NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCK. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | PADLOCKED. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIR SYSTEM- 6X6 COLUMNS ARE SET ON TOP OF UNDERSIZED, 8 INCH CONCRETE BASES; FOUNDATION STATUS IS UNKNOWN. WEST COLUMN IS CUT TOO SHORT; WOOD BLOCK SET ON TOP. SECOND FLOOR LANDING; BEAMS AND RIM JOISTS ARE SET ON TOP, AND ONLY TOE NAILED INTO THE COLUMNS. SYSTEM IS ONLY FASTENED TO THE EXTERIOR WALL OF THE FIRST FLOOR PORCH ENCLOSURE WITH 2X4 MEMBERS. FLIGHT OF STAIRS FROM (G) TO (MID-LANDING) SWAY UPON LOAD. WORN BUCKLED UP TREADS. ONLY 37 INCH HEIGHT GUARDRAILS. IMPROPER CONNECTIONS- MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. PLANS AND PERMIT REQUIRED FOR REPAIRS. EAST STAIRS FROM (G) TO (B)- MISSING HANDRAIL. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSED PORCH- COLUMNS ARE PULLING FROM THE BEAMS. SOUTH COLUMN SUPPORTING THE ROOF IS WORN WITH EXCESSIVE SPLITTING OF THE WOOD. ONLY PERMIT REQUIRED FOR REPAIRS. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK, TO AUTHORIZE ALTERATIONS (INSTALLATION OF REAR EXTERIOR STAIR SYSTEM AND REAR EXIT AT ATTIC) OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE THE REAR EXTERIOR STAIR SYSTEM FROM (G) TO (ATTIC), AND THE REAR EXIT INSTALLED AT THE ATTIC WITHOUT A PERMIT. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS OR PERMIT ON FILE FOR 2ND FLOOR DORMER ADDITION TO ATTIC OR TO BREACH ROOF AND WALL TO INSTALL DOOR AT REAR FOR ATTIC TO PROVIDE EXTERIOR ACCESS. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | 1. DRY ROTTED WOOD THRU-OUT.2. 6X6 COLUMNS RESTING ON UNDERSIZED CONCRETE PIERS OR CONCRETE SLAB.3. FOUNDATION STATUS UNKNOWN.4. 6X6 COLUMN CUT TOO SHORT AND SHIMMED TO SUPPORT BEAM.5. 4X4 COLUMNS AND WALKWAY RESTING ON ROOF.6. BEAM TO COLUMN CONNECTION INADEQUATE.7. 2X8 JOIST INADEQUATELY SUPPORTED AT BEAMS.8. STRINGERS INADEQUATELY SUPPORTED.9. STAIR TREADS LOOSE AND BROKEN.10. RISER HEIGHT INCONSISTENT, 1ST RISER HEIGHT GREATER THAN 7-3/4 INCHES.11. STAIR SYSTEM SWAYS WHEN LATERAL FORCES APPLIED.12. GUARDRAILS UNDER 42 INCHES IN HEIGHT, PICKETS NAILED TO OUTSIDE OF RAILINGS.13. HANDRAILS LOOSE AND DEFLECT.14. STAIRS TO BASEMENT MISSING HANDRAIL.15. PLANS AND PERMIT REQUIRED. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
CHIMNEY | WASHED OUT MORTAR. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REMOVE EXTENSION CORD RUNNING BASEMENT WINDOW TO ATTIC WINDOW. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NO PLANS OR PERMIT ON FILE FOR 2ND FLOOR DORMER ADDITION TO ATTIC OR TO BREACH ROOF AND WALL TO INSTALL DOOR AT REAR FOR ATTIC TO PROVIDE EXTERIOR ACCESS. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | 1. DRY ROTTED WOOD THRU-OUT.2. 6X6 COLUMNS RESTING ON UNDERSIZED CONCRETE PIERS OR CONCRETE SLAB.3. FOUNDATION STATUS UNKNOWN.4. 6X6 COLUMN CUT TOO SHORT AND SHIMMED TO SUPPORT BEAM.5. 4X4 COLUMNS AND WALKWAY RESTING ON ROOF.6. BEAM TO COLUMN CONNECTION INADEQUATE.7. 2X8 JOIST INADEQUATELY SUPPORTED AT BEAMS.8. STRINGERS INADEQUATELY SUPPORTED.9. STAIR TREADS LOOSE AND BROKEN.10. RISER HEIGHT INCONSISTENT, 1ST RISER HEIGHT GREATER THAN 7-3/4 INCHES.11. STAIR SYSTEM SWAYS WHEN LATERAL FORCES APPLIED.12. GUARDRAILS UNDER 42 INCHES IN HEIGHT, PICKETS NAILED TO OUTSIDE OF RAILINGS.13. HANDRAILS LOOSE AND DEFLECT.14. STAIRS TO BASEMENT MISSING HANDRAIL.15. PLANS AND PERMIT REQUIRED. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
CHIMNEY | WASHED OUT MORTAR. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REMOVE EXTENSION CORD RUNNING BASEMENT WINDOW TO ATTIC WINDOW. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | EXPOSED WIRES ABOVE ENTRY DOOR. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | 1. 4X6 COLUMNS RESTING ON SMALL CONCRETE BLOCKS SET IN CONCRETE SLAB.2. FOUNDATION STATUS UNKNOWN.3. BEAM TO COLUMN CONNECTION INADEQUATE.4. 4X6 LOOKOUT BEAMS OVER SPANNED.5. STRINGERS INADEQUATELY SUPPORTED.6. 2X8 JOIST INADEQUATELY SUPPORTED TO BEAM.7. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 2227 N MULLIGAN AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE- UNVERIFIED COMPLAINT OF: (SR#901878988); WATER SEEPING INTO THE FOUNDATION AND (SR#901941663); BUSTED PIPE, NO HEAT AT THE BASEMENT. UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRES ABOVE ENTRY DOOR. | 2227 N MULLIGAN AVE | COMPLAINT | FAILED | View |