The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | FRONT ELEVATION /PARAPET -LOOSE,SHIFTING BRICKS,WASHED OUT MORTAR JOINTS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | EAST ELEVATION,BUILDING I D SIGN,MISSING OWNERS ADDRESS. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST ELEVATION,FRONT YARD ,HIGH WEEDS. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION,STONE ENTRY WAY,FRACTURED LIMESTONE FACADE,NORTH ELEVATION,WASHED OUT MORTAR 1ST THRU 3RD FLOOR,REAR ENCLOSED PORCH ,TORN AND LOOSE SIDING. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | WEST ELEVATION,GARAGE WITH WASHED OUT MORTAR,ROOF WITH LOOSE AND PEELING ROLLED ROOFING. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,REAR ENCLOSED PORCH,MISSING SMOKE DETECTORS. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH,6 BY 6 COLUMNS SET ON CONCRETE PIERS,4 BY 4 COLUMNS SET ON SIDEWALK,FOUNDETION STATUS UNKNOWN,JOISTS ARE FACE NAILED ONLY,6 BY 6 BEAM 1ST FLOOR EAST ELEVATION IS ROTTED AT FIRE CUT,BEAM AND COLUMN CONNECTIONS ARE TOE NAILED ONLY,COLUMNS ARE BUTT JOINTED,RAILS AT 1ST FLOOR ARE ROTTED ,LOOSE AND PULLING,STRINGERS ARE FACE NAILED AT TOP CONECTION,TREADS ARE WORN,DECKING BOARDS ARE SPLITTING,PLANS AND PERMIT REQUIRED. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO MOST UNITS TO CHECK OCCUPANCY,DETECTORS. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - POSTED OWNER'S I.D. INCOMPLETE INFORMATION , MISSING COMPLETE MAILING ADDRESS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
CUT OR REMOVE HIGH WEEDS | SOUTH SIDE YARD , FRONT YARD ,HIGH WEEDS AND OVERGROWN SHRUBS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION,STONE ENTRY WAY,FRACTURED LIMESTONE FACADE,NORTH ELEVATION,WASHED OUT MORTAR 1ST THRU 3RD FLOOR, REAR ELEVATION SPALLED AND LOOSE BRICKS ,REAR ENCLOSED PORCH ,TORN AND LOOSE SIDING. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,REAR ENCLOSED PORCH,MISSING SMOKE DETECTORS. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR PARTLY ENCLOSED PORCH, 2X8 JOISTS OVER SPAN 10'2, 2X8 JOIST CONNECTIONS NAILED AT EVERY LEVEL. 4X6 COLUMNS AT GRADE RESTING ON CONCRETE BLOCKS, 4X6 COLUMNS AT GRADE OFF CENTER OF CONCRETE BLOCKS, FOUNDATION STATUS UNKNOWN.4X6 COLUMNS SHOWING SIGNS OF ROT .STRINGER CONNECTIONS TO EXTERIOR BALLOON FRAMING NAILED, STRINGER CONNECTIONS TO MASONRY WALL CUT NAILED (ONLY ON FIRST FLOOR), STRINGER CONNECTIONS ON SECOND AND THIRD FLOORS SEPARATING FROM MASONRY WALLS AND EXTERIOR WALL. 6X6 COLUMNS ON WEST ELEVATION BUT JOINT CONSTRUCTION THROUGH-OUT,6X6 COLUMNS SHOWING SIGNS OF ROT. HAND RAILS AT GRADE ROTTED AND DETACHED FROM SUPPORT POSTS. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. | 6018 N FRANCISCO AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | NO WORKING SMOKE DETECTOR PRESENT IN REAR PARTLY ENCLOSED STAIRWAY. | 6018 N FRANCISCO AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS / GRADE TO BSMT -MISSING GUARD RAIL. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT ELEVATION / WINDOW PANES -BROKEN,MISSING WINDOW PANES 3RD FLOOR. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY /SOUTH ELEVATION -WASHED OUT ,MISSING MORTAR. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND WEST ELEVATIONS /EXTERIOR WALLS -WASHED OUT MORTAR JOINTS,SPALLING BRICKS. FRONT ENTRY LIMESTONE /WASHED OUT MORTAR JOINTS, SPALLING LIMESTONE. PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION /WASHED OUT MORTAR JOINTS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR 3 STORY PORCH /ROTTED WOOD SECTIONS WITH PEELING PAINT. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING /INTERIOR -NO RESPONSE,NO ENTRY ,UNVERIFIED DETECTORS AND CONDITIONS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND WEST ELEVATIONS /EXTERIOR WALL - SPALLED BRICKS, WITH WASHED OUT MORTAR. FRONT ENTRY LIMESTONE - WASHED OUT MORTAR JOINTS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | REAR PORCH ROOF GUTTER - HOLES AT SEAMS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
