The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR RE-INSPECTION | NO PRV`S | 150 W 127TH ST | PERMIT | PASSED | View |
ACCESS TO ROOF | BUILDING | 150 W 127TH ST | PERIODIC | FAILED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS WEDNESDAYS BETWEEN 8:00 AND 9:00 AM. | 150 W 127TH ST | PERIODIC | FAILED | View |
ACCESS TO ROOF | BUILDING | 150 W 127TH ST | PERIODIC | PASSED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS WEDNESDAYS BETWEEN 8:00 AND 9:00 AM. | 150 W 127TH ST | PERIODIC | PASSED | View |
FIRE EXTNGSHR REQ, RESDNTL | MISSING FIRE EXTINGUISHERS AT PUMP AND OR AT FRONT ENTRANCE DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSED BONDED PLUMBING CONTRACTOR | 150 W 127TH ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS THROUGHOUT DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
PRV FLOOR DRAIN WITH METAL STR | PROVIDE FLOOR DRAINS WITH SECURE METALLIC COVERS BY COFFEE BAR IN MANNER TO STOP TRIPPING HAZARD | 150 W 127TH ST | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | VENT PLUMBING SYSTEM FOR SINK DRAIN AT COFFEE STATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
SEAL DRAIN OPENING UNUSD FIXTR | SEAL DRAIN OPENING NOT USED BY COFFEE STATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE WATER SUPPLY LINES TO ALL PLUMBING FIXTURES THROUGHOUT LOCATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE TEMPERATURE MIXING VALVES FOR LAVATORIES AND HAND SINKS THROUGHOUT LOCATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
INDIRECT CONN.FOR WATER SUPPLY | PROVIDE TESTED AND APPROVED RPZ FOR INDIRECT CONNECTION FOR WATER SUPPLY DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
WORKING SPACE | ALL FOUR PANELS ARE MISSING THE CLEARANCE IN FRONT OF THE PANELS (DANGEROUS AND HAZARDOUS) | 150 W 127TH ST | COMPLAINT | PASSED | View |
CLOSE BOX OPENINGS | PANEL ON THE EAST WALL ARE MISSING BLANK (DANGEROUS AND HAZARDOUS) | 150 W 127TH ST | COMPLAINT | PASSED | View |
RESTORE EXIT AND EM | EM BATTERY PACKS ARE NOT FUNCTIONING AT ALL (DANGEROUS AND HAZARDOUS) | 150 W 127TH ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE GREEN EXTENSION CORD ABOVE DROP CEILING AND REMOVE CORDS GOING THROUGH THE CEILING TILES (DANGEROUS AND HAZARDOUS) | 150 W 127TH ST | COMPLAINT | PASSED | View |
PANEL SCHEDULES | LABEL PANEL PROPERLY | 150 W 127TH ST | COMPLAINT | PASSED | View |
ADD RECEPTACLES | NEED ADDITIONAL RECEPTACLES IN ORDER TO EASE THE USE OF CORDS GOING THROUGH THE CEILING TILES | 150 W 127TH ST | COMPLAINT | PASSED | View |
EXPOSED WIRING | EXPOSED WIRING AT SWITCH IN THE CEILING ABOVE THE COOLER AREA AND EXPOSED WIRING (DANGEROUS AND HAZARDOUS) ABOVE THE CEILING TILES IN THE MONEY COUNTING ROOM | 150 W 127TH ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | LIGHT ABOVE THE COOLER AREA IN THE STORAGE AREA IS MISSING COVER THE LIGHT IS NEAR BOXES (DANGEROUS AND HAZARDOUS) | 150 W 127TH ST | COMPLAINT | PASSED | View |
INSTALL GFCI'S | MISSING GFCI RECEPTACLES AT THE SINK AREAS | 150 W 127TH ST | COMPLAINT | PASSED | View |
ABANDONED EQUIPMENT | REMOVE ABANDONED LIGHT FIXTURE ABOVE THE CEILING IN THE MONEY COUNTING ROOM | 150 W 127TH ST | COMPLAINT | PASSED | View |
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS 14A-4-404.6 & 14A-4-404.6.1 | 150 W 127TH ST | COMPLAINT | PASSED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO VACANT RETAIL UNABLE TO VERIFY OCCUPANCY AND DETECTORS | 150 W 127TH ST | COMPLAINT | PASSED | View |
INTERIOR FINISH FIRERESISTANCE | EXPOSED STUDS 1X2 METAL STUDS THROUGHOUT STORAGE ROOMS INADEQUATE FIRE SEPARATION PROVIDE PLANS AND PERMIT OPENINGS/ PENETRATIONS BETWEEN THE 2 SPACES DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | CRACKED GLASS TRANSOM ABOVE DOOR | 150 W 127TH ST | COMPLAINT | PASSED | View |
KEEP FIXTUR CLEAN AND SANITARY | KEEP FIXTURES CLEAN AND SANITARY AT ALL TIMES THROUGHOUT LOCATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | OUT DATED FIRE EXTIGUISHERS THROUGHOUT DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE PLBG FIXTURE | REPLACE DEFECTIVE/BROKEN PLUMBING FIXTURE TOILET IN CUSTOMER BATHROOM | 150 W 127TH ST | COMPLAINT | PASSED | View |
SUBMIT PLANS FOR PLUMBING PRMT | SUBMIT PLANS FOR PLUMBING FOR APPROVAL AND STAMP | 150 W 127TH ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS THROUGHOUT DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
RESET LOOSE FIXTURE | RESET LOOSE HAND SINK FIXTURE HANGING FROM WALL NEAR 3 COMPARTMENT SINK | 150 W 127TH ST | COMPLAINT | PASSED | View |
INDIRECT CONN.FOR WATER SUPPLY | PROVIDE INDIRECT CONNECTION CHECK VALVE FOR COFFEE STATION WATER SUPPLY | 150 W 127TH ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | EXCESSIVE STORAGE IN CEILING FIRE HAZARD DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT FOR PLUMBING WORK TO BE PERFORMED | 150 W 127TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE WATER SUPPLY LINES AT COFFEE STATION | 150 W 127TH ST | COMPLAINT | PASSED | View |
INSTALL SUFFICIENT FIXTURES | PROVIDE HAND SINK AT FOOD PREP STATION BEHIND COUNTER | 150 W 127TH ST | COMPLAINT | PASSED | View |
PROVIDE | WOOD PLATFORM WITH UNKNOWN FIRE RATING 15.8.570 PROVIDE PLANS AND PERMIT | 150 W 127TH ST | COMPLAINT | PASSED | View |
PROVIDE | AISLE RESTRICTIONS THROUGHOUT 26"-30" 15.4.880, 15.4.900 DANGEROUS AND HAZARDOUS | 150 W 127TH ST | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | PROVIDE WATER METER ON WATER MAIN INSIDE OF BUILDING 11-12-670 | 150 W 127TH ST | COMPLAINT | PASSED | View |