The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITHOUT A HANDRAIL FROM GRADE TO BASEMENT (2) COMPLETE THR GUARDON TOP OF THE RETAINING WALL UNDER PORCH (3) INSTALL WHEEL STEPS IN FRONT OF COLUMNS VEHICLE TOO CLOSE TO COLUMNS | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR FENCE | EAST AND SOUTH ELEVATIONS WITH WOOD FENCE ROTTING LEANING SECTIONS | 909 W BUENA AVE | PERIODIC | FAILED | View |
PARAPET | EAST PARAPET WITH CONCRETE COATING SPANNING SEE BUCKLED SECTION | 909 W BUENA AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH REPAIR BROKEN CONCRETE SERVICE WALK BROKEN SECTIONS | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS SECTIONS WITH OPEN MORTAR JOINTS AND STRESS CRACKS | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRACTURED EXTERIOR WALL - BETWEEN FIRST AND 2ND FLOOR EAST, STEP FRACTURES IN BRICK AND WINDOW SILL, AT DRIVEWAY. | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | OPEN MORTAR JOINT AT WINDOW SILLS VARIOUS LOCATION AT FRONT - EAST. | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION MASONRY WALL WITH FLAKING PAINT,FLAKING SKIM COAT. | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH FOOTINGS DETERIORATING,CRUMBLING,ERODING. SOME ALSO WITH FRACTURES.OBTAIN PERMIT.ARRANGE FOR FOOTING INSPECTION PRIOR TO BACK FILLING FOOTINGS THAT REQUIRE REPLACEMENT. | 909 W BUENA AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - MISSING | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST - EXTERIOR WALL - BUCKLING AT TOP | 909 W BUENA AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, COMMON AREAS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND CONDITIONS. | 909 W BUENA AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION ... 3RD FLOOR ... A VERY LARGE SECTION OVER PARGE COATED MORTAR (OVER EXISTING BRICKWORK) HAS BECOME DETACHED FROM THE BRICK WALL. A GREAT DEAL OF DEBRIS IS EVIDENT IN THE ADJOINING PUBLIC PARKING LOT WITH AN IMINENT HAZARDOUS OF A MUCH LARGER AMOUNT FALLING. DANGEROUS AND HAZARDOUS. PERMIT REQUIRED FOR REPAIRS. | 909 W BUENA AVE | COMPLAINT | PASSED | View |