Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:02 PM
PIN: 11304010100000
Property Address: 7511 N WINCHESTER AVE
City - Zip: CHICAGO - 60626
2023 Property Class:
2023 Township: -
2023 Neighborhood:
2023 Tax District:
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REAR PORCH - FOUNDATIONS UNKNOWN, IMPROPER BEAM TO COLUMN CONNECTION, 6X6 COLUMNS OVER NOTCHED AT LAP JOINT, RAILINGS NOT BOLTED TO BUILDING, TOP PORTION OF RAILINGS WRONG TYPE OF LUMBER USED, RAILINGS ARE LOOSE AND DEFLECT UNDER PRESSURE, 6X6 COLUMNS AT BEAM CONNECTION AT 3RD FLOOR HAVE SHIFTED, MISSING TIE STRAPS ON LOOKOUT BEAMS, STRINGERS NOT BOLTED TOO SUPPORTS, MISSING JOIST HANGERS, 2X8 JOIST OVERSPANNED, STAIR TREADS BOWED IN A FEW LOCATIONS, PLANS AND PERMITS REQUIRED. 7511 N WINCHESTER AVE PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION - WINDOW SILLS WITH OPEN MORTAR JOINTS. 7511 N WINCHESTER AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INSPECT REAR PORCHES 7511 N WINCHESTER AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR THREE STORY PORCH , STRINGERS INSTALLED BEHIND SINGLE HEADER CONNECTIONS, NAILED ONLY. PERMIT REQUIRED FOR REPAIRS. 7511 N WINCHESTER AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR 8 FT FENCE NO PERMIT OBTAINED. 7511 N WINCHESTER AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D SIGN POSTED. 7511 N WINCHESTER AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NO BUILDING REGISTRATION FROM 2006 THROUGH 2012. 7511 N WINCHESTER AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION - BROKEN WINDOW - BASEMENT. 7511 N WINCHESTER AVE PERIODIC FAILED View