Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | SOUTH ELEVATION/ PARAPET WALL- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH ELEVATION/ CHIMNEY- SPALLING BRICKS, WITH WASHED OUT MORTAR. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | FRONT EXTERIOR PORCH CANOPY- PEELING PAINT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT EXTERIOR PORCH/ WING WALLS- FRACTURED MASONRY, WITH WASHED OUT MORTAR. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT EXTERIOR STAIRWAY/ BASEMENT TO GRADE/ GUARD RAIL- MISSING. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH ELEVATION/ BASEMENT WINDOW FRAMES- PEELING PAINT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS. UNABLE TO INSPECT INTERIOR STAIRWAYS, AND REAR ENCLOSED PORCH. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | OPEN JOINTS, FRACTURES, VERTICAL FRACTURES, EXPOSED WOOD TRIM, LOOSE PAINT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | BROKEN CONCRETE, BASEMENT ENTRY WAY. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | OPEN JOINTS, CONCRETE BLOCK UNFINISH, RUSTED LINTELS. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEP HOLES. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | TREADS, LOOSE, AND WEAK, 1/2 INCH GAP AT 2ND. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | PARTIAL ENTRY. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR, NOT BEEPING. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS INFORMATION POSTED. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | CONCRETE BLOCK GARAGE BUILT APPROXIMATELY 22X22X 17FT HIGH, NO PERMIT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | TREADS, LOOSE, AND WEAK, 1/2 INCH GAP AT 2ND. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR, NOT BEEPING. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | CONCRETE BLOCK GARAGE BUILT APPROXIMATELY 22X22X 17FT HIGH, NO PERMIT. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | NO CARBONMONOXIDE, DETECTOR IN BASEMENT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS, AND PERMITS TO AUTHORIZE ALTERATIONS TO BASEMENT APARTMENT OR RESTORE TO ORIGINAL CONSTRUCTION, FRONT BASEMENT WALL BREACHED, AND DOOR INSTALLED, INTERIOR REHAB, LAUNDRY ROOM ON REAR PORCH ,NEW FURNACES, ALL APARTMENTS, NO PERMIT. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE, ALL PARTITON WALLS, KITCHENS, ELECTRICAL, PLUMBING, BATH ROOM, INSTALLED IN BASEMENT WITH OUT PERMITS, AND RESTORE TO ORIGINAL CONSTRUCTION. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | OPEN JOINTS, FRACTURES, VERTICAL FRACTURES, EXPOSED WOOD TRIM, LOOSE PAINT. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | PLANS, AND PERMIT REQUIRED, NEWLY BUILT ENCLOSED PORCH, FOOTINGS UNKNOWN, COLUMNS UNDER SIZE 4X4, OVER 12FT, 8 INCH SPLICES, 6X6 COLUMNS OVER NOTCHED, TRIPPLE 2X8 BEAM NOTCHED INTO COLUMN, NO STEEL STRAPS, MISSING JOIST HANGERS, GAPS BETWEEN COLUMN, AND BEAM CINNECTIONS, STRINGERS NAILED TO WALLS, STAIR LANDINGS IMPROPER WIDTH 32 INCHES, MISSING BOLTS, VARIOUS LOCATIONS, UNEVEN RISER HEIGHTS. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | PARTIAL ENTRY. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | NO CARBONMONOXIDE, DETECTOR IN BASEMENT. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | BROKEN CONCRETE, BASEMENT ENTRY WAY. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS INFORMATION POSTED. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR / REBUILD SHED | OPEN JOINTS, CONCRETE BLOCK UNFINISH, RUSTED LINTELS. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEP HOLES. | 2057 N KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | OPEN JOINT ON LANDING, NO HANDRAIL GROUND TO BASEMENT. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT, BASEMENT WELL, NO GUARD RAILS. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PLANS, AND PERMIT REQUIRED, NEWLY BUILT ENCLOSED PORCH, FOOTINGS UNKNOWN, COLUMNS UNDER SIZE 4X4, OVER 12FT, 8 INCH SPLICES, 6X6 COLUMNS OVER NOTCHED, TRIPPLE 2X8 BEAM NOTCHED INTO COLUMN, NO STEEL STRAPS, MISSING JOIST HANGERS, GAPS BETWEEN COLUMN, AND BEAM CINNECTIONS, STRINGERS NAILED TO WALLS, STAIR LANDINGS IMPROPER WIDTH 32 INCHES, MISSING BOLTS, VARIOUS LOCATIONS, UNEVEN RISER HEIGHTS. | 2057 N KOSTNER AVE | COMPLAINT | FAILED | View |