PROVID SELF CLSING SCREEN DVCE | SR#07-00011078 EAST STORM DOOR: MISSING CLOSER | 2153 N BELL AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | EAST STORM DOOR: DOES NOT CLOSE PROPERLY | 2153 N BELL AVE | COMPLAINT | PASSED | View |
DEMO DEBRIS | DEMO DEBRIS IN REAR | 2153 N BELL AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS TO ALLEY: MISSING HANDRAIL | 2153 N BELL AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 1ST FL: MISSING CARBON MONOXIDE DETECTOR (PREVIOUS VIOLATION FROM 08-09-05) | 2153 N BELL AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR TO VERIFY OCCUPANCY & TO VERIFY DETECTORS | 2153 N BELL AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION: WINDOW TO WEST OF DOORWAY BROKEN GLASS | 2153 N BELL AVE | COMPLAINT | PASSED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL PERMIT IS OBTAINED SEC (13-12-080) AND (13-32-035) | 2153 N BELL AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | DEMO; REMOVAL OF PARTITIONS IN BASEMENT FRONT APARTMENT FOR RELOCATION | 2153 N BELL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | SR#06-00172884 BASEMENT-FRONT REFUSED EVERY,TO INTERIOR FOR INSPECTOR. POSSIBLE CONVERSION FROM 2 UNITS. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1 DECK ROTTED AND LEANING IN TOWARDS BUILDING; RAILING DETERIORATED AND LEANING (OUT OF PLUMB); TREADS INSUFFICIENT SIZE, ROTTED JOIST TO BUILDING IMPROPER CONNECTION; BEAM TO JOIST IMPROPER CONNECTION;GRADE TO BASEMENT CONCRETE STEPS DETERIORATED, HOLE; ALLEY STEPS TO GRADE NO RAILS. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK AND DEBRIS IN FRONT YARD. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL-OPEN MORTAR JOINTS, ALL WALLS, SOUTH SIDE ELEVATION SIDING FALLING OFF BUILDING AT SIDE ENTRANCE; NORTH SIDE ELEVATION SIDING FILLING OFF VARIOUS LOCATIONS. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE PATIO REAR YARD TO PORCH CRACKED CONCRETE, SINKING. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR GRADE TO 1-RAILINGS INSUFFICIENT HEIGHT AND ROTTED, LEANING; TREADS ROTTED, COLUMNS BOWED, LEDGER BOARD NOT PROPERLY ATTACHED TO BUILDING; INSUFFICIENT | 2153 N BELL AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | FRONT BASEMENT WINDOW BROKEN; 2ND FLOOR REAR WINDOW BOARDED UP. | 2153 N BELL AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | SOUTH ELEVATIONS CENTER DOOR: MISSING DEADBOLT | 2153 N BELL AVE | COMPLAINT | PASSED | View |