The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCK ON WEST ELEVATION GATE, PAD LOCKS ON FRONT AND REAR GATES. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
REPAIR BALCONY | REAR BALCONIES WITH THE FOLLOWING DEFECTS,1) 2X 8 JOISTS OVER SPAN 10'22) 2X8 JOIST CONNECTIONS NAILED.3) 4X4 SUPPORT COLUMNS UNDER SIZED.4) 4X4 COLUMNS 8 INCH LAP JOINTS.5) 4X4 COLUMNS LAP JOINTS SCREWED.6) BEAM TO COLUMN CONNECTIONS NAILED.7) BEAM TO COLUMN CONNECTIONS NOTCHED.8) LEDGERS ANCHORED WITH CUT NAILS TO MASONRY WALL.9) SEVERAL COURSE OF BRICK STACKED AROUND 4X4 COLUMNS.10) GUARD RAILS MISSING BOTTOM SUPPORT RAIL (PICKETS FROM TOP TO BEAM).11) PLANS AND PERMITS REQUIRED FOR REPAIRS OR REPLACEMENT. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER MANEGMENT SIGN POSTED. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR TO VERIOFY DETECTORS. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
REPAIR BALCONY | REAR EXTERIOR 2 STORY BALCONY/ 4X4 COLUMNS- BEAMS, AND RIM JOISTS NOTCHED IN AT SAME LOCATION. 1/2 LAP JOINTS FASTENED WITH NAILS/ SCREWS ONLY. UNDERSIZED 2X8 BEAMS SPAN 11 FEET- WEAK, AND SAGGING. ALL DECK JOISTS FASTENED TO LEDGER BEAMS WITH TOE NAILS ONLY. LEDGER BEAMS FASTENED TO EXTERIOR WALL WITH CUT NAILS ONLY. PLANS, AND PERMIT REQUIRED TO REPLACE REAR EXTERIOR 2 STORY BALCONY. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT, AND REAR YARD GATES- PADLOCKS. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING- ENTRY REFUSED BY TENANT, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS, AND COMPLETE INSPECTION OF REAR EXTERIOR BALCONY AT 1ST, AND 2ND FLOORS. 2ND REQUEST FOR INTERIOR INSPECTION. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT & PLANS FOR BALONIES | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNER/MANAGER | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION/ SILLS- WASHED OUT MORTAR. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | WEST ELEVATION/ SIDE YARD GATE- DOUBLE KEY LOCK. | 8159 W ADDISON ST | COMPLAINT | FAILED | View |