The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - MINOR [MALE] CHILD HOME - NO ENTRY.UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF SR#16-2847387 - ILLEGAL CONVERSION.UNABLE TO INSPECT INTERIOR STAIRWAY; REAR YARD /2 [TWO] DOGS OUT. UNABLE TO INSPECT REAR PORCH; | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| REPLACE D&H PORCH | FRONT ELEVATION /1 STORY WOOD PORCH WIRH ROOF.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE BLOCKS, WITH NO BASES; FOUNDATION STATUS UNKNOWN; FOUNDATIONS /COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN; COLUMNS /SETTLED. NOTE: WOOD PORCH - SETTLED AT EXTERIOR WALL - BACK PITCHED - CREATING A TRIP HAZARD - EXISTING CONCRETE STOOP MEETS WOOD DECK BOARDS.LEDGER BEAMS /NOT ATTACHED TO BUILDING EXTERIOR WALL OR EXISTING CONCRETE STOOP.DECK JOISTS /UNDERSIZED 2X6 DECK JOISTS SPAN 8 FEET 10 INCHES; DECKING /DECK BOARDS UNEVEN - CREATING A TRIP HAZARD - EXISTING CONCRETE STOOP MEETS WOOD DECK BOARDS. RAILINGS /GUARD RAILING SECTIONS ONLY 33 INCHES HIGH. ALL RAILING SECTIONS FASTENED TO COLUMNS WITH NAILS /SCREWS ONLY; RAILINGS NOT FASTENED TO EXTERIOR WALL.ROOF [AT SOUTH] SAGGING, SUPPORTED WITH 2X4 ANGLED BACK TO BUILDING, FASTENED WITH NAILS/SCREWS ONLY.PLANS AND PERMIT REQUIRED. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| REPAIR STOOP | FRONT ELEVATION /CONCRETE STOOP, METAL GUARD/STAIR RAILS WITH METAL COLUMNS;RAILINGS /GUARD RAILING SECTIONS ONLY 30 1/2 INCHES HIGH - NOT FASTENED TO EXTERIOR WALL, LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP RAILS PULLING; SOUTH GUARD RAIL SECTION - MISSING; METAL COLUMNS TO ROOF CONNECTION NOT FASTENED, OUT OF PLUMB, LEANING;PERMIT REQUIRED. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| REPAIR FENCE | REAR PERIMETER /6 FEET WOOD FENCE ¿ NO PERMIT OBTAINED.PERMIT REQUIRED. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO ENTRY, UNABLE TO VERIFY DETECTOR, OCCUPANCY AND CONDITION AT BASEMENT. ATTIC AND REAR COACH HOUSE. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| CARB MONOX DETECT IN RESID | FRONT HOUSE NO CARBON MONOXIDE DETECTOR. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| REPAIR/REPLACE SMOKE DETECTORS | FRONT HOUSE SMOKE DETECTOR OUT OF ORDER. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLAN AND PERMIT FOR FRONT ATTACH DECK, FRONT RAIL 36" HIGH, 18"SPACE BETWEEN ORIGINAL PORCH AND DECK. | 6327 S KENNETH AVE | COMPLAINT | FAILED | View |