The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | SR-06-00143686-DEFICIENT AND IMPROPER FOOTINGS FRONT PORCH SYSTEM GRADE TO 2-STRINGERS IMPROPERLY CUT 1 TO 2 AND SCABBED GRADE TO 1, IMPROPER BEAM TO COLUMN CONNECTION-NOT ANCHORED. NO SIMPSON TIES, COLUMNS NOT LAP SPLICED PROPERLY OR BOLTED, LOOSE TREADS AND RISERS GRADE TO 2, LOOSE RAILINGS 2ND FLOOR DECKING DETERIORATED, ROTTED | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR GRADE TO 1 IMPROPER FOOTINGS, RAILINGS LOOSE AND IMPROPER HEIGHT, TREADS, RISERS AND DECKING ROTTED. FRONT-GRADE TO 1 LOOSE RAILINGS, MISSING PICKETS, ROTTED WOOD THRU-OUT | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | 25 FEET OF GUTTER MISSING AN WEST SIDE OF BUILDING | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALK CRACKED AND SINKING-PARTIALLY SUPPORTING FRONT PORCH COLUMN | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR REPAIRS TO STAIR SYSTEMS AND 2 STORY PORCH AND FOUNDATION-CONCRETE REPAIRS | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR INSPECTION | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 1744 W CORTLAND ST | PERMIT | FAILED | View | |
REPAIR DEFECTIVE FOUNDATION | WEST, FRONT FOUNDATION WALL SUPPORTING WEST COLUMNS FOR 2-STORY PORCH-BOWED FOUNDATION WALL, CRACKED AND DETERIORATED. | 1744 W CORTLAND ST | COMPLAINT | FAILED | View |