Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FLAKY INTERIOR PAINT | EXTERIOR PAINTED AREAS FLAKING | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | WINDOWS DETERIORATED GLAZING | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR SILL | 11700 ENTRY DOOR BROKEN SILL | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR REAR PORCH ENCLOSURE | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NEITHER THE 1ST FLOOR CLUB NOR THE BASEMENT ROOMING UNIT AREA HAVE SMOKE DETECTORS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.8 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NEITHER THE 1ST FLOOR CLUB NOR THE BASEMENT ROOMING UNITS HAVE CARBON MONOXIDE DETECTORS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.9 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | THERE ARE NO FIRE EXTINGUISHERS AT THE 1ST FLOOR CLUB OR THE BASEMENT ROOMING UNITS.DANGEROUS AND HAZARDOUS.SECTION 14X5-504 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | ALL OD THE WINDOW LINTELS ARE RUSTED / WARPED. REPLACE WITH NEW. PERMIT REQUIRED.SECTION 14X-3-303 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | THE BASEMENT ROOMING UNIT AREA HAS NO EXIT ILLUMINATION.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
DOOR SWING IN DIR. OF TRAVEL | ALL OF THE 1ST FLOOR CLUB EXIT DOORS SWING INWARD AGAINST THE DIRECTION OF EGRESS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | THERE IS NO FIRE SEPARATION BETWEEN THE BASEMENT ROOMING UNITS AND THE 1ST FLOOR CLUB.DANGEROUS AND HAZARDOUS.SECTION 14X-6-605 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | THE 1ST FLOOR CLUB AND BASEMENT ROOMING UNITS ARE USING AN EXCESSIVE AMOUNT OF EXTENSION CORDS.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | 1 OF 2 REAR EXIT DOORS AT THE 1ST FLOOR CLUB HAS A KEY LOCK.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2.2 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | NEITHER THE 1ST FLOOR CLUB NOR THE BASEMENT ROOMING UNITS HAVE EXIT SIGNAGE.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | THE SOUTH EXTERIOT PORCH COLUMNS ARE SLIPPING OFF THEIR RESPECTIVE FOOTINGS. THE FOOTINGS THEMSELVES ARE OF AN UNDETERMINED DEPTH. UNSAFE CONDITION. PERMIT REQUIRED FOR REPAIRS.SECTION 14X3-303 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | THE BASEMENT ROOMING UNIT AREA (BELOW THE UNLICENSED CLUB) HAS MULTIPLE AREAS OF EXPOSED ELECTRICAL WIRING.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705. | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THE 1ST FLOOR CLUB HAS A BARRICADED REAR EXIT DOOR (1 OF 2 REAR EXIT DOORS). THE 2CD REAR EXIT DOOR IS OFF ITS' HINGES AND IS INOPERABLE. THE BASEMENT ROOMING UNITS HAVE TO (FRONT) EGRESS THROUGH THE 1ST FLOOR CLUB. THE BASEMENT ROOMING UNITS' REAR EXIT IS OBSTRUCTED BY A STAIR SYSTEM FOR THE ABOVE GRADE APARTMENTS WHERE THERE IS ONLY A 4' OPENING TO EGRESS THROUGH. THE CONDITION(S) OF EGRESS FOR BOTH SPACES IS EXTREMELY DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 1 OF 2 REAR EXIT DOORS AT THE 1ST FLOOR CLUB IS INOPERABLE / OFF ITS' HINGES.DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.13 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FL APT / FLOOR TILE - LIFTING UP IN FRONT ROOM.REAR ENCLOSED PORCH AND 1ST FL LANDING FLOOR TILE BROKEN AND MISSING. | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 1ST FL STORE / BATHROOM - WALLS AND CEILING WATER DAMAGE . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH ELEVATION / NUISANCE - DOG WASTE . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR / BASEMENT WINDOW - BROKEN | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | EAST AND NORTH ELEVATION / CANOPY -REQUIRED TO REPAIR EXTERIOR REPAIRS | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION / CHIMNEY CAP - MISSING | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | 2ND APT / ROOF - LEAKING IN FRONT ROOM | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | SOUTH ELEVATION / 2ND FL PLATFORM /ENCLOSED PORCH - 2ND FL FOOTING CRACKED.COLUMNS LEANING IN .LEDGER BOARD SCAB .JOIST UNDER SIZED SIDING LOOSE.PLANS AND PERMIT REQUIRED TO REPAIR EXTERIOR PLATFORM/ ENCLOSED PORCH | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | EAST ELVATION / BALCONY - 2ND FL .FOOTING CRACKED AND SINKING OPEN MORTAR JOINT .PERMIT REQUIRED TO REPAIR BALCONY | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | FRONT STORE / INTERIOR DOOR - BROKEN IN BATHROOM | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT STORE / DOUBLE KEY LOCK - STORM DOOR | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EAST ELEVATION / CORNICE - OPEN MORTAR JOINTS | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | FRONT 2ND FL APT/6 EXTENSION CORDS - USED TO POWER APT . 1 ELCT CORD FROM BASEMENT TO2ND FL APT . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR /INTERIOR STAIR - GRADE TO 1ST FL .HANDRAIL MISSING . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPL DEFECTIVE BATHROOM FLOOR | 2ND FL APT/ FLOOR JOIST - ROTTED . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THERE ARE NO PLANS, PERMITS, LICENSES OR ZONING CERTIFICATION FOR THE1ST FLOOR STRIP CLUB. THIS CLUB ADVERTISES ONLINE FOR TICKET SALES FOR ATTENDANCE. ALCOHOL / FOOD ARE SERVED / SOLD. ALSO, THERE ARE NO PLANS, PERMITS OR ZONING CERTIFICATE FOR THE (4) OCCUPIED BASEMENT ROOMING UNITS.SECTION 14A-4-401.1 | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST AND NORTH ELEVATION / LINTELS 1ST 2ND FL RUSTED AND BENT . PERMIT REQUIRED TO REPLACE LINTELS | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR / EXTERIOR STAIR - GRADE TO 1ST FL .WING WALL LARGE SECTION MISSING CEMENT | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND NORTH ELEVATION / EXTERIOR WALL - WASHED OUT MORTAR AND STEP CRACKS . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / WINDOW SILLS - OPEN MORTAR JOINT . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PARAPET | EAST ELEVATION / PARAPET - STEP CRACKS . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FL FRONT / CARBON MONOXIDE - MISSING . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT AND REAR /INTERIOR STAIR / SMOKE DETECTORS - MISSING | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | 2ND FL FRONT APT / CEILING LIGHT - 2ND BEDROOM HANGING OFF THE CEILING . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
CARPETING | SOUTH ELEVATION 2ND FL HALLWAY / CARPET - DIRTY . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | FRONT / 1ST FLOOR STORE /CLEAN - PILE OF ROTTED WOOD AND DRYWALL ON THE FLOOR . | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT 2ND FL APT / CEILING - FRONT ROOM WATER DAMAGE .1ST FL STORE / CEILING AND WALLS WATER DAMAGE. | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH ELEVATION / GUTTERS - RUSTED | 11700 S MICHIGAN AVE | COMPLAINT | FAILED | View |