The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | FRONT PORCH-1 LEVEL-MAIN PORCH BANISTER IS NAILED INTO BRICK COLUMNS AT BOTH ENDS.THIS DEFECTIVE CONECTION HAS BECOME LOOSE/DETACHED-THIS BANISTER MUST BE CONECTED W/ BOLTS.HARDWARE UPGRADE ONLY-NO PERMIT REQUIRED. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | KITCHEN WALLS - STAINS. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT - SEWER ODORS. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - MISSING SIDING. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS GRADE TO BASEMENT - MISSING SOUTH GUARDRAILS. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR LIVINGROOM CEILING - WATER LEAK. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH: UNDERSIZED 6"X6" BEAMS AND 2"X8" DECJ JOISTS SPAN 7'-5" AND 12'-11". COLUMN HALF LAP SPLICE CONNECTIONS ARE FASTENED WITH NAILS ONLY. COLUMN HALF LAP SLICE CONNECTION IS APROX 3" BELOW COLUMN FIRE CUT. GUARDRAILLS OVER 4'-0" ARE MISSING INTERMEDIATE SUPPORT. UNDERSIZED 2"X12" STRINGER HAS 14 STEPS AND ARE FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | BASEMENT FURNACE FLUE PIPE - HAS NEGATIVE PITCH.BASEMENT HVAC DUCTS - NOT INSULATED ON UNFINISHED BASEMENT. | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR APT., LAMINATED FLOOR - SEPARATING | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | STONE FOUNDATION WALLS - WASHED OUT MORTAR (INTERIOR SIDE.). | 7208 S ELLIS AVE | COMPLAINT | FAILED | View |