PARAPET | FRONT ELEVATION /PARAPET - LOOSE, SHIFTED BRICKS, WITH WASHED OUT MORTAR. PERMIT REQUIRED FOR MASONRY REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION /WINDOW SILLS - WASHED OUT MORTAR. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | BUILDING THROUGHOUT - WINDOW FRAMES ROTTED, WITH PEELING PAINT. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION /CORNICE - WASHED OUT MORTAR JOINTS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR COPING | NORTH ELEVATION /COPING - WASHED OUT MORTAR JOINTS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT ELEVATION /WINDOW PANE - BROKEN, CRACKED. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR PORCH ROOF - ROTTED WOOD, WITH PEELING PAINT. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING HANDRAIL AND GUARDRAILS , FALL HAZARD . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH,6 BY 6 COLUMNS SET ON CONCRETE PIERS,4 BY 4 COLUMNS SET ON SIDEWALK,FOUNDATION STATUS UNKNOWN,JOISTS ARE FACE NAILED ONLY,6 BY 6 BEAM 1ST FLOOR EAST ELEVATION IS ROTTED AT FIRE CUT,BEAM AND COLUMN CONNECTIONS ARE TOE NAILED ONLY,COLUMNS ARE BUTT JOINTED,RAILS AT 1ST FLOOR ARE ROTTED ,LOOSE AND PULLING,STRINGERS ARE FACE NAILED AT TOP CONNECTION,TREADS ARE WORN,DECKING BOARDS ARE SPLITTING,PLANS AND PERMIT REQUIRED. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED ALL YEARS 1990 THROUGH 2016 . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR COPING | FRONT PARAPET COPING STONES OPEN MORTAR JOINTS BETWEEN STONES . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | FRONT ENTRY , DEADBOLT LOCKS NOT IN SERVICE , BUILDING NOT SECURE . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT ENTRY FOYER WATER DAMAGED CEILING , FLAKING PAINT AND PLASTER ON WALLS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS AND FLOORS , TORN ,LOOSE AND MISSING WINDOW SCREENS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS AND FLOORS WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS AND FLOORS , WOOD WINDOW SASHES AND WOOD WINDOW SASHES BEHIND STORM WINDOWS ROTTED WITH FLAKING PAINT AND PUTTY . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
CHIMNEY | SOUTH BRICK CHIMNEY SEVERELY DETERIORATED WITH LOOSE BRICKS AND OPEN MORTAR JOINTS . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BASEMENT DOOR ROTTED WITH FLAKING PAINT . FRONT ENTRY DOOR GLASS BROKEN AND CRACKED . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | WEST ELEVATION,GARAGE WITH WASHED OUT MORTAR,ROOF WITH LOOSE AND PEELING ROLLED ROOFING. WINDOWS , DOORS FLAKING PAINT AND PUTTY . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING HANDRAIL. | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH SERVICE WALK , FRACTURED , DISPLACED , SUNKEN AT COLUMN BASES BY REAR PORCH , TRIP AND FALL HAZARD . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | FRONT LIMESTONE CORNICE , OPEN MORTAR JOINTS BETWEEN LIMESTONES . | 6018 N FRANCISCO AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR OF BUILDING - INTERIOR STAIRWELL - TOP OF STAIR /SMOKE DETECTORS - NOT WORKING AT THE TIME OF INSPECTION. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION - CHIMNEY /BRICKS - SPALLING AND SHIFTING WITH SEVERELY WASHED OUT MORTAR. PERMITS REQUIRED FOR MASONRY REPAIRS TO CHIMNEY. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION - AROUND THIRD STORY WINDOWS /BRICKS - LOOSE, MISSING, AND FALLEN WITH SEVERELY WASHED OUT AND CRUMBLING MORTAR. DANGEROUS AND HAZARDOUS. ALL ELEVATIONS - EXTERIOR WALL /BRICKS - SPALLING AND CRUMBLING BRICKS WITH WASHED OUT MORTAR AND STEP CRACKS. PERMITS REQUIRED FOR REPAIRS TO EXTERIOR WALL. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS - WINDOWS /PANES - BROKEN, CRACKED AND MISSING. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
PARAPET | ALL ELEVATIONS - PARAPET /BRICKS - CRACKING SPALLING, HEAVING ,AND MISSING WITH SEVERELY WASHED OUT MORTAR AND STEP CRACKS THROUGHOUT. PERMITS REQUIRED FOR MASONRY REPAIRS TO PARAPET. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - ALL WINDOWS /FRAMES - WORN, WEATHERED AND CRACKING. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | FRONT ELEVATION - FRONT DOOR /LATCHING MECHANISM - NOT LATCHING PROPERLY. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION - DECORATIVE CORNICE ABOVE ENTRY /CORNICE - WASHED OUT JOINTS WITH CRUMBLING MORTAR. | 6018 N FRANCISCO AVE | COMPLAINT | FAILED | View |