REPAIR PORCH SYSTEM | REAR PORCHES 6X6 AND 4X4 COLUMNS ON CONCRETE BLOCKS OR CONCRETE SLAB, FOUNDATION STATUS UNKNOWN 6X6 COLUMNS STACKED 6X6 COLUMN OVERNOTCHED AT BEAM AT COLULN CONNECTION, 4X4 COLUMNS'S USED FOR SUPPORT OVER 12 FEET HIGH, BEAM TO COLUMN CONNECTION INADEQUATE LOOKOUT BEAMS MISSING TIE STRAPS, STRINGERS INADEQUATELY SUPPORTED, STAIR TREADS TOO SMALL, 2X8 JOIST SPAN 12 FEET, MISSING JOIST HANGERS, PLANS AND PERMIT REQUIRED | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION/CORNICE WASHED OUT MORTAR | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES 6X6 AND 4X4 COLUMNS ON CONCRETE BLOCKS OR CONCRETE SLAB, FOUNDATION STATUS UNKNOWN 6X6 COLUMNS STACKED 6X6 COLUMN OVERNOTCHED AT BEAM AT COLULN CONNECTION, 4X4 COLUMNS'S USED FOR SUPPORT OVER 12 FEET HIGH, BEAM TO COLUMN CONNECTION INADEQUATE LOOKOUT BEAMS MISSING TIE STRAPS, STRINGERS INADEQUATELY SUPPORTED, STAIR TREADS TOO SMALL, 2X8 JOIST SPAN 12 FEET, MISSING JOIST HANGERS, PLANS AND PERMIT REQUIRED | 6201 N GLENWOOD AVE | PERIODIC | PASSED | View |
REPAIR CORNICE | SOUTH ELEVATION/CORNICE WASHED OUT MORTAR | 6201 N GLENWOOD AVE | PERIODIC | PASSED | View |
INT WALL/CEILING CHIP PLASTER | 6201-6207-6211 VESTIBULE ABOVE RADIATORS PEELING PLASTER | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOINTS EAST ELEVATION | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | INCOMPLETE MANAGEMENT SIGN NO ADDRESS | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | GRADE TO BASEMENT REAR NO HAND RAIL | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 6201 1ST FL MISSING BANISTER, 6211 GRADE TO 1ST LOOSE STAIR THREAD WINDERS | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 6201-6207-6211 VESTIBULE ABOVE RADIATORS PEELING PLASTER | 6201 N GLENWOOD AVE | PERIODIC | PASSED | View |
CHIMNEY CAPPING | EAST ELEVATION/CHIMNEY MISSING CAP | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | SOUTH AND WEST ELEVATION @ 2ND, 3RD FLOOR WINDOW LINTELS - RUSTED BENT SAGGING, WITH GAPS ABOVE IT. NOTE: MOST WINDOW LINTELS CAPPED WITH METAL WRAP CAUSING PREMATURE FAILURE. REMOVE METAL WRAP. PLANS AND PERMIT REQUIRED TO REPLACE LINTELS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION /EXTERIOR WALL - OPEN MOTAR JOINTS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. YARD GATE LOCKED. UNABLE TO INSPECT REAR EXTERIOR PORCHES. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | EAST ELEVATION/CHIMNEY MISSING CAP | 6201 N GLENWOOD AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION /EXTERIOR 3STORY WOOD PORCH SYSTEM - CONCRETE FOUNDATION SPALLED AND CRUMBLING AT MULTIPLE LOCATIONS; METAL COLUMN ANCHORS RUSTED AND DETERIORATING AT MULTIPLE LOCATIONS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
PARAPET | NORTH ELEVATION /PARAPET - WASHED OUT MORTAR JOINT AT FRONT TO SIDE WALL CONNECTION. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION /EXTERIOR WALL - OPEN MOTAR JOINTS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /MOST APARTMENTS - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | SOUTH AND WEST ELEVATION @ 2ND, 3RD FLOOR WINDOW LINTELS - RUSTED BENT SAGGING, WITH GAPS ABOVE IT. NOTE: MOST WINDOW LINTELS CAPPED WITH METAL WRAP CAUSING PREMATURE FAILURE. REMOVE METAL WRAP. PLANS AND PERMIT REQUIRED TO REPLACE LINTELS. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. YARD GATE LOCKED. UNABLE TO INSPECT REAR EXTERIOR PORCHES. | 6201 N GLENWOOD AVE | PERIODIC | FAILED | View |