PIN: 25213210020000
Property Address: 11745 S UNION AVE
City - Zip: CHICAGO - 60628
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72330
2023 Tax District: 72003
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 49 Violations
Violation Inspector Comments Address Category Status View
PROPER SIZE GRD ELECTRODE COND INSTALL PROPER WATER PIPE GROUND 18-27-250.20 11745 S UNION AVE COMPLAINT FAILED View
ADD RECEPTACLES INSTALL ADDITIONAL KITCHEN COUNTER TOP RECEPTACLE 18-27-570.(10 E) 11745 S UNION AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPAIR DEFECTIVE BATHROOM RECEPTACLES 18-27-110.3 11745 S UNION AVE COMPLAINT FAILED View
INSTALL ILLUMINATION ILLUMINATE FRONT AND REAR ENTRY WAYS 18-27-720.6 11745 S UNION AVE COMPLAINT FAILED View
FIRE & WATER DAMAGE BATHROOM LITE FIXTURE AND FLEXIBLE CONDUIT DAMAGED DUE TO WATER LEAK FROM BATHROOM ABOVE 18-27-110.3 11745 S UNION AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NOT POSTED. 11745 S UNION AVE COMPLAINT FAILED View
RAT PROOF EXTERIOR DOOR LARGE GAP AT BOTTOM OF DOOR. 11745 S UNION AVE COMPLAINT FAILED View
RELOCATE SMOKE DETECTOR MISSING SMOKE DETECTOR AT FRONT STAIRWELL. 11745 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME DOOR FRAME BUSTED. 11745 S UNION AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE MISSING PEEPHOLES. 11745 S UNION AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE BARB Q GRILL ON PORCH AND JUNK AND DEBRIS. 11745 S UNION AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM IMPROPER FOOTING'S,IMPROPER BEAM TO COLUMN CONNECTIONS,UNDER SIZE BRACKETS,STRINGERS NOT CONNECTED PROPERLY,STRINGERS OVER CUT,OBTAIN PLANS AND PERMITS FOR REPAIRS. 11745 S UNION AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY BROKEN WALK. 11745 S UNION AVE COMPLAINT FAILED View
REPAIR FENCE BROKEN PANELS,6 FOOT WOODEN FENCE NO PERMIT. 11745 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO VERIFY COMPLAINTS OF MOLD AND INSPECT REAR PORCH - FENCED OUT. 11745 S UNION AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS FRONT INTERIOR STAIRWELL - SMOKE DETECTOR - OUT OF SERVICE. 11745 S UNION AVE COMPLAINT CLOSED View
PROVIDE FRONT ENTRY DOOR REMOVED [SEC. 13-196-641] 11745 S UNION AVE COMPLAINT CLOSED View
DEFECTIVE FIXTURES FRONT FOYER - LIGHT FIXTURE LOOSE AND HANGING. 11745 S UNION AVE COMPLAINT CLOSED View
EXPOSED WIRING FIXTURES FRONT FOYER - LOOSE LIGHT FIXTURE - EXPOSED WIRES 11745 S UNION AVE COMPLAINT CLOSED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR / BATHROOM - WALLS AND CEILING - WATER DAMAGE; KITCHEN - CRACKS ON WALLS. 11745 S UNION AVE COMPLAINT CLOSED View
STOP LEAKING WATER 1ST FLOOR / BATHROOM - WATER LEAKING THROUGH CEILING; 2ND FLOOR / KITCHEN SINK - WATER LEAKING UNDER THE COUNTER. 11745 S UNION AVE COMPLAINT CLOSED View
MICE/RODENTS ENTIRE BUILDING, INCLUDING BASEMENT, 1ST AND 2ND FLOOR - MICE INFESTATION. 11745 S UNION AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK 2ND FLOOR / BETWEEN KITCHEN AND BATHROOM AREAS - WOOD FLOOR SAGGING AND SHIFTING. PERMIT REQUIRED TO REPAIR STRUCTURAL MEMBERS OF THE FLOOR. 11745 S UNION AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS ENTIRE BUILDING, INCLUDING BASEMENT, 1ST AND 2ND FLOOR - SMOKE DETECTORS - MISSING. 11745 S UNION AVE COMPLAINT CLOSED View
RAT PROOF OPENINGS 2ND FLOOR - MOUSE HOLES AROUND THE BEDROOM AND HALL BASEBOARDS. 11745 S UNION AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWAY - LOOSE AND BROKEN WINDER TREADS - COVERED WITH CARPETING. 11745 S UNION AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH 2ND FLOOR / FRONT BEDROOM - WINDOW SASH LOOSE AND FALLING. 11745 S UNION AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR REAR BASEMENT TO GRADE STAIRWAY - MISSING HANDRAIL 11745 S UNION AVE COMPLAINT FAILED View
MICE/RODENTS ENTIRE BUILDING, INCLUDING BASEMENT, 1ST AND 2ND FLOOR - MICE INFESTATION. 11745 S UNION AVE COMPLAINT CLOSED View
RAT PROOF OPENINGS 2ND FLOOR - MOUSE HOLES AROUND THE BEDROOM AND HALL BASEBOARDS. 11745 S UNION AVE COMPLAINT CLOSED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWAY - LOOSE AND BROKEN WINDER TREADS - COVERED WITH CARPETING. 11745 S UNION AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR REAR BASEMENT TO GRADE STAIRWAY - MISSING HANDRAIL 11745 S UNION AVE COMPLAINT CLOSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE FRONT INTERIOR STAIRWELL AT 2ND. FL. [FURNICE INSTALLED] WITHOUT PERMIT. 11745 S UNION AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO FRONT INTERIOR STAIRWELL AT 2ND. FL. [FURNICE INSTALLED] OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 11745 S UNION AVE COMPLAINT CLOSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO FURNICE INSTALLED AT 2ND. FL. FRONT INTERIOR STAIRWELL OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 11745 S UNION AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH, WITH ROOF.-FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE BLOCK, ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES, FOUNDATION STATUS UNKNOWN. -COLUMNS /OVER NOTCHED WITH FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 4 INCHES APART. COLUMNS SPACED UP TO 9 FEET 9 1/2 INCHES APART. -ROOF BEAMS /ROTTED, SHIFTED, SAGGING, PULLING OUT OF POCKETS AT EXTERIOR WALL. NOT TIED BACK TO THE WALL INSIDE THE BEAM POCKET, MISSING STRAPS OR ANCHORS.-ROOF JOISTS /2X6 SPAN 9 FEET 9 1/2 INCHES, SPACED UP TO 24 INCHES O.C. (APART). -UPPER AND LOWER ENDS OF STRINGERS, FASTENED WITH NAILS OR SCREWS ONLY. -STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 8 3/4 INCHES TO 7 INCHES TO 6 1/2 INCHES. TREAD WIDTH NOT UNIFORMED, RANGING FROM 9 1/4 INCHES TO 8 INCHES TO 11 INCHES.-1ST. LANDINGS /ONLY UP TO 26 INCHES FROM NOSING TO BOTTOM GUARD RAIL SECTION.-MOST RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS OR SCREWS ONLY.PLANS AND PERMIT REQUIRED TO REPAIR. 11745 S UNION AVE COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] FURNICE INSTALLED IN FRONT INTERIOR STAIRWELL AT 2ND. FL. WITHOUT PERMIT. 11745 S UNION AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY. 11745 S UNION AVE COMPLAINT FAILED View
WINDOW OPEN EASILY, STAY OPEN 2ND FLOOR APARTMENT - MOST WINDOW SASHES SCREWED SHUT. 11745 S UNION AVE COMPLAINT CLOSED View
WINDOW REPAIR FOR AIR SEEPAGE 2ND FLOOR APARTMENT - WINDOWS DRAFTY, WITH AIR SEEPAGE. 11745 S UNION AVE COMPLAINT CLOSED View
DEBRIS, EXCESSIVE JUNK AND DEBRIS THROUGH-OUT EXTERIOR OF PROPERTY 14X-1-103 11745 S UNION AVE COMPLAINT FAILED View
SECURE RACEWAY STRAP AND SECURE ALL CONDUITS PROPERLY SPECIFICALLY ON THE EXTERIOR SOUTH ELEVATION OF THE BUILDING 11745 S UNION AVE COMPLAINT FAILED View
DEFECTIVE SERVICE REPAIR SERVICE RISER DUE TO CONDUIT IS SEPARATED IN THE COUPLING FITTING UNDER REAR PORCH D&H 11745 S UNION AVE COMPLAINT FAILED View
MAINTAIN WINDOW 1ST AND 2ND FLOOR WEST ELEVATION WINDOW BROKEN 14X-3-303.13 11745 S UNION AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT ELECTRICAL VIOLATIONS (14-4-404.6) 11745 S UNION AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR FRONT PORCH 14A-4-401.1 11745 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR UNVERIFIED OCCUPANCY DETECTORS OR LIVING CONDITIONS 14A-1-104.7 11745 S UNION AVE COMPLAINT FAILED View
LISTED FOR USE TEMP & LOCATION INSURE ALL ELECTRICAL CONDUITS AND EQUIPMENT IS LISTED FOR USE SPECIFICALLY ON THE WEST EXTERIOR ELEVATION REMOVE BOXES AND FITTINGS WHICH ARE NOT LISTED FOR DAMP AND WET LOCATIONS 11745 S UNION AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT WOODEN PORCH LOOSE/WEAK STAIRS LOOSE HANDRAIL,PLATFORM HAS EXCESSIVE PITCH, PORCH ROOF IS ROTTED AND SAGGING IN THE CENTER 14X-3-303.1.1 11745 S UNION AVE COMPLAINT FAILED View