The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE PERMIT TO CORRECT VIOLATIONS | 7507 S CARPENTER ST | COMPLAINT | FAILED | View | |
REPAIR INTERIOR WALLS/CEILING | ALL INTERIOR WALLS HAVE DAMAGED DRYWALL. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY HAS LOOSE AND MISSING MORTAR AND BRICK. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES ON EXTERIOR AND INTERIOR PROVIDE PERMIT TO CORRECT VIOLATIONS. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT , 1ST FLOOR, ATTIC MISSING CARBON MONOXIDE DETECTORS. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTICLES TO EASE USE OF EXTENSION CORDS FOR WASHER AND DRYER | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE ALL FLEXIBLE WATER LINES TO ALL FIXTURES AND ADD COPPER SUPPLIES | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | INSTALL SHOWER VALVE TRIM PLATE PROPERLY(CURRENTLY TO FAR FROM THE WALL) | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN A PLUMBING PERMIT TO CORRECT ALL PLUMBING VIOLATIONS | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
PROVIDE WATER MAIN GROUND CONDUIT, CONDUIT WITHIN 5 FEET OF WATER METER OR VALVE | 7507 S CARPENTER ST | COMPLAINT | FAILED | View | |
SUBMIT PLANS FOR PLUMBING PRMT | SUBMIT PLANS FOR REVIEW AND APPROVAL FOR FULL GUT AND REHAB TO THE DEPARTMENT OF BUILDINGS, WATER DEPARTMENT AND SEWAR DEPARTMENT | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | ADD AIR CHAMBERS TO LAUNDRY TUB AND WASHER WATER LINES IN THE BASEMENT | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING DEVICES AND ELECTRICAL EQUIPMENT THAT WAS INSTALLED WITHOUT PLANS PERMITS THROUGOUT THE BASEMENT, FIRST FLOOR, AND ATTIC AREAS, | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
EXPOSE FOR INSPECT APPROVAL | EXPOSE ALL PLUMBING FOR INSPECTION AND APPROVAL | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | RE-PIPE WASTE AND VENT TIE IN CONNECTIONS IN THE BASEMENT THAT CURRENTLY USE UNAPPROVED MATERIALS | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
INSTALLATION OF ELECTRICAL CONDUIT, BOXES,WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE BASEMENT, FIRST FLOOR, AND ATTIC AREAS WITH OUT ROUGH INSPECTION (ROUGH INSPECTION REQUIRES THAT ALL CEILINGS AND WALLS BE OPEN FOR INSPECTION) | 7507 S CARPENTER ST | COMPLAINT | FAILED | View | |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT ALL PLUMBING VIOLATIONS | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST WOOD PORCH HAS UNDERSIZED GUARDRAILS, SPLIT WORN STAIRS TREADS , INCORRECT RISER HEIGHTS, UNKNOWN FOOTINS. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | PROVIDE A VENT PIPE FOR THE FIRST FLOOR KITCHEN SINK TRAP | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST STAIRS GRADE TO BASEMENT MISSING GUARD/HANDRAIL. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST WOOD PORCH HAS UNDERSIZED GUARDRAILS, SPLIT WORN STAIRS TREADS , INCORRECT RISER HEIGHTS, UNKNOWN FOOTINS. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL EXTERIOR WALLS HAVE LOOSE AND MISSING MORTAR AND BRICK. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | WOOD PICKET FENCE OVER 5', REDUCE HEIGHT , REMOVE, OR OBTAIN A PERMIT. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT , 1ST FLOOR, ATTIC MISSING SMOKE DETECTORS . THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC HAS TWO VINYL CLAD DORMER WITH LOAD AND NON LOAD BEARING WALLS FORMING BEDROOMS AND A BATHROOM. BASEMENT HAS NON LOAD BEARING WALLS FORMING TWO BEDROOMS , ALL WORK CONSTRUCTED WITHOUT PROPER PLANS AND PERMIT. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE WITH VANDALIZED METER SOCKET | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST 1ST FLOOR WINDOW PANE BROKEN. | 7507 S CARPENTER ST | COMPLAINT | FAILED | View |