREAS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT FRONT, REAR STORE AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR CONDUITS APART AT FITTINGS THROUGHOUT BASEMENT AREA AND FOR ARMORED CABLE TO PORCELAIN PULL CHAIN LIGHT FIXTURE WITHOUT BOX IN 1ST FLOOR REAR STORAGE AREA - DANGEROUS AND HAZARDOUS CONDITION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES THROUGHOUT 1ST FLOOR STORE AREA. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGHOUT BASEMENT AREA AND PANELS LOCATED IN BASEMENT AREAS AND 1ST FLOOR STORE AREA - MISSING COVERS AND OPEN SLOTS IN PANEL - DANGEROUS AND HAZARDOUS CONDITION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION THROUGHOUT ALL BASEMENT AREAS AND STAIRWAYS TO BASEMENT AREAS, GARAGE INTERIOR AREAS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
ARMORED CABLE | REMOVE ALL DEFECTIVE ARMORED CABLE THROUGHOUT ALL BASEMENT AREAS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS, BOXES THROUGHOUT ALL BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
CORRODED CONDUIT & EQUIP | REMOVE ALL RUSTED, CORRODED CONDUITS, FITTINGS, BOXES THROUGHOUT ALL BASEMENT AREAS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
GROUND EQUIPMENT | PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5 FT. OF WATER METER OR VALVE - DANGEROUS AND HAZARDOUS CONDITION. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE SPLICE CORD TO HEAT LAMP DEVICE TO KEEP FOOD WARM. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
CORD TO FIXTURE | REMOVE ALL CORD CONNECTIONS TO LIGHT FIXTURES IN KITCHEN AREA. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | REPLACE ALL DEFECTIVE WIRING THROUGHOUT ALL BASEMENT AREAS AND 1ST FLOOR AREA - DANGEROUS AND HAZARDOUS CONDITION. (18-27-110.7) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE. (18-27-210.25) | 1812 W 47TH ST | COMPLAINT | PASSED | View | |
LIVE FRONT SWITCHBOARD | REPLACE LIVE FRONT DISTRIBUTION WITH DEAD FRONT TYPE IN BASEMENT AREA. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF LIGHT FIXTURES THROUGHOUT 1ST FLOOR STORE AREA WITHOUT PERMITS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | REAR EXTERIOR DOOR TO ADDITION - DRAFTY, TOO SMALL FOR OPENING. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | HAND SINK IN FRONT OF STORE, P.V.C. TRAP, REPLACE WITH BRASS. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
INSTALL FIXTURES PROPERLY | THE FAUCET ON THE THREE COMPARTMENT SINK IS NOT ATTACHED TO THE FIXTURE, SECURE FAUCET TO SINK. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR DOOR HARDWARE | REAR INTERIOR EXIT DOOR AT GRADE - HANDLES - BROKEN. SOUTH INTERIOR DOOR AT GRADE - CLOSER BROKEN. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | EAST WINDOW SILL AT WASHED OUT MORTAR. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | RESTAURANT INTERIOR AT REAR BY BATHROOMS - FIRE EXTINGUISHER -MISSING CHARGE. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
REMOVE | WOMEN'S AND MENS BATHROOMS - GRAFFITI ON WALLS. (7-28-065) | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PROVIDE TRAP FOR FIXTURE | THE SMALL STAINLESS STEEL SINK, NO TRAP. | 1812 W 47TH ST | COMPLAINT | PASSED | View |
PLASTIC EMERGENCY LIGHT NOT APPROVED FOR USE, ONLY METAL TYPE. (18-27-700.66-3) | 1812 W 47TH ST | COMPLAINT | PASSED | View